Victor Emmanuel de Oliveira Gomes
Victor Emmanuel de Oliveira Gomes has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Vitor Camargo Nardelli
Center for Embedded Devices and Research in Digital Agriculture (CEDRA) (EMBRAPII/SENAI-RS), São Leopoldo 93025-753, Brazil
3 shared publications - Alex Krummenauer
SENAI Innovation Institute for Sensor Systems (ISI-SIM), São Leopoldo 93025-753, Brazil
2 shared publications - Arthur dos Santos Barbosa
SENAI Innovation Institute for Sensing Systems (ISI-SIM), São Leopoldo 93025-753, Brazil
1 shared publication - Douglas Bergamo
SENAI Innovation Institute for Sensor Systems (ISI-SIM), São Leopoldo 93025-753, Brazil
1 shared publication - Francisco Erberto de Sousa
SENAI Innovation Institute for Sensing Systems (ISI-SIM), São Leopoldo 93025-753, Brazil
1 shared publication - Gilberto da Silva e Silva
Center for Embedded Devices and Research in Digital Agriculture (CEDRA) (EMBRAPII/SENAI-RS), São Leopoldo 93025-753, Brazil
1 shared publication
Latest Publications
- Open Access
CHIMA: Design and Evaluation of a Lightweight Cryptographic System for IoT Applications
Resource-constrained Internet of Things (IoT) devices motivate the investigation into cryptographic designs with measurable implementation costs. This work presents CHIMA (Cryptography cHaotic lIghtweight systeM and Authentication), an experimental system combining a key generator based on chaotic states, a Feistel cipher using the AES substitution box and a keyed bit permutation, and a Lesamnta-LW-based ciphertext check. Logistic, H’enon, and Lorenz systems are examined for key generation, and cipher variants with 64-bit and 128-bit blocks are evaluated. The study reports functional tests, avalanche measurements, NIST statistical tests, and implementation measurements on Arm Cortex-M0+, Cortex-M33, and Cortex-M7 microcontrollers. Controlled WiFi/MQTT and LoRa experiments assess communication interoperability. The results show that the chaotic key generator achieved high entropy and passed all NIST statistical tests, indicating its suitability for generating pseudorandom sequences. Based on the combined encryption and decryption times, CHIMA-64 requires 57.95–64.16% less time than PRESENT, while CHIMA-128 requires 23.60–59.36% less time than AES-128 and 13.32–47, as well as 10% less time than CLEFIA across the three platforms.
Open AccessCHIMA: Design and Evaluation of a Lightweight Cryptographic System for IoT Applications
Resource-constrained Internet of Things (IoT) devices motivate the investigation into cryptographic designs with measurable implementation costs. This work presents CHIMA (Cryptography cHaotic lIghtweight systeM and Authentication), an experimental system combining a key generator based on chaotic states, a Feistel cipher using the AES substitution box and a keyed bit permutation, and a Lesamnta-LW-based ciphertext check. Logistic, H’enon, and Lorenz systems are examined for key generation, and cipher variants with 64-bit and 128-bit blocks are evaluated. The study reports functional tests, avalanche measurements, NIST statistical tests, and implementation measurements on Arm Cortex-M0+, Cortex-M33, and Cortex-M7 microcontrollers. Controlled WiFi/MQTT and LoRa experiments assess communication interoperability. The results show that the chaotic key generator achieved high entropy and passed all NIST statistical tests, indicating its suitability for generating pseudorandom sequences. Based on the combined encryption and decryption times, CHIMA-64 requires 57.95–64.16% less time than PRESENT, while CHIMA-128 requires 23.60–59.36% less time than AES-128 and 13.32–47, as well as 10% less time than CLEFIA across the three platforms.
- Open Access
Comparison of Dimensional Accuracy between a Laser Scanner and a Laser Tracker with Handheld Scan in a Laboratory Setting
The dimensional accuracy of a laser scanner has been extensively evaluated using various measurement methods and diverse reference standards. This study specifically focuses on two key considerations. Firstly, it assesses the dimensional accuracy of the laser scanner by employing another laser scanner, a handheld scanner, as the reference measurement method. Secondly, the study involves the use of three spheres fixed on each wall in both coplanar and non-coplanar positions within a laboratory room at SENAI ISI-SIM. The primary objective is to determine the dimensional accuracy between the centers of the coplanar and non-coplanar spheres up to 10 m. The comparison includes measurement uncertainties, as per ISO GUM standards, obtained using the laser scanner in a laboratory setting with controlled temperature and humidity. Analyzing non-coplanar dimensional accuracy enhances our understanding of the metrological performance of the laser scanner, particularly when assessing the dimensions of objects positioned randomly within a scanning scene.
Open AccessComparison of Dimensional Accuracy between a Laser Scanner and a Laser Tracker with Handheld Scan in a Laboratory Setting
The dimensional accuracy of a laser scanner has been extensively evaluated using various measurement methods and diverse reference standards. This study specifically focuses on two key considerations. Firstly, it assesses the dimensional accuracy of the laser scanner by employing another laser scanner, a handheld scanner, as the reference measurement method. Secondly, the study involves the use of three spheres fixed on each wall in both coplanar and non-coplanar positions within a laboratory room at SENAI ISI-SIM. The primary objective is to determine the dimensional accuracy between the centers of the coplanar and non-coplanar spheres up to 10 m. The comparison includes measurement uncertainties, as per ISO GUM standards, obtained using the laser scanner in a laboratory setting with controlled temperature and humidity. Analyzing non-coplanar dimensional accuracy enhances our understanding of the metrological performance of the laser scanner, particularly when assessing the dimensions of objects positioned randomly within a scanning scene.
- Open Access
Estimation of Measurement Uncertainty of the Real-Time Location System (RTLS) with Ultra-Wideband (UWB) Technology
The need to control the real-time location of assets is increasingly relevant worldwide. The Ultra-wideband (UWB) technology is an IoT solution for real-time locating systems (RTLS). The location of the asset is obtained by the signal exchange between a wireless tag (asset) and fixed anchors. The tag interacts with the fixed anchors, defining its position through the distances obtained by trilateration. This data is sent to the server through the gateway. It is well-known that this process has several sources of errors. However, the measurement uncertainty assessment of UWB technology is an important topic regarding its scope of use. This paper presents a task-specific measurement uncertainty evaluation for the UWB positioning system, according to the ISO GUM. It aims to propose a method to support decision-making regarding the possible uses of UWB technology. The position provided by the UWB is compared with reference points using Cartesian coordinates that are measured with a total station, providing metrological reliability. Using the information from the estimated uncertainty, one can define the minimum tolerance interval associated with UWB technology for a given use. A case study demonstrates the method.
Open AccessEstimation of Measurement Uncertainty of the Real-Time Location System (RTLS) with Ultra-Wideband (UWB) Technology
The need to control the real-time location of assets is increasingly relevant worldwide. The Ultra-wideband (UWB) technology is an IoT solution for real-time locating systems (RTLS). The location of the asset is obtained by the signal exchange between a wireless tag (asset) and fixed anchors. The tag interacts with the fixed anchors, defining its position through the distances obtained by trilateration. This data is sent to the server through the gateway. It is well-known that this process has several sources of errors. However, the measurement uncertainty assessment of UWB technology is an important topic regarding its scope of use. This paper presents a task-specific measurement uncertainty evaluation for the UWB positioning system, according to the ISO GUM. It aims to propose a method to support decision-making regarding the possible uses of UWB technology. The position provided by the UWB is compared with reference points using Cartesian coordinates that are measured with a total station, providing metrological reliability. Using the information from the estimated uncertainty, one can define the minimum tolerance interval associated with UWB technology for a given use. A case study demonstrates the method.