    Repeatability and Reproducibility of an Automated Image-Processing Software for Quantitative Conjunctival Hyperemia Analysis: A Pilot Study

    by Linda Hansapinyo, Kessara Pathanapitoon, Napaporn Tananuvat, Winai Chaidaroon, Somsanguan Ausayakhun, Pichaya Kulniwatcharoen, Nathaya Panyowatkul, Timothy E. O’BRien, Karn Patanukhom

    OBJECTIVE Conjunctival hyperemia reflects the severity of various ocular conditions and is a common side effect of glaucoma medications, posing a significant concern for affected patients. Most existing clinical grading systems are subjective and rely heavily on individual physician interpretation, making interobserver comparison difficult. We developed an automated grading software to objectively and quantitatively assess conjunctival hyperemia. This study aimed to evaluate the repeatability and reproducibility of a newly developed automated software for quantitative assessment of conjunctival hyperemia in glaucoma patients in a pilot validation study. METHODS In this pilot study, glaucoma patients using at least one topical anti-glaucoma medication and exhibiting conjunctival hyperemia were enrolled. Each patient’s conjunctival hyperemia was assessed using the automated software, which segmented images into four regions: blood vessel area, strong red area, weak red area, and non-red area. An automatic region of interest (ROI) registration function was incorporated to enhance measurement consistency. Repeatability was assessed using two measurements from the same image, and reproducibility was tested using separate images of the same eye. RESULTS Eighty images from twenty glaucoma patients were analyzed (collected between December 1, 2016, and December 31, 2018). Following administration of 10% phenylephrine ophthalmic solution, the percentage of conjunctival hyperemia decreased significantly in all regions (p < 0.001). Spearman correlation coefficients for repeated measurements on the same image were 0.884 (blood vessel), 0.982 (strong red), and 0.932 (weak red). Corresponding values for repeated images of the same eye were 0.988, 0.992, and 0.995, respectively. The intraclass correlation coefficient (ICC) for clinical grading by ten ophthalmologists was 0.969 (95% CI: 0.952–0.981). CONCLUSION This pilot study demonstrates that the proposed automated software provides an objective and quantitative assessment of conjunctival hyperemia with excellent repeatability and reproducibility. The system shows high correlation with clinical grading and may serve as a reliable tool for monitoring conjunctival hyperemia changes in clinical practice.


  • Open Access

    Repeatability and Reproducibility of Automated Quantitative Conjunctival Hyperemia Analysis Software (Preprint)

    by Linda Hansapinyo, Kessara Pathanapitoon, Napaporn Tananuvat, Winai Chaidaroon, Somsanguan Ausayakhun, Pichaya Kulniwatcharoen, Nathaya Panyowatkul, Timothy E O’brien, Karn Patanukhom

    BACKGROUND The degree of conjunctival hyperemia reflects the severity of various ocular disease. Most of clinical grading systems rely on individual physicians and it is difficult to compare between clinical examinations. We developed automated grading software to objectively assess conjunctival hyperemia. OBJECTIVE To assess the repeatability and reproducibility of newly developed automated quantitative conjunctival hyperemia analysis software. METHODS Eighty images of twenty glaucoma patients who were using at least one anti-glaucoma medication and complained of conjunctival hyperemia were collected. All patients’ severity of conjunctival hyperemia was evaluated by newly developed automated conjunctival hyperemia grading software into 4 levels: blood vessel, strong red area, weak red area and non-red area. Automatic registration was applied for improving the software repeatability and reproducibility. RESULTS Spearman correlation coefficient values(rs) values of 0.884, 0.982 and 0.932 for blood vessel area, strong red area and weak red area of two measurements of the same image, respectively. Spearman correlation coefficient (rs) values of 0.988, 0.992 and 0.995 for blood vessel area, strong red area and weak red area of two images of the same eye, respectively. The clinical grading had the best correlation with the summation of blood vessel and strong red area, following with strong red area. CONCLUSIONS The proposed conjunctival hyperemia analysis software provides an automatically quantitative objective assessment of conjunctival hyperemia with excellent repeatability and reproducibility including excellent correlation with clinical grading by ophthalmologists. This algorithm including the automatic region of interest (ROI) registration between two images system give precise results in comparing the conjunctival hyperemic change in clinical practice.