LPLuke Phillips

Luke Phillips

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luke Phillips has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimising POCUS programs: A summary of EMUG's recommendations for the development and maintenance of ED POCUS programs

    by Luke Phillips, Alastair Maclean, Josh Monester, Joanne Douglas, Stacey Davidson, Gabriela King

    Objectives: Point‐of‐care ultrasound (POCUS) use is widespread in EDs and throughout those practising medicine. Between institutions and specialities, there is widespread variety and training. With this comes risk of patient harm and backlash to a clinically useful modality. Our objective is to form a statement that encompasses current published and unpublished guidance for creating and maintaining robust POCUS programs in EDs.Methods: Emergency Medicine Ultrasound Group (EMUG) identified this gap and volunteers from the group undertook a literature search of current best practice and institution guidelines relating to POCUS programs. They contacted colleagues from other specialities to find and get access to other countries and colleges' POCUS guidelines. EMUGs regularly run discussion forums (Collab‐labs) and points from these were considered. Recommendations were then formed from these and recurrent unpublished obstacles the group had encountered. The result was reviewed by Clinical Leads in Ultrasound and POCUS users in Australasia.Results: The recommendations were organised under five pillars: Infrastructure, Governance, Administration, Education and Quality.Conclusion: These recommendations complement existing guidelines and are not intended to replace them; however, we hope to promote discussion and provide reference support for those developing POCUS programs. Implementing a comprehensive and robust ED POCUS program will ensure safe, effective, and standardised high‐quality POCUS use, with the aim of improving patient care across Australia and New Zealand. Patient safety will be enhanced through effective risk management and quality assurance and there will be consistency in POCUS education, training and credentialing across institutions.

  • Open Access

    Recommendations for developing a comprehensive point‐of‐care ultrasound (POCUS) program in the emergency department: an Emergency Medicine Ultrasound Group advocacy statement

    by Luke Phillips, Alastair Maclean, Josh Monester, Joanne Douglas, Stacey Davidson, Gabriela King

    Objectives: Point‐of‐care ultrasound (POCUS) use is widespread in EDs and throughout those practising medicine. Between institutions and specialities, there is widespread variety and training. With this comes the risk of patient harm and backlash to a clinically useful modality. Our objective is to form a statement that encompasses current published and unpublished guidance for creating and maintaining robust POCUS programs in EDs.Methods: Emergency Medicine Ultrasound Group (EMUG) identified this gap and volunteers from the group undertook a literature search of current best practice and institution guidelines relating to POCUS programs. They contacted colleagues from other specialities to find and get access to other countries and colleges' POCUS guidelines. EMUGs regularly run discussion forums (Collab‐labs) and points from these were considered. Recommendations were then formed from these and recurrent unpublished obstacles the group had encountered. The result was reviewed by clinical leaders in ultrasound and POCUS users in Australasia.Results: The recommendations were organised under five pillars: Infrastructure, Governance, Administration, Education and Quality.Conclusion: These recommendations complement existing guidelines and are not intended to replace them; however, we hope to promote discussion and provide reference support for those developing POCUS programs. Implementing a comprehensive and robust ED POCUS program will ensure safe, effective and standardised high‐quality POCUS use, with the aim of improving patient care across Australia and New Zealand. Patient safety will be enhanced through effective risk management and quality assurance and there will be consistency in POCUS education, training and credentialing across institutions.


  • Open Access

    Comparison of lung ultrasound scoring systems for the prognosis of COVID‐19 in the emergency department: An international prospective cohort study

    by Peter J Snelling, Philip Jones, Rory Connolly, Tomislav Jelic, Dan Mirsch, Frank Myslik, Luke Phillips, Gabriel Blecher, the COVID LUS Study Group

    Purpose: The purpose of this study was to evaluate whether the lung ultrasound (LUS) scores applied to an international cohort of patients presenting to the emergency department (ED) with suspected COVID‐19, and subsequently admitted with proven disease, could prognosticate clinical outcomes.Methods: This was an international, multicentre, prospective, observational cohort study of patients who received LUS and were followed for the composite primary outcome of intubation, intensive care unit (ICU) admission or death. LUS scores were later applied including two 12‐zone protocols (‘de Alencar score’ and ‘CLUE score’), a 12‐zone protocol with lung and pleural findings (‘Ji score’) and an 11‐zone protocol (‘Tung‐Chen score’). The primary analysis comprised logistic regression modelling of the composite primary outcome, with the LUS scores analysed individually as predictor variables.Results: Between April 2020 to April 2022, 129 patients with COVID‐19 had LUS performed according to the protocol and 24 (18.6%) met the composite primary endpoint. No association was seen between the LUS score and the composite primary end point for the de Alencar score [odds ratio (OR) = 1.04; 95% confidence interval (CI): 0.97–1.11; P = 0.29], the CLUE score (OR = 1.03; 95% CI: 0.96–1.10; P = 0.40), the Ji score (OR = 1.02; 95% CI: 0.97–1.07; P = 0.40) or the Tung‐Chen score (OR = 1.02; 95% CI: 0.97–1.08).Discussion: Compared to these earlier studies performed at the start of the pandemic, the negative outcome of our study could reflect the changing scenario of the COVID‐19 pandemic, including patient, disease, and system factors. The analysis suggests that the study may have been underpowered to detect a weaker association between a LUS score and the primary outcome.Conclusion: In an international cohort of adult patients presenting to the ED with suspected COVID‐19 disease who had LUS performed and were subsequently admitted to hospital, LUS severity scores did not prognosticate the need for invasive ventilation, ICU admission or death.

  • Use of Point-of-Care Ultrasound by Intensive Care Paramedics to Assess Respiratory Distress in the Out-of-Hospital Environment: A Pilot Study

    by Jake K. Donovan, Samuel O. Burton, Samuel L. Jones, Luke M. Phillips, David Anderson, Benjamin N. Meadley

    Background Respiratory distress is a common presentation attended by paramedics. Chest auscultation has been shown to have low accuracy for diagnosing respiratory complaints, and this can lead to inaccurate patient assessment and potentially poor patient outcomes. Conversely, lung ultrasound is a relatively simple exam allowing for rapid differentiation of respiratory complaints with comparable accuracy to more advanced imaging modalities. Evidence suggests that lung ultrasound is easy to learn and apply and could be ideal for assessment of respiratory illness by paramedics. Objective This study aimed to explore the utility of out-of-hospital lung ultrasound performed by intensive care paramedics (ICP) for patients with medical causes of respiratory distress, and explore whether the use of lung ultrasound affects the ICP’s clinical impression or management. Methods This was a prospective observational pilot study. After a training program, a sample of ICPs working in metropolitan and regional Victoria, Australia used ultrasound to assess adult patients with respiratory distress and/or dyspnea. ICPs used a handheld point-of-care ultrasound device to scan respiratory patients using a modified protocol, and completed a worksheet with their scan findings. The scans were then reviewed by a subject matter expert for quality and agreement. Results Ninety-five patients were enrolled over the study period. The average image quality score was 2.68/5, and 56% of scans were of interpretable quality. Interrater agreement (between the ICPs and the subject matter expert) was reported using Cohen’s kappa. Moderate overall agreement (0.44) was shown, with the highest reliability reported in A-profile and B-profile (0.49 and 0.57). In 42% of cases performance of the scan affected paramedic clinical impression and/or management. Conclusion ICPs can perform lung ultrasound with moderate accuracy for some respiratory conditions, and the scans may affect clinical impression and management. Future research should focus on enhanced education, expert feedback, and clinical outcomes.