Rui He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rui He has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Changsheng Li
School of Mechatronical Engineering Beijing Institute of Technology Beijing China
7 shared publications - Xingguang Duan
School of Medical Engineering, Beijing Institute of Technology, Zhuhai, China
6 shared publications - Qingxin Shi
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Tengfei Cui
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Fansheng Meng
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100089, China
1 shared publication Hao Wen
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China
1 shared publication
Latest Publications
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 492-501
Development and Validation of a Robot-Assisted Retraction System for Orthopedic Surgery
Tissue retraction, one of the basic steps in orthopedic surgery, is related to the smooth entry of surgical instruments into the surgical area and provides a clear surgical perspective for surgeons. This work introduces the first robot-assisted retraction system (RARS) specifically designed for orthopedic surgery. The RARS allows surgeons to set a safe retraction force and roughly set the posture of the retraction device at the beginning. To ensure that the RARS automatically completes the task in a safe manner, we propose a safety control framework that employs iterative enhanced control based on interaction model to handle the retraction interaction problem, and avoids interference with the operation of surgeons through null-space optimization. First, we performed a performance test of the RARS on a phantom model, and the results showed that the maximum tracking error of the retraction force was 0.51N, demonstrating satisfactory tracking performance. Second, we validated the effectiveness of null-space optimization by observing the evolution of joint positions. Finally, we conducted experiments on in-vivo animal and the results showed that the proposed RARS exhibited superior performance in safe retraction force tracking accuracy and tissue damage compared to traditional manual retractions.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 492-501
Development and Validation of a Robot-Assisted Retraction System for Orthopedic Surgery
Tissue retraction, one of the basic steps in orthopedic surgery, is related to the smooth entry of surgical instruments into the surgical area and provides a clear surgical perspective for surgeons. This work introduces the first robot-assisted retraction system (RARS) specifically designed for orthopedic surgery. The RARS allows surgeons to set a safe retraction force and roughly set the posture of the retraction device at the beginning. To ensure that the RARS automatically completes the task in a safe manner, we propose a safety control framework that employs iterative enhanced control based on interaction model to handle the retraction interaction problem, and avoids interference with the operation of surgeons through null-space optimization. First, we performed a performance test of the RARS on a phantom model, and the results showed that the maximum tracking error of the retraction force was 0.51N, demonstrating satisfactory tracking performance. Second, we validated the effectiveness of null-space optimization by observing the evolution of joint positions. Finally, we conducted experiments on in-vivo animal and the results showed that the proposed RARS exhibited superior performance in safe retraction force tracking accuracy and tissue damage compared to traditional manual retractions.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
Unified Admittance Control for Accurate Puncture and Respiration Following Based on Disturbance Observation and Model Predictive Control
Percutaneous puncture is the clinical standard for diagnosis and therapy of lung tumors. Needle placement accuracy and safety are of great significance but severely affected by respiration. In this letter, a unified admittance control method for accurate puncture and respiration following is proposed. For lung puncture robots, an admittance puncture model considering remote center of motion (RCM) constraint, respiration and needle bending is first proposed, in which angular velocity feedforward is used to decrease the tearing force. Then, under real-time images, extended state observer (ESO) is introduced to observe needle bending and respiration motion velocity relative to the robot, which are further compensated. The resulting integral system is used to designed dynamic response for accurate puncture. Finally, robot output force is optimized with model predictive control (MPC) and designed in a unified form to be compliant with the needle force for respiration following and overcome it for accurate puncture. Experiment results show accurate puncture under static condition with small steady-state error, designed dynamic response and small tearing force, and respiration following with small interaction force and nearly constant needle angle and position relative to lung, which indicate high clinical value for robotic lung puncture.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
Unified Admittance Control for Accurate Puncture and Respiration Following Based on Disturbance Observation and Model Predictive Control
Percutaneous puncture is the clinical standard for diagnosis and therapy of lung tumors. Needle placement accuracy and safety are of great significance but severely affected by respiration. In this letter, a unified admittance control method for accurate puncture and respiration following is proposed. For lung puncture robots, an admittance puncture model considering remote center of motion (RCM) constraint, respiration and needle bending is first proposed, in which angular velocity feedforward is used to decrease the tearing force. Then, under real-time images, extended state observer (ESO) is introduced to observe needle bending and respiration motion velocity relative to the robot, which are further compensated. The resulting integral system is used to designed dynamic response for accurate puncture. Finally, robot output force is optimized with model predictive control (MPC) and designed in a unified form to be compliant with the needle force for respiration following and overcome it for accurate puncture. Experiment results show accurate puncture under static condition with small steady-state error, designed dynamic response and small tearing force, and respiration following with small interaction force and nearly constant needle angle and position relative to lung, which indicate high clinical value for robotic lung puncture.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 4592-4604
Output Finitely Constrained Control of Robotic Manipulators With Composite Desaturation Method
This article explores the challenges of input saturation and output constraints in the context of a dynamic tracking task for robotic manipulators, considering model uncertainties and the absence of velocity measurements. First, a time-varying global barrier Lyapunov function (GBLF) is designed without restrictions on its application to achieve finite output constraints. Subsequently, an adaptive boundary mode and a new auxiliary system are proposed as part of a composite desaturation scheme to address input saturation. The adaptive boundary mode adjusts GBLF-related control signals while the auxiliary system generates compensation signals for each order subsystem for desaturation. Then, an extended state observer and a radial basis function neural network are employed to estimate velocities and lumped uncertainties, respectively. Finally, a novel controller integrating the aforementioned techniques is derived, achieving satisfactory convergence for each processor of the controller. The advantages of this controller lie in its effective resolution of existing BLFs' applicability issues and noticeable improvement in desaturation rate. Experiments validate the effectiveness and superiority of the proposed method.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 4592-4604
Output Finitely Constrained Control of Robotic Manipulators With Composite Desaturation Method
This article explores the challenges of input saturation and output constraints in the context of a dynamic tracking task for robotic manipulators, considering model uncertainties and the absence of velocity measurements. First, a time-varying global barrier Lyapunov function (GBLF) is designed without restrictions on its application to achieve finite output constraints. Subsequently, an adaptive boundary mode and a new auxiliary system are proposed as part of a composite desaturation scheme to address input saturation. The adaptive boundary mode adjusts GBLF-related control signals while the auxiliary system generates compensation signals for each order subsystem for desaturation. Then, an extended state observer and a radial basis function neural network are employed to estimate velocities and lumped uncertainties, respectively. Finally, a novel controller integrating the aforementioned techniques is derived, achieving satisfactory convergence for each processor of the controller. The advantages of this controller lie in its effective resolution of existing BLFs' applicability issues and noticeable improvement in desaturation rate. Experiments validate the effectiveness and superiority of the proposed method.
- 25 December 2024
- Published by Springer Nature
- p. 21-28
Design and Baseline Drift Compensation for Respiratory Acquisition Devices
- 25 December 2024
- Published by Springer Nature
- p. 21-28
Design and Baseline Drift Compensation for Respiratory Acquisition Devices
- Open Access
Fixed-Time Recurrent NN Learning Control of Uncertain Robotic Manipulators with Time-Varying Constraints: Experimental Verification
This paper proposes a learning control framework for the robotic manipulator’s dynamic tracking task demanding fixed-time convergence and constrained output. In contrast with model-dependent methods, the proposed solution deals with unknown manipulator dynamics and external disturbances by virtue of a recurrent neural network (RNN)-based online approximator. First, a time-varying tangent-type barrier Lyapunov function (BLF) is introduced to construct a fixed-time virtual controller. Then, the RNN approximator is embedded in the closed-loop system to compensate for the lumped unknown term in the feedforward loop. Finally, we devise a novel fixed-time, output-constrained neural learning controller by integrating the BLF and RNN approximator into the main framework of the dynamic surface control (DSC). The proposed scheme not only guarantees the tracking errors converge to the small neighborhoods about the origin in a fixed time, but also preserves the actual trajectories always within the prescribed ranges and thus improves the tracking accuracy. Experiment results illustrate the excellent tracking performance and verify the effectiveness of the online RNN estimate for unknown dynamics and external disturbances.
Open AccessFixed-Time Recurrent NN Learning Control of Uncertain Robotic Manipulators with Time-Varying Constraints: Experimental Verification
This paper proposes a learning control framework for the robotic manipulator’s dynamic tracking task demanding fixed-time convergence and constrained output. In contrast with model-dependent methods, the proposed solution deals with unknown manipulator dynamics and external disturbances by virtue of a recurrent neural network (RNN)-based online approximator. First, a time-varying tangent-type barrier Lyapunov function (BLF) is introduced to construct a fixed-time virtual controller. Then, the RNN approximator is embedded in the closed-loop system to compensate for the lumped unknown term in the feedforward loop. Finally, we devise a novel fixed-time, output-constrained neural learning controller by integrating the BLF and RNN approximator into the main framework of the dynamic surface control (DSC). The proposed scheme not only guarantees the tracking errors converge to the small neighborhoods about the origin in a fixed time, but also preserves the actual trajectories always within the prescribed ranges and thus improves the tracking accuracy. Experiment results illustrate the excellent tracking performance and verify the effectiveness of the online RNN estimate for unknown dynamics and external disturbances.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 21 (2) , 1899-1910
Virtual-Fixtures Based Shared Control Method for Curve-Cutting With a Reciprocating Saw in Robot-Assisted Osteotomy
In mandibular angle split osteotomy (MASO), prominent mandibular angles need to be cut off with saws such as reciprocating saws. Compared to traditional-freehand methods, robot-assisted methods provide potentials for better cutting performance. In the robot-assisted mandibular angle split osteotomy (RAMASO), a cutting method based on shared control is proposed along with an optimization-planned osteotomy curve. Experimental verification using planes and skull phantoms were conducted and discussed for evaluation of accuracy and safety. The results in 7 cutting experiments for the following error were mainly within 0.76mm and -1.00mm (Q3 $\pm$ 1.5*IQR), peaking at 1.80 mm. The maximum of time-consuming was 304.0s, with the average human robot interactive force reaching around 3.3 N. Experiments indicate the proposed method achieves better performance in accuracy and efficiency compared with the free hand. Note to Practitioners —This paper is inspired by the curve-cutting osteotomy task under the combination of pre-defined virtual fixtures and the kinematic constraint of the reciprocating saw. The motions of current surgical osteotomy robots are mostly generated by either of virtual fixtures and kinematic constraints, which is representing less autonomy on surgery. The introduction of autonomy in surgical robotics can greatly increase the surgeon’s performance in efficiency, accuracy, and safety. The technique of shared control is capable of achieving the semi-autonomy task to significantly improve the accuracy with feedback mechanisms in control science. Thus, the advanced control strategies are required into the process of surgical osteotomy operation. In this article, we proposed a novel methodology to control the hands-on robot executing a curve path. The developed control scheme has the following functionalities: 1) it enables the lateral control for the cutting task for the hands-on robot system. 2) it maintains the pre-defined path-generated virtual fixtures and finds the optimal-parameters of the virtual fixtures. For the convenience of presentation, the mandibular angle split osteotomy is chosen as the background, but in fact this method can be extended to more surgical and even industrial applications with a similar scenario.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 21 (2) , 1899-1910
Virtual-Fixtures Based Shared Control Method for Curve-Cutting With a Reciprocating Saw in Robot-Assisted Osteotomy
In mandibular angle split osteotomy (MASO), prominent mandibular angles need to be cut off with saws such as reciprocating saws. Compared to traditional-freehand methods, robot-assisted methods provide potentials for better cutting performance. In the robot-assisted mandibular angle split osteotomy (RAMASO), a cutting method based on shared control is proposed along with an optimization-planned osteotomy curve. Experimental verification using planes and skull phantoms were conducted and discussed for evaluation of accuracy and safety. The results in 7 cutting experiments for the following error were mainly within 0.76mm and -1.00mm (Q3 $\pm$ 1.5*IQR), peaking at 1.80 mm. The maximum of time-consuming was 304.0s, with the average human robot interactive force reaching around 3.3 N. Experiments indicate the proposed method achieves better performance in accuracy and efficiency compared with the free hand. Note to Practitioners —This paper is inspired by the curve-cutting osteotomy task under the combination of pre-defined virtual fixtures and the kinematic constraint of the reciprocating saw. The motions of current surgical osteotomy robots are mostly generated by either of virtual fixtures and kinematic constraints, which is representing less autonomy on surgery. The introduction of autonomy in surgical robotics can greatly increase the surgeon’s performance in efficiency, accuracy, and safety. The technique of shared control is capable of achieving the semi-autonomy task to significantly improve the accuracy with feedback mechanisms in control science. Thus, the advanced control strategies are required into the process of surgical osteotomy operation. In this article, we proposed a novel methodology to control the hands-on robot executing a curve path. The developed control scheme has the following functionalities: 1) it enables the lateral control for the cutting task for the hands-on robot system. 2) it maintains the pre-defined path-generated virtual fixtures and finds the optimal-parameters of the virtual fixtures. For the convenience of presentation, the mandibular angle split osteotomy is chosen as the background, but in fact this method can be extended to more surgical and even industrial applications with a similar scenario.
- Open Access
Improving the Force Display of Haptic Device Based on Gravity Compensation for Surgical Robotics
Haptic devices are applied as masters to provide force displays for telemedicinal robots. Gravity compensation has been proven to be crucial for the accuracy and capability of force displays, which are critical for haptic devices to assist operators. Therefore, the existing method suffers from an unsatisfactory effect, a complex implementation, and low efficiency. In this paper, an approach combining active and passive gravity compensation is proposed to improve the performance of a force display. The passive compensation is conducted by counterweights fixed with the moving platform and pantographs to offset most of the gravity and reduce the loads of the motors, while the peak capability of the force display is enhanced. The required weight is optimized by a multi-objective genetic algorithm in terms of the maximum torque of the motors in the global workspace. As a supplement, the residual gravity is eliminated by active compensation to extend the accuracy of the force display. The balancing forces in the discretized workspace are entirely calibrated, and the required force for the arbitrary configuration is calculated by interpolations. The decisions regarding the algorithm parameters are also discussed to achieve a compromise between the effect and elapsed time. Finally, the prototype with a compensation mechanism is implemented and experiments are carried out to verify the performance of the proposed method. The results show that the peak capability of the force display is enhanced by 45.43% and the maximum deviation is lowered to 0.6 N.
Open AccessImproving the Force Display of Haptic Device Based on Gravity Compensation for Surgical Robotics
Haptic devices are applied as masters to provide force displays for telemedicinal robots. Gravity compensation has been proven to be crucial for the accuracy and capability of force displays, which are critical for haptic devices to assist operators. Therefore, the existing method suffers from an unsatisfactory effect, a complex implementation, and low efficiency. In this paper, an approach combining active and passive gravity compensation is proposed to improve the performance of a force display. The passive compensation is conducted by counterweights fixed with the moving platform and pantographs to offset most of the gravity and reduce the loads of the motors, while the peak capability of the force display is enhanced. The required weight is optimized by a multi-objective genetic algorithm in terms of the maximum torque of the motors in the global workspace. As a supplement, the residual gravity is eliminated by active compensation to extend the accuracy of the force display. The balancing forces in the discretized workspace are entirely calibrated, and the required force for the arbitrary configuration is calculated by interpolations. The decisions regarding the algorithm parameters are also discussed to achieve a compromise between the effect and elapsed time. Finally, the prototype with a compensation mechanism is implemented and experiments are carried out to verify the performance of the proposed method. The results show that the peak capability of the force display is enhanced by 45.43% and the maximum deviation is lowered to 0.6 N.