Camilla Giaccaglia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Camilla Giaccaglia has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Flacco
Laboratoire d'Optique Appliquée, ENSTA Paris, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France
4 shared publications Amar Tafzi
Laboratoire d'Optique Appliquée (LOA), CNRS, Ecole polytechnique, ENSTA, Institut Polytechnique de Paris, Palaiseau, France
3 shared publications- Charles Fouillade
Institut Curie, Inserm U1021-CNRS UMR 3347, University Paris-Saclay, PSL Research University, Centre Universitaire, 91405 Orsay Cedex, France
3 shared publications Isabelle Lamarre-Jouenne
Laboratoire d'Optique et Biosciences, CNRS, Inserm, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France
3 shared publicationsJean-Philippe Goddet
Laboratoire d'Optique Appliquée (LOA), CNRS, Ecole polytechnique, ENSTA, Institut Polytechnique de Paris, Palaiseau, France
3 shared publications- Julien Gautier
Laboratoire d’Optique Appliquée
3 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (6) , 102028
Multiscale Radiobiological Assessment of Laser-Driven Very High Energy Electrons Versus Conventional Electrons
- 27 March 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (6) , 102028
Open AccessMultiscale Radiobiological Assessment of Laser-Driven Very High Energy Electrons Versus Conventional Electrons
- Open Access
Laser-driven VHEE pulsed fast fractionation (PFF): second-scale inter-pulse timing differentially modulates normal tissue and tumour toxicity
Radiotherapy (RT) is constrained by the narrow therapeutic window between tumour control and normal-tissue toxicity. While FLASH RT has been reported to reduce normal-tissue toxicity at ultra-high dose rates (UHDR) with preserved tumour control in several preclinical models, the radiobiological potential of temporal regimes intermediate between conventional fractionation and FLASH remains largely unexplored. Here, we use a laser-plasma accelerator (LPA) to access this regime by delivering sub-picosecond very high-energy electron (VHEE, 50–300 MeV) pulses at ultra-high instantaneous dose rates (UHIDR; > 10^9 Gy/s) with externally programmable inter-pulse intervals. We introduce Pulsed Fast Fractionation (PFF): ultrashort (fs-ps) pulses delivered under UHIDR conditions with second-scale inter-pulse intervals and implementation-dependent dose per pulse. In this work, we vary the inter-pulse interval from 1 to 10 s while keeping dose per pulse and total dose constant, and identify an interval of 1 s that enhances normal-tumour separation: human fibroblasts exhibit reduced toxicity, whereas colorectal carcinoma cells show increased cytotoxicity under matched dose conditions. In vivo, zebrafish embryos reproduce the interval-dependent normal-tissue protection, supporting relevance in a whole-organism context. These results establish second-scale pulse timing as a biologically active degree of freedom for VHEE delivery, positioning PFF as a temporally optimised approach that complements spatial dose modulation and extends the current fractionation-FLASH framework.
Open AccessLaser-driven VHEE pulsed fast fractionation (PFF): second-scale inter-pulse timing differentially modulates normal tissue and tumour toxicity
Radiotherapy (RT) is constrained by the narrow therapeutic window between tumour control and normal-tissue toxicity. While FLASH RT has been reported to reduce normal-tissue toxicity at ultra-high dose rates (UHDR) with preserved tumour control in several preclinical models, the radiobiological potential of temporal regimes intermediate between conventional fractionation and FLASH remains largely unexplored. Here, we use a laser-plasma accelerator (LPA) to access this regime by delivering sub-picosecond very high-energy electron (VHEE, 50–300 MeV) pulses at ultra-high instantaneous dose rates (UHIDR; > 10^9 Gy/s) with externally programmable inter-pulse intervals. We introduce Pulsed Fast Fractionation (PFF): ultrashort (fs-ps) pulses delivered under UHIDR conditions with second-scale inter-pulse intervals and implementation-dependent dose per pulse. In this work, we vary the inter-pulse interval from 1 to 10 s while keeping dose per pulse and total dose constant, and identify an interval of 1 s that enhances normal-tumour separation: human fibroblasts exhibit reduced toxicity, whereas colorectal carcinoma cells show increased cytotoxicity under matched dose conditions. In vivo, zebrafish embryos reproduce the interval-dependent normal-tissue protection, supporting relevance in a whole-organism context. These results establish second-scale pulse timing as a biologically active degree of freedom for VHEE delivery, positioning PFF as a temporally optimised approach that complements spatial dose modulation and extends the current fractionation-FLASH framework.
- Open Access
Multiscale radiobiological assessment of laser-driven very high energy electrons versus conventional electrons
Purpose: This study systematically investigates the radiobiological effects of Very High Energy Electrons (VHEE) generated by a laser-plasma accelerator (LPA), in comparison with Conventional Intermediate Energy Electrons (CIEE) from a conventional linear accelerator (LINAC). Using in vitro, ex vivo , and in vivo models, we evaluate and compare their potential toxicity on healthy tissues. Methods and Materials: Cell survival, tissue response, and developmental toxicity were assessed across three biological models. In vitro , human fibroblasts (MRC5-hTERT) were used to generate post-irradiation survival curves. Ex vivo , precision-cut lung slices (PCLS) from mice were analyzed for radiation-induced inhibition of cell proliferation. In vivo , zebrafish embryos were used to evaluate developmental toxicity through body length and spinal curvature measurements. VHEE irradiations were performed using a broadband electron beam spanning 50–300 MeV, using the Salle Jaune LPA (Laboratoire d’Optique Appliquée, France), while CIEE exposures were performed with a 7 MeV conventional LINAC (Institut Curie, France). Results: In vitro , MRC5-hTERT cells showed no significant difference in radiosensitivity between VHEE and CIEE, with comparable D 10 values (p-value = 0.7). In the ex vivo model, both beams induced a dose-dependent decrease in cell division with no significant inter-beam differences at any dose level (p-value > 0.99). In vivo , zebrafish embryos exhibited dose-dependent body shortening and increased spinal curvature following both VHEE and CIEE exposure. No significant differences were observed between the two modalities at matched doses for any measured metric (p-value ≥ 0.5). Conclusion: This study presents the first comprehensive radiobiological evaluation of a laser-driven VHEE beam across multiple biological models. Under the investigated conditions, VHEE and CIEE irradiations exhibit similar biological toxicity. These findings support the feasibility and potential of VHEE generated with LPA for future clinical applications.
Open AccessMultiscale radiobiological assessment of laser-driven very high energy electrons versus conventional electrons
Purpose: This study systematically investigates the radiobiological effects of Very High Energy Electrons (VHEE) generated by a laser-plasma accelerator (LPA), in comparison with Conventional Intermediate Energy Electrons (CIEE) from a conventional linear accelerator (LINAC). Using in vitro, ex vivo , and in vivo models, we evaluate and compare their potential toxicity on healthy tissues. Methods and Materials: Cell survival, tissue response, and developmental toxicity were assessed across three biological models. In vitro , human fibroblasts (MRC5-hTERT) were used to generate post-irradiation survival curves. Ex vivo , precision-cut lung slices (PCLS) from mice were analyzed for radiation-induced inhibition of cell proliferation. In vivo , zebrafish embryos were used to evaluate developmental toxicity through body length and spinal curvature measurements. VHEE irradiations were performed using a broadband electron beam spanning 50–300 MeV, using the Salle Jaune LPA (Laboratoire d’Optique Appliquée, France), while CIEE exposures were performed with a 7 MeV conventional LINAC (Institut Curie, France). Results: In vitro , MRC5-hTERT cells showed no significant difference in radiosensitivity between VHEE and CIEE, with comparable D 10 values (p-value = 0.7). In the ex vivo model, both beams induced a dose-dependent decrease in cell division with no significant inter-beam differences at any dose level (p-value > 0.99). In vivo , zebrafish embryos exhibited dose-dependent body shortening and increased spinal curvature following both VHEE and CIEE exposure. No significant differences were observed between the two modalities at matched doses for any measured metric (p-value ≥ 0.5). Conclusion: This study presents the first comprehensive radiobiological evaluation of a laser-driven VHEE beam across multiple biological models. Under the investigated conditions, VHEE and CIEE irradiations exhibit similar biological toxicity. These findings support the feasibility and potential of VHEE generated with LPA for future clinical applications.
- 17 March 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (3)
Physics of high-charge laser-plasma accelerators for few-MeV applications
- 17 March 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (3)
Physics of high-charge laser-plasma accelerators for few-MeV applications
- 27 March 2023
- Published by Elsevier in Physica Medica
- Vol. 108, 102571
Characterization of a CdTe single-photon-counting detector for biomedical imaging applications
- 27 March 2023
- Published by Elsevier in Physica Medica
- Vol. 108, 102571
Characterization of a CdTe single-photon-counting detector for biomedical imaging applications