Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Angel Pena-Quintal has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    On Accelerated Degradation of DC-Link Film Capacitors and Data-Based Lifetime Estimation

    by Angel Pena-Quintal, Uvais Mustafa, Chris Gerada, Rishad Ahmed

    Methods to address the lifetime of film capacitors are a new trend, which have come about due to the importance of control algorithms relying on the stability and the reliability of this passive device for controlling ever-increasing power with optimal power conversion efficiency in modern powertrains of electrical vehicles. Capacitance degradation over time is a key-parameter to determine the lifetime of an electric vehicle drive and to provide safety to the passengers. In this paper, a method to account for the degradation of film capacitors is presented considering a charge-and-discharge method at a steady temperature to better understand its capacitance and equivalent series resistor changing behaviour. The temperature of the capacitor is set at a maximum rated level (from the manufacturer information) to assess an accelerated degradation, to address the physics of failure for these film capacitors and to propose a lifetime estimation method for them.


  • Open Access

    The Effect of Spread Spectrum Modulation on Power Line Communications

    by Seda Ustun Ercan, Angel Pena-Quintal, Dave Thomas

    Interference in Power Line Communication (PLC) is examined in this paper. PLC is a wired communication technology that provides communication and data transmission over the existing electrical network. It uses the electrical wiring in buildings or the electrical grid to transmit data signals between devices, rather than using dedicated communication cables or wireless signals. Many applications employ PLC technologies, which have the benefit of leveraging existing power connections for both power and data transfer, reducing cost and complexity. These interactions may be observed in contemporary smart grids and automobile power networks, where lengthy cables, switching power supplies and communication links all work together but exacerbate Electromagnetic Interference (EMI) problems. This research examines the effects of spread spectrum methods used to reduce EMI from power converters on PLC systems. Spread Spectrum Modulation (SSM) and its three variants, Sine, Random and Sawtooth, are frequently employed to meet the requirements of electromagnetic compatibility, however, there are some repercussions that may be detrimental to the converter or the rest of the electrical network. These outcomes occur for various modulation algorithm settings and at various frequencies. Measurements are made utilising the Frame Error Rate (FER) value provided by the PLC link system to ascertain the interference produced by a Silicon Carbide (SiC)-based DC-DC converter in order to investigate these concerns and standardise an assessment approach. To examine the effect of SSM on reducing EMI in the frequency domain, the peak index of a CISPR-16 EMI receiver is used.


  • Open Access

    The Effect of Spread Spectrum Modulation on Power Line Communications

    by Seda Ustun Ercan, Angel Pena-Quintal, Dave Thomas

    Interference on Power Line Communication (PLC), which is a wired communication technology that provides communication and data transmission over the existing electrical network, is examined in this paper. Many applications employ PLC technologies, which have the benefit of leveraging existing power connections for both power and data transfer, reducing cost and complexity. These interactions may be observed in contemporary smart grids and automobile power networks, where lengthy cables, switching power supplies, and communication links all work together but exacerbate electromagnetic interference problems. This research examines the effects of Spread Spectrum methods used to reduce EMI from power converters on PLC systems. Spread spectrum modulation and its three variants Sine, Random and Triangle are frequently employed to meet the requirements of electromagnetic compatibility, however there are some repercussions, that might be detrimental to the converter or the rest of the electrical network. These outcomes occur for various modulation algorithm settings and at various frequencies. Measurements are made utilising the Frame Error Rate value provided by the PLC link system to ascertain the interference produced by a SiC-based DC-DC converter in order to investigate these concerns and standardise an assessment approach.


  • On Spread Spectrum for DC Grids: Low-Frequency Conducted EMI Mitigation and Signal Integrity Disruption in Serial Communication Links

    by Angel Pena-Quintal, Waseem El Sayed, Mark Sumner, Seda Ustun Ercan, Steve Greedy, Dave Thomas, Robert Smolenski

    This article addresses the effects on nearby communication systems when spread spectrum modulation techniques are used for a dc–dc power converter. These interactions can be found in modern smart grids and automotive power networks in which the combination of communication links, switching power supplies, and long cables play a major role in electromagnetic interference issues at low frequencies below 150 kHz. Spread spectrum modulation, with its different variations (sine and random) are widely used to comply with electromagnetic compatibility standards. However, there are certain effects that can be harmful to either the converter or the rest of the power network. These effects happen at different frequencies and for different parameters used in the modulation algorithm. With the aim to standardize an assessment procedure, measurements are made to determine the interference created by an SiC-based dc–dc converter. The peak index of a CISPR-16 EMI receiver is used to evaluate the behavior in the frequency domain while a study in serial communication disruption is undertaken using mean and quantile values from a bit error rate tester.


  • Open Access

    The “Smart” Concept from an Electrical Sustainability Viewpoint

    by Ignacio Llanez-Caballero, Luis Ibarra, Angel Peña-Quintal, Glendy Catzín-Contreras, Pedro Ponce, Arturo Molina, Ricardo Ramirez-Mendoza

    Nowadays, there are many technological-intensive applications that claim to be “smart”. From smartphones to the smart grid, people relate the word smart with technical novelty, automation, enabled communication, and service integration. There is indeed a gap between those smart technologies and their intended “intelligence”; this has arisen an indirect debate between works focusing on automation and mechatronics design and others pursuing a conceptual approach based on fulfilling determinate objectives. One last approach relates the said smartness to deep learning methodologies. In this work, it is attempted to explore both perspectives by providing an overview of recent works around energy usage toward smart cities and the smart grid, pointing out the main conceptual pillars upon which both approaches stand. Certainly, there are enabling technologies supporting the smart concept overall; thus, this work addresses them to characterize “smart” not from technological or conceptual one-sided viewpoints but from their common backbone. Therefore, the interested reader can find in this work an integrative conceptualization of the smart context, a literature review of recent advances, and a deep discussion of how enabling technologies and current technological trends based on energy consumption are shaping the ongoing efforts toward a sustainable future. More importantly, a new approach to define smart in the said context is elaborated far from the typical misunderstanding of technological nesting or mere usage of “advanced” digital technologies. Rather, smartness is addressed by the integrative objectives the application pursues, the objectives set by its users’ intent, and the attained results in terms of public benefit.


  • Impact of Pseudo-Random Modulation on Measured Conducted EMI

    by Angel Pena-Quintal, Hermes Loschi, Robert Smolenski, Mark Sumner, Dave Thomas, Steve Greedy, Piotr Lezynski, Frank Leferink

    This paper demonstrates that using conventional frequency scanning methods for the evaluation of conducted electromagnetic interference generated by DC/DC converters can give misleading results when pseudo-random modulation is used as part of the converter control scheme. The paper therefore proposes that the resolution bandwidth of the super heterodyne EMI test receiver used for measurements and the dwell time should be adjusted to match the control parameters of the random modulation scheme. The use of different values for resolution bandwidth and dwell time is demonstrated and measurements for random and fixed modulation schemes are compared.


  • Stochastic Modelling of Power Electronic Converters under Uncertainties

    by Erjon Ballukja, Karol Niewiadomski, Angel Pena-Quintal, David W. P. Thomas, Sharmila Sumsurooah, Mark Sumner

    The aim of this paper is to explore the usage of different sampling schemes in order to build a sparse Polynomial Chaos (PC) model for prediction of the oscillation frequency and its corresponding magnitude of the output voltage in a half-bridge buck converter. The 22 parasitic elements of this converter are modelled as random variables following a uniform distribution. As a result, from the considered sampling schemes, an Latin Hypercube Sampling (LHS) and Sobol’ sequences are determined to be the best in prediction of the magnitude, both with respect to accuracy and computational time needed for the creation of the model. The introduced accuracy measure, namely the a posteriori error, shows that the PC model approximates the oscillation frequency well. However, from a visual comparison with a model obtained from 8000 Monte Carlo samples, it can be seen that the PC model is not able to handle such a complex relationship properly.

  • Sensitivity Analysis of Parasitics in Power Electronic Circuit through Sobol’ Indices

    by Karol Niewiadomski, Angel Pena-Quintal, David W.P. Thomas, Sharmila Sumsurooah

    This paper provides a sensitivity analysis of the conducted emissions from a power converter by the means of Sobol’ indices. The sensitivity measures are computed by utilizing sparse Polynomial Chaos expansions, thanks to which the number of simulations is smaller than that required by standard Polynomial Chaos methods and far smaller than in Monte Carlo approaches. The method developed in the paper quantifies the impact of parasitic elements, modeled as 18 independent random variables, on the common and differential mode voltage in the frequency range between 150 kHz and 30 MHz and consequently identifies the key influential parameters amongst all the parasitic parameters. The advantage of the approach is that it significantly reduces the complexity of the further analysis needed to reducing conducted emissions in a power electronic circuit.


  • The Influence of the Number of Frequencies and the Frequency Repetitions Rates in Spread Spectrum Sigma-Delta Modulated DC-DC Converters

    by Angel Pena-Quintal, Karol Niewiadomski, Steve Greedy, Mark Sumner, David Thomas

    This paper explores the impact of using a Spread Spectrum modulation technique based on a Sigma-Delta modulator for a DC-DC SiC-based power converter. A simple block is proposed for the PWM to generate square pulses close to 20 kHz with a controlled ramp profile. Then, different frequencies and repetition rates are used to systematically evaluate their influence of carrier related emissions. The comparison of results is carried out by measuring the peak of the switching harmonic and the average value over CISPR band A (9–150 kHz). The measurements are taken at the input voltage of the converter.


  • The Effect of Spread Spectrum Modulation for a Buck Converter Coupled with a Single Wired Communication Link

    by A. Pena-Quintal, K. Niewiadomski, V. Muneeswaran, S. Greedy, M. Sumner, D. W. P. Thomas

    This paper explores the effect of using a Spread Spectrum modulation technique with a Buck Converter on a communication cable coupled at the input voltage. The EMI created by the switching of the power converter generates damped oscillations on the data cable that can have great impact on the quality of the communication channel. Frequency domain analysis shows lower EMI levels in the power cable when compared to the standard deterministic modulation. However, there is no real improvement to the actual communications as there in an increase in the measured Bit Error Rate when evaluated experimentally.