Sukesh Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sukesh Kumar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Aimin Yu
2 shared publicationsAtul Suresh Deshpande
2 shared publicationsMudrika Khandelwal
Department of Material Science Metallurgical Engineering, IIT, Hyderabad, 502284 Telangana, India
2 shared publications- Mudrika Khandelwal
Department of Materials Science and Metallurgical Engineering, Indian Institute of Technology Hyderabad, Kandi, Hyderabad, India
2 shared publications Bhagavathi Chalil Najathulla
Cellulose & Composites Group, Department of Materials Science and Metallurgical Engineering Indian Institute of Technology Hyderabad India
1 shared publicationEkta Majhi
1 shared publication
Latest Publications
- 14 April 2025
- Published by Elsevier in Composites Part B: Engineering
- Vol. 301
Hole controlled displacement behaviour of conducting polymer actuators
- 14 April 2025
- Published by Elsevier in Composites Part B: Engineering
- Vol. 301
Hole controlled displacement behaviour of conducting polymer actuators
- Open Access
- 26 July 2024
- Published by Elsevier in Carbon Trends
- Vol. 16
Quantum capacitance: The large but hidden capacitance in supercapacitors
- 26 July 2024
- Published by Elsevier in Carbon Trends
- Vol. 16
Open AccessQuantum capacitance: The large but hidden capacitance in supercapacitors
- 13 March 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (4) , 045017
Analyzing the structural behavior of conducting polymer actuators and its interdependence with the electrochemical phenomenon
This work reports the deformation behavior of a conducting polymer, poly(3,4-ethylene dioxythiophene):polystyrene sulfonate (PEDOT:PSS)/bacterial cellulose (BC) bi-layered cantilever type actuator. Herein, it was found that the type (i.e. bending and torsion) of deformation of (PEDOT:PSS)/BC actuator was non-trivially dependent on its dimensions (width and length). Increasing the actuator’s width resulted in larger torsional deformation along the longitudinal axis against the increased area moment of inertia. The actuator with a width of 7.75 mm rotates ∼90° (i.e. the bottom cross-section) with respect to its top end. It was noticed that torsional motion dominated the deformation when the bending in the lateral direction was restricted. Further, the maximum tip displacement trivially increased with the length from 5.40 mm for an actuator of length 10 mm–12.40 mm for a length of 59.00 mm. However, the curvature of bending, which was proportional to the induced strain, was higher for smaller lengths. The change in the dimension of the actuator involves change in the stress field distribution (i.e. induced through electrochemical process) and simultaneously the resistance to deformation, resulting in a non-trivial relationship between the deformation and the dimensions. This can be advantageous from the design perspective in realizing different types of motions without incorporating additional materials. Structural theory and electrochemical impedance Spectroscopy were used to understand the mechanism of deformation dependence on the dimensions. The electrochemical impedance spectroscopy results indicated that electrolytic ions penetrate deeper into the PEDOT:PSS layer for actuators of smaller lengths. The increase in the curvature of the actuator could be explained based on the constancy of the strain produced due to the volume change per ion. The torsional motion increased because the stresses were being induced further away from the center in wider actuators. These observations and analyses reveal the interdependence of the structural behavior (i.e. dimensions) and the electrochemical phenomenon (i.e. deformation) in a conducting polymer actuator.
- 13 March 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (4) , 045017
Analyzing the structural behavior of conducting polymer actuators and its interdependence with the electrochemical phenomenon
This work reports the deformation behavior of a conducting polymer, poly(3,4-ethylene dioxythiophene):polystyrene sulfonate (PEDOT:PSS)/bacterial cellulose (BC) bi-layered cantilever type actuator. Herein, it was found that the type (i.e. bending and torsion) of deformation of (PEDOT:PSS)/BC actuator was non-trivially dependent on its dimensions (width and length). Increasing the actuator’s width resulted in larger torsional deformation along the longitudinal axis against the increased area moment of inertia. The actuator with a width of 7.75 mm rotates ∼90° (i.e. the bottom cross-section) with respect to its top end. It was noticed that torsional motion dominated the deformation when the bending in the lateral direction was restricted. Further, the maximum tip displacement trivially increased with the length from 5.40 mm for an actuator of length 10 mm–12.40 mm for a length of 59.00 mm. However, the curvature of bending, which was proportional to the induced strain, was higher for smaller lengths. The change in the dimension of the actuator involves change in the stress field distribution (i.e. induced through electrochemical process) and simultaneously the resistance to deformation, resulting in a non-trivial relationship between the deformation and the dimensions. This can be advantageous from the design perspective in realizing different types of motions without incorporating additional materials. Structural theory and electrochemical impedance Spectroscopy were used to understand the mechanism of deformation dependence on the dimensions. The electrochemical impedance spectroscopy results indicated that electrolytic ions penetrate deeper into the PEDOT:PSS layer for actuators of smaller lengths. The increase in the curvature of the actuator could be explained based on the constancy of the strain produced due to the volume change per ion. The torsional motion increased because the stresses were being induced further away from the center in wider actuators. These observations and analyses reveal the interdependence of the structural behavior (i.e. dimensions) and the electrochemical phenomenon (i.e. deformation) in a conducting polymer actuator.
- 22 March 2023
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 34 (7) , 2407-2413
PEDOT:PSS‐bacterial cellulose bilayer actuators: From the movement of ions to deflection
Here, the role of the voltage waveform and the electrolytic ions in the actuation mechanism of Poly (3,4‐ethylene dioxythiophene) polystyrene sulfonate (PEDOT:PSS)/bacterial cellulose bilayer actuator is reported. PEDOT:PSS/bacterial cellulose‐based bilayer actuator was fabricated, and its mechanism under a square and triangular wave potential at multiple frequencies was studied. The actuation was performed with HCL, KCl, and LiCl electrolytes. The deflection of the actuator was found to be dependent on the time period of the voltage waveform. The deflection for opposite biases showed frequency‐dependent asymmetry. Further, the actuator deflection was found to be related to the hydrodynamic size of cations present in electrolytes. The results indicate a cation‐dominated actuation mechanism for PEDOT:PSS/bacterial cellulose bi‐layer actuator.
- 22 March 2023
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 34 (7) , 2407-2413
PEDOT:PSS‐bacterial cellulose bilayer actuators: From the movement of ions to deflection
Here, the role of the voltage waveform and the electrolytic ions in the actuation mechanism of Poly (3,4‐ethylene dioxythiophene) polystyrene sulfonate (PEDOT:PSS)/bacterial cellulose bilayer actuator is reported. PEDOT:PSS/bacterial cellulose‐based bilayer actuator was fabricated, and its mechanism under a square and triangular wave potential at multiple frequencies was studied. The actuation was performed with HCL, KCl, and LiCl electrolytes. The deflection of the actuator was found to be dependent on the time period of the voltage waveform. The deflection for opposite biases showed frequency‐dependent asymmetry. Further, the actuator deflection was found to be related to the hydrodynamic size of cations present in electrolytes. The results indicate a cation‐dominated actuation mechanism for PEDOT:PSS/bacterial cellulose bi‐layer actuator.