Jie Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Cui has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin H. Brinkmann
Department of Neurology Mayo Clinic Rochester Minnesota USA
10 shared publications - Gregory A. Worrell
Department of Neurology Mayo Clinic Rochester Minnesota USA
9 shared publications - Nicholas M. Gregg
Department of Neurology, Mayo Clinic, Rochester, USA
5 shared publications - Brian Nils Lundstrom
Department of Neurology Mayo Clinic Rochester Minnesota USA
3 shared publications - Ewan Scott Nurse
Department of Neuroscience, School of Translational Medicine, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia
3 shared publications - Filip Mivalt
Department of Neurology, Mayo Clinic , Rochester, MN 55905
3 shared publications
Latest Publications
- Open Access
- 22 January 2026
- Published by BMJ in BMJ Neurology Open
- Vol. 8 (1) , e001403
Seizure burden and treatment efficacy evaluation in anti-LGI1 autoimmune encephalitis patients using wearable device: a pilot feasibility study
Background: Patients with anti-leucine-rich glioma-inactivated 1 (anti-LGI1) autoimmune encephalitis (AIE) frequently present with faciobrachial dystonic seizures (FBDS), which are often under-detected due to their subtle motor features and lack of consistent EEG correlates. Conventional in-hospital monitoring and patient-reported seizure diaries are limited, particularly during nocturnal periods. In this pilot feasibility study, we evaluated the use of a wearable device (Empatica E4) to objectively monitor FBDS-related motor and autonomic activity in seven patients with anti-LGI1 AIE and four control subjects. Methods: Wearable recordings included accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG) and skin temperature. A support vector machine-based algorithm was developed to identify disorder-related events using ACC and EDA features. Analyses were restricted to sleep periods to minimise confounding from voluntary movements. Results: Pretreatment recordings from two patients (P1 and P2) showed significantly elevated motor event frequency, ACC magnitude and EDA activity compared to controls. Post-treatment recordings demonstrated marked reductions in these metrics, consistent with patient-reported clinical improvement. Other patients showed variable results depending on treatment timing and signal quality. Conclusion: Our pilot study demonstrates the feasibility of using wearable technology for objective, real-world monitoring and assessment of patient status in anti-LGI1 AIE. Nocturnal monitoring offers a low-noise baseline for detecting seizure-related activity and may support earlier diagnosis, more accurate evaluation of treatment response and reduced reliance on resource-intensive inpatient evaluations. Future studies should expand monitoring to daytime periods and validate findings against conventional modalities such as video-EEG and electromyography polygraphy.
- 22 January 2026
- Published by BMJ in BMJ Neurology Open
- Vol. 8 (1) , e001403
Open AccessSeizure burden and treatment efficacy evaluation in anti-LGI1 autoimmune encephalitis patients using wearable device: a pilot feasibility study
Background: Patients with anti-leucine-rich glioma-inactivated 1 (anti-LGI1) autoimmune encephalitis (AIE) frequently present with faciobrachial dystonic seizures (FBDS), which are often under-detected due to their subtle motor features and lack of consistent EEG correlates. Conventional in-hospital monitoring and patient-reported seizure diaries are limited, particularly during nocturnal periods. In this pilot feasibility study, we evaluated the use of a wearable device (Empatica E4) to objectively monitor FBDS-related motor and autonomic activity in seven patients with anti-LGI1 AIE and four control subjects. Methods: Wearable recordings included accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG) and skin temperature. A support vector machine-based algorithm was developed to identify disorder-related events using ACC and EDA features. Analyses were restricted to sleep periods to minimise confounding from voluntary movements. Results: Pretreatment recordings from two patients (P1 and P2) showed significantly elevated motor event frequency, ACC magnitude and EDA activity compared to controls. Post-treatment recordings demonstrated marked reductions in these metrics, consistent with patient-reported clinical improvement. Other patients showed variable results depending on treatment timing and signal quality. Conclusion: Our pilot study demonstrates the feasibility of using wearable technology for objective, real-world monitoring and assessment of patient status in anti-LGI1 AIE. Nocturnal monitoring offers a low-noise baseline for detecting seizure-related activity and may support earlier diagnosis, more accurate evaluation of treatment response and reduced reliance on resource-intensive inpatient evaluations. Future studies should expand monitoring to daytime periods and validate findings against conventional modalities such as video-EEG and electromyography polygraphy.
- 19 December 2025
- Published by Elsevier in Digital Signal Processing
- Vol. 171
M2NuFFT—A computationally efficient suboptimal power spectrum estimator for fast exploration of nonuniformly sampled time series
- 19 December 2025
- Published by Elsevier in Digital Signal Processing
- Vol. 171
M2NuFFT—A computationally efficient suboptimal power spectrum estimator for fast exploration of nonuniformly sampled time series
- Open Access
Detecting Diverse Seizure Types with Wrist-Worn Wearable Devices: A Comparison of Machine Learning Approaches
Objective: To evaluate the feasibility and effectiveness of wrist-worn wearable devices combined with machine learning (ML) approaches for detecting a diverse array of seizure types beyond generalized tonic–clonic (GTC), including focal, generalized, and subclinical seizures. Materials and Methods: Twenty-eight patients undergoing inpatient video-EEG monitoring at Mayo Clinic were concurrently monitored using Empatica E4 wrist-worn devices. These devices captured accelerometry, blood volume pulse, electrodermal activity, skin temperature, and heart rate. Seizures were annotated by neurologists. The data were preprocessed to experiment with various segment lengths (10 s and 60 s) and multiple feature sets. Three ML strategies, XGBoost, deep learning models (LSTM, CNN, Transformer), and ROCKET, were evaluated using leave-one-patient-out cross-validation. Performance was assessed using area under the receiver operating characteristic curve (AUROC), seizure-wise recall (SW-Recall), and false alarms per hour (FA/h). Results: Detection performance varied by seizure type and model. GTC seizures were detected most reliably (AUROC = 0.86, SW-Recall = 0.81, FA/h = 3.03). Hyperkinetic and tonic seizures showed high SW-Recall but also high FA/h. Subclinical and aware-dyscognitive seizures exhibited the lowest SW-Recall and highest FA/h. MultiROCKET and XGBoost performed best overall, though no single model was optimal for all seizure types. Longer segments (60 s) generally reduced FA/h. Feature set effectiveness varied, with multi-biosignal sets improving performance across seizure types. Conclusions: Wrist-worn wearables combined with ML can extend seizure detection beyond GTC seizures, though performance remains limited for non-motor types. Optimizing model selection, feature sets, and segment lengths, and minimizing false alarms, are key to clinical utility and real-world adoption.
Open AccessDetecting Diverse Seizure Types with Wrist-Worn Wearable Devices: A Comparison of Machine Learning Approaches
Objective: To evaluate the feasibility and effectiveness of wrist-worn wearable devices combined with machine learning (ML) approaches for detecting a diverse array of seizure types beyond generalized tonic–clonic (GTC), including focal, generalized, and subclinical seizures. Materials and Methods: Twenty-eight patients undergoing inpatient video-EEG monitoring at Mayo Clinic were concurrently monitored using Empatica E4 wrist-worn devices. These devices captured accelerometry, blood volume pulse, electrodermal activity, skin temperature, and heart rate. Seizures were annotated by neurologists. The data were preprocessed to experiment with various segment lengths (10 s and 60 s) and multiple feature sets. Three ML strategies, XGBoost, deep learning models (LSTM, CNN, Transformer), and ROCKET, were evaluated using leave-one-patient-out cross-validation. Performance was assessed using area under the receiver operating characteristic curve (AUROC), seizure-wise recall (SW-Recall), and false alarms per hour (FA/h). Results: Detection performance varied by seizure type and model. GTC seizures were detected most reliably (AUROC = 0.86, SW-Recall = 0.81, FA/h = 3.03). Hyperkinetic and tonic seizures showed high SW-Recall but also high FA/h. Subclinical and aware-dyscognitive seizures exhibited the lowest SW-Recall and highest FA/h. MultiROCKET and XGBoost performed best overall, though no single model was optimal for all seizure types. Longer segments (60 s) generally reduced FA/h. Feature set effectiveness varied, with multi-biosignal sets improving performance across seizure types. Conclusions: Wrist-worn wearables combined with ML can extend seizure detection beyond GTC seizures, though performance remains limited for non-motor types. Optimizing model selection, feature sets, and segment lengths, and minimizing false alarms, are key to clinical utility and real-world adoption.
- Open Access
Automated Detection of Faciobrachial Dystonic Seizures Related Events in LGI1 Autoimmune Encephalitis Patients with Wearables
Objective: To evaluate the potential of wrist-worn wearable devices to detect and quantify Faciobrachial Dystonic Seizures (FBDS) and related events associated with leucine-rich glioma Inactivated-1 (LGI1)-IgG autoimmune encephalitis (LGI1 AIE). Method: Seven patients and four control subjects were monitored with Empatica E4 wristbands in both hospital and ambulatory environments. The analysis focused on the pre- and post-immunotherapy signals of accelerometry (ACC), electrodermal activity (EDA), heart rate (HR), and blood volume pulse (BVP). A two-stage semi-supervised machine learning approach was developed, utilizing a proprietary algorithm and Support Vector Machine (SVM) classifier to identify FBDS-related events. Results: Significant differences were observed in the characteristics of signals recorded in patients with FBDS compared to controls during sleep periods. LGI1 AIE-associated abnormal events were more frequent, persisted longer, and generated higher ACC amplitude compared to post-immunotherapy and arousal events in the control group. Elevated tonic and phasic EDA were noted in patients, particularly before and after immunotherapy, with a notable decrease in mean and median EDA activity post-treatment, correlating with reduced limbic activation. No significant changes were observed in HR and BVP. Significance: The findings affirm the potential for accurate and automated detection of FBDS and its related events using wearable devices, offering a non-invasive method to quantify seizure burden and treatment efficacy. This approach could minimize the logistical challenges of in-hospital monitoring and provide continuous, decentralized means, improving patient care and clinical decision-making. Future research should focus on expanding the method to daytime monitoring and comparing its effectiveness with in-hospital video-EEG and EMG polygraphy. Key points: Assessed the potential of using wearable technology to detect and monitor high-frequency Faciobrachial Dystonic Seizures (FBDS) and related events in anti-LGI1 autoimmune encephalitis. Developed a two-stage, automated machine learning algorithm to automatically isolate and classify FBDS-associated events using signals recorded with Empatica E4 wristbands. Observed significant differences in the wearable signals of patients with FBDS between pre- and post-immunotherapy, and between patient signals and normal arousal signals of the control group during sleep periods. Demonstrated the feasibility of wearable devices to provide objective measures of FBDS-related events, aiding in the quantification of treatment response and influencing clinical decision-making.
Open AccessAutomated Detection of Faciobrachial Dystonic Seizures Related Events in LGI1 Autoimmune Encephalitis Patients with Wearables
Objective: To evaluate the potential of wrist-worn wearable devices to detect and quantify Faciobrachial Dystonic Seizures (FBDS) and related events associated with leucine-rich glioma Inactivated-1 (LGI1)-IgG autoimmune encephalitis (LGI1 AIE). Method: Seven patients and four control subjects were monitored with Empatica E4 wristbands in both hospital and ambulatory environments. The analysis focused on the pre- and post-immunotherapy signals of accelerometry (ACC), electrodermal activity (EDA), heart rate (HR), and blood volume pulse (BVP). A two-stage semi-supervised machine learning approach was developed, utilizing a proprietary algorithm and Support Vector Machine (SVM) classifier to identify FBDS-related events. Results: Significant differences were observed in the characteristics of signals recorded in patients with FBDS compared to controls during sleep periods. LGI1 AIE-associated abnormal events were more frequent, persisted longer, and generated higher ACC amplitude compared to post-immunotherapy and arousal events in the control group. Elevated tonic and phasic EDA were noted in patients, particularly before and after immunotherapy, with a notable decrease in mean and median EDA activity post-treatment, correlating with reduced limbic activation. No significant changes were observed in HR and BVP. Significance: The findings affirm the potential for accurate and automated detection of FBDS and its related events using wearable devices, offering a non-invasive method to quantify seizure burden and treatment efficacy. This approach could minimize the logistical challenges of in-hospital monitoring and provide continuous, decentralized means, improving patient care and clinical decision-making. Future research should focus on expanding the method to daytime monitoring and comparing its effectiveness with in-hospital video-EEG and EMG polygraphy. Key points: Assessed the potential of using wearable technology to detect and monitor high-frequency Faciobrachial Dystonic Seizures (FBDS) and related events in anti-LGI1 autoimmune encephalitis. Developed a two-stage, automated machine learning algorithm to automatically isolate and classify FBDS-associated events using signals recorded with Empatica E4 wristbands. Observed significant differences in the wearable signals of patients with FBDS between pre- and post-immunotherapy, and between patient signals and normal arousal signals of the control group during sleep periods. Demonstrated the feasibility of wearable devices to provide objective measures of FBDS-related events, aiding in the quantification of treatment response and influencing clinical decision-making.
- 1 April 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (2) , 026022
Acute to long-term characteristics of impedance recordings during neurostimulation in humans
Objective. This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus, and posterior hippocampus over an extended period. Approach. Impedance was periodically sampled every 5–15 min over several months in five subjects with drug-resistant epilepsy using an investigational neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24 h impedance cycle throughout the multi-month recording. Main results. Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 d to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24 h impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures. Significance. Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
- 1 April 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (2) , 026022
Acute to long-term characteristics of impedance recordings during neurostimulation in humans
Objective. This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus, and posterior hippocampus over an extended period. Approach. Impedance was periodically sampled every 5–15 min over several months in five subjects with drug-resistant epilepsy using an investigational neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24 h impedance cycle throughout the multi-month recording. Main results. Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 d to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24 h impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures. Significance. Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
- Open Access
A platform for brain network sensing and stimulation with quantitative behavioral tracking: Application to limbic circuit epilepsy
Temporal lobe epilepsy is a common neurological disease characterized by recurrent seizures. These seizures often originate from limbic networks and people also experience chronic comorbidities related to memory, mood, and sleep (MMS). Deep brain stimulation targeting the anterior nucleus of the thalamus (ANT-DBS) is a proven therapy, but the optimal stimulation parameters remain unclear. We developed a neurotechnology platform for tracking seizures and MMS to enable data streaming between an investigational brain sensing-stimulation implant, mobile devices, and a cloud environment. Artificial Intelligence algorithms provided accurate catalogs of seizures, interictal epileptiform spikes, and wake-sleep brain states. Remotely administered memory and mood assessments were used to densely sample cognitive and behavioral response during ANT-DBS. We evaluated the efficacy of low-frequency versus high-frequency ANT-DBS. They both reduced seizures, but low-frequency ANT-DBS showed greater reductions and better sleep and memory. These results highlight the potential of synchronized brain sensing and behavioral tracking for optimizing neuromodulation therapy.
Open AccessA platform for brain network sensing and stimulation with quantitative behavioral tracking: Application to limbic circuit epilepsy
Temporal lobe epilepsy is a common neurological disease characterized by recurrent seizures. These seizures often originate from limbic networks and people also experience chronic comorbidities related to memory, mood, and sleep (MMS). Deep brain stimulation targeting the anterior nucleus of the thalamus (ANT-DBS) is a proven therapy, but the optimal stimulation parameters remain unclear. We developed a neurotechnology platform for tracking seizures and MMS to enable data streaming between an investigational brain sensing-stimulation implant, mobile devices, and a cloud environment. Artificial Intelligence algorithms provided accurate catalogs of seizures, interictal epileptiform spikes, and wake-sleep brain states. Remotely administered memory and mood assessments were used to densely sample cognitive and behavioral response during ANT-DBS. We evaluated the efficacy of low-frequency versus high-frequency ANT-DBS. They both reduced seizures, but low-frequency ANT-DBS showed greater reductions and better sleep and memory. These results highlight the potential of synchronized brain sensing and behavioral tracking for optimizing neuromodulation therapy.
- Open Access
Acute to long-term characteristics of impedance recordings during neurostimulation in humans
Objective This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus (AMG-HPC), and posterior hippocampus (post-HPC) over an extended period. Approach Impedance was periodically sampled every 5-15 minutes over several months in five subjects with drug-resistant epilepsy using an experimental neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24-hour impedance cycle throughout the multi-month recording. Main results Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 days to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24-hour impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures. Significance Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
Open AccessAcute to long-term characteristics of impedance recordings during neurostimulation in humans
Objective This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus (AMG-HPC), and posterior hippocampus (post-HPC) over an extended period. Approach Impedance was periodically sampled every 5-15 minutes over several months in five subjects with drug-resistant epilepsy using an experimental neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24-hour impedance cycle throughout the multi-month recording. Main results Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 days to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24-hour impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures. Significance Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
Perceived seizure risk in epilepsy: Chronic electronic surveys with and without concurrent electroencephalography
Objective: Previous studies suggested that patients with epilepsy might be able to forecast their own seizures. This study aimed to assess the relationships between premonitory symptoms, perceived seizure risk, and future and recent self‐reported and electroencephalographically (EEG)‐confirmed seizures in ambulatory patients with epilepsy in their natural home environments.Methods: Long‐term e‐surveys were collected from patients with and without concurrent EEG recordings. Information obtained from the e‐surveys included medication adherence, sleep quality, mood, stress, perceived seizure risk, and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed‐effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with the seizure forecasting classifiers and device forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC).Results: Fifty‐four subjects returned 10 269 e‐survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed that increased stress (OR = 2.01, 95% confidence interval [CI] = 1.12–3.61, AUC = .61, p = .02) was associated with increased relative odds of future self‐reported seizures. Multivariate analysis showed that previous self‐reported seizures (OR = 5.37, 95% CI = 3.53–8.16, AUC = .76, p < .001) were most strongly associated with future self‐reported seizures, and high perceived seizure risk (OR = 3.34, 95% CI = 1.87–5.95, AUC = .69, p < .001) remained significant when prior self‐reported seizures were added to the model. No correlation with medication adherence was found. No significant association was found between e‐survey responses and subsequent EEG seizures.Significance: Our results suggest that patients may tend to self‐forecast seizures that occur in sequential groupings and that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self‐predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting.
Perceived seizure risk in epilepsy: Chronic electronic surveys with and without concurrent electroencephalography
Objective: Previous studies suggested that patients with epilepsy might be able to forecast their own seizures. This study aimed to assess the relationships between premonitory symptoms, perceived seizure risk, and future and recent self‐reported and electroencephalographically (EEG)‐confirmed seizures in ambulatory patients with epilepsy in their natural home environments.Methods: Long‐term e‐surveys were collected from patients with and without concurrent EEG recordings. Information obtained from the e‐surveys included medication adherence, sleep quality, mood, stress, perceived seizure risk, and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed‐effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with the seizure forecasting classifiers and device forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC).Results: Fifty‐four subjects returned 10 269 e‐survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed that increased stress (OR = 2.01, 95% confidence interval [CI] = 1.12–3.61, AUC = .61, p = .02) was associated with increased relative odds of future self‐reported seizures. Multivariate analysis showed that previous self‐reported seizures (OR = 5.37, 95% CI = 3.53–8.16, AUC = .76, p < .001) were most strongly associated with future self‐reported seizures, and high perceived seizure risk (OR = 3.34, 95% CI = 1.87–5.95, AUC = .69, p < .001) remained significant when prior self‐reported seizures were added to the model. No correlation with medication adherence was found. No significant association was found between e‐survey responses and subsequent EEG seizures.Significance: Our results suggest that patients may tend to self‐forecast seizures that occur in sequential groupings and that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self‐predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting.
Seizure occurrence is linked to multiday cycles in diverse physiological signals
Objective: The factors that influence seizure timing are poorly understood, and seizure unpredictability remains a major cause of disability. Work in chronobiology has shown that cyclical physiological phenomena are ubiquitous, with daily and multiday cycles evident in immune, endocrine, metabolic, neurological, and cardiovascular function. Additionally, work with chronic brain recordings has identified that seizure risk is linked to daily and multiday cycles in brain activity. Here, we provide the first characterization of the relationships between the cyclical modulation of a diverse set of physiological signals, brain activity, and seizure timing.Methods: In this cohort study, 14 subjects underwent chronic ambulatory monitoring with a multimodal wrist‐worn sensor (recording heart rate, accelerometry, electrodermal activity, and temperature) and an implanted responsive neurostimulation system (recording interictal epileptiform abnormalities and electrographic seizures). Wavelet and filter–Hilbert spectral analyses characterized circadian and multiday cycles in brain and wearable recordings. Circular statistics assessed electrographic seizure timing and cycles in physiology.Results: Ten subjects met inclusion criteria. The mean recording duration was 232 days. Seven subjects had reliable electroencephalographic seizure detections (mean = 76 seizures). Multiday cycles were present in all wearable device signals across all subjects. Seizure timing was phase locked to multiday cycles in five (temperature), four (heart rate, phasic electrodermal activity), and three (accelerometry, heart rate variability, tonic electrodermal activity) subjects. Notably, after regression of behavioral covariates from heart rate, six of seven subjects had seizure phase locking to the residual heart rate signal.Significance: Seizure timing is associated with daily and multiday cycles in multiple physiological processes. Chronic multimodal wearable device recordings can situate rare paroxysmal events, like seizures, within a broader chronobiology context of the individual. Wearable devices may advance the understanding of factors that influence seizure risk and enable personalized time‐varying approaches to epilepsy care.
Seizure occurrence is linked to multiday cycles in diverse physiological signals
Objective: The factors that influence seizure timing are poorly understood, and seizure unpredictability remains a major cause of disability. Work in chronobiology has shown that cyclical physiological phenomena are ubiquitous, with daily and multiday cycles evident in immune, endocrine, metabolic, neurological, and cardiovascular function. Additionally, work with chronic brain recordings has identified that seizure risk is linked to daily and multiday cycles in brain activity. Here, we provide the first characterization of the relationships between the cyclical modulation of a diverse set of physiological signals, brain activity, and seizure timing.Methods: In this cohort study, 14 subjects underwent chronic ambulatory monitoring with a multimodal wrist‐worn sensor (recording heart rate, accelerometry, electrodermal activity, and temperature) and an implanted responsive neurostimulation system (recording interictal epileptiform abnormalities and electrographic seizures). Wavelet and filter–Hilbert spectral analyses characterized circadian and multiday cycles in brain and wearable recordings. Circular statistics assessed electrographic seizure timing and cycles in physiology.Results: Ten subjects met inclusion criteria. The mean recording duration was 232 days. Seven subjects had reliable electroencephalographic seizure detections (mean = 76 seizures). Multiday cycles were present in all wearable device signals across all subjects. Seizure timing was phase locked to multiday cycles in five (temperature), four (heart rate, phasic electrodermal activity), and three (accelerometry, heart rate variability, tonic electrodermal activity) subjects. Notably, after regression of behavioral covariates from heart rate, six of seven subjects had seizure phase locking to the residual heart rate signal.Significance: Seizure timing is associated with daily and multiday cycles in multiple physiological processes. Chronic multimodal wearable device recordings can situate rare paroxysmal events, like seizures, within a broader chronobiology context of the individual. Wearable devices may advance the understanding of factors that influence seizure risk and enable personalized time‐varying approaches to epilepsy care.
- Open Access
Perceived seizure risk in epilepsy – Chronic electronic surveys with and without concurrent EEG
Objective: Previous studies suggested that patients with epilepsy might be able to fore-cast their own seizures. We sought to assess the relationships of premonitory symptoms and perceived seizure risk with future and recent self-reported and EEG-confirmed seizures in the subjects living with epilepsy in their natural home environments. Methods: We collected long-term e-surveys from ambulatory patients with and without concurrent EEG recordings. Information obtained from the e-surveys included medication compliance, sleep quality, mood, stress, perceived seizure risk and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed-effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with device seizure forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC). Results: Sixty-nine subjects returned 12,590 e-survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed increased stress (OR = 2.52, 95% CI = [1.52, 4.14], p < 0.001) and decreased mood (0.32, [0.13, 0.82], 0.02) were associated with increased relative odds of future self-reported seizures. On multivariate analysis, previous self-reported seizures (4.24, [2.69, 6.68], < 0.001) were most strongly associated with future self-reported seizures, and high perceived seizure risk (3.30, [1.97, 5.52], < 0.001) remained significant when prior self-reported seizures were added to the model. No significant association was found between e-survey responses and subsequent EEG seizures. Significance: It appears that patients may tend to self-forecast seizures that occur in sequential groupings. Our results suggest that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self-predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting. Key points: Long-term e-surveys data and concurrent EEG signals were collected across three study sites to assess the ability of the patients to self-forecast their seizures. Patients may tend to self-forecast self-reported seizures that occur in sequential groupings. Factors, such as mood and stress, may not be independent premonitory symptoms but may be the consequence of recent seizures. No ability to self-forecast EEG confirmed seizures was observed in a small cohort with concurrent EEG validation. A mathematic relation between OR and AUC provides a means to compare forecasting performance between survey and device studies.
Open AccessPerceived seizure risk in epilepsy – Chronic electronic surveys with and without concurrent EEG
Objective: Previous studies suggested that patients with epilepsy might be able to fore-cast their own seizures. We sought to assess the relationships of premonitory symptoms and perceived seizure risk with future and recent self-reported and EEG-confirmed seizures in the subjects living with epilepsy in their natural home environments. Methods: We collected long-term e-surveys from ambulatory patients with and without concurrent EEG recordings. Information obtained from the e-surveys included medication compliance, sleep quality, mood, stress, perceived seizure risk and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed-effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with device seizure forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC). Results: Sixty-nine subjects returned 12,590 e-survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed increased stress (OR = 2.52, 95% CI = [1.52, 4.14], p < 0.001) and decreased mood (0.32, [0.13, 0.82], 0.02) were associated with increased relative odds of future self-reported seizures. On multivariate analysis, previous self-reported seizures (4.24, [2.69, 6.68], < 0.001) were most strongly associated with future self-reported seizures, and high perceived seizure risk (3.30, [1.97, 5.52], < 0.001) remained significant when prior self-reported seizures were added to the model. No significant association was found between e-survey responses and subsequent EEG seizures. Significance: It appears that patients may tend to self-forecast seizures that occur in sequential groupings. Our results suggest that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self-predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting. Key points: Long-term e-surveys data and concurrent EEG signals were collected across three study sites to assess the ability of the patients to self-forecast their seizures. Patients may tend to self-forecast self-reported seizures that occur in sequential groupings. Factors, such as mood and stress, may not be independent premonitory symptoms but may be the consequence of recent seizures. No ability to self-forecast EEG confirmed seizures was observed in a small cohort with concurrent EEG validation. A mathematic relation between OR and AUC provides a means to compare forecasting performance between survey and device studies.