Anna S. Makarova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna S. Makarova has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Elena N. Bocharnikova
National Research Tomsk State University, Tomsk, Russia
3 shared publications - Olga N. Tchaikovskaya
Laboratory of Quantum Electronics, Institute of Electrophysics of the Ural Branch of the Russian Academy of Sciences, Yekaterinburg, Russian Federation
3 shared publications - Vladimir I. Solomonov
Institute of Electrophysics, Ural Branch, Russian Academy of Sciences, Yekaterinburg, Russia
3 shared publications - A. V. Spirina
Institute of Electrophysics, Ural Branch of the Russian Academy of Sciences, Ekaterinburg, Russia
2 shared publications - Alexander I. Lipchak
Institute of Electrophysics, Ural Branch, Russian Academy of Sciences, Yekaterinburg, Russia
2 shared publications - Stanislav A. Chaikovsky
Institute of Electrophysics, Ural Branch, Russian Academy of Sciences, Yekaterinburg, Russia
2 shared publications
Latest Publications
- Open Access
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1756-1763
Induced Transformation of Chloramphenicol under Pulsed Electron Beam Irradiation
The radiation-induced transformations of chloramphenicol immobilized on a silica gel substrate under the action of a pulsed electron beam is studied. The experiment is performed using the CLAVI setup (Institute of Electrophysics, Ural Branch of the Russian Academy of Sciences, Yekaterinburg). Chloramphenicol samples is applied to thin layer chromatography (TLC) plates. Electron beam parameters is varied using aluminum foil placed in front of the sample substrate. After irradiation, solid-phase extraction of the substance from the plate surface is performed with distilled water and ethyl alcohol. The resulting solutions are analyzed using spectroscopy, reaction with the Folin–Ciocalteu phenol reagent, and TLC. It was shown that irradiation with an electron beam (170 keV) leads to the degradation of chloramphenicol with the formation of new compounds, including phenolic derivatives. After 1600 electron beam pulses, the chloramphenicol residue was 77.6% with the foil and 46.3% without the foil. Emitting products in the ranges of 330, 410, and 450 nm were isolated using fluorescence. These data demonstrate the high reactivity of chloramphenicol in a solid-phase system under the influence of electron beams and open prospects for the development of radiation-based methods for the degradation of solid pharmaceutical contaminants.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1756-1763
Open AccessInduced Transformation of Chloramphenicol under Pulsed Electron Beam Irradiation
The radiation-induced transformations of chloramphenicol immobilized on a silica gel substrate under the action of a pulsed electron beam is studied. The experiment is performed using the CLAVI setup (Institute of Electrophysics, Ural Branch of the Russian Academy of Sciences, Yekaterinburg). Chloramphenicol samples is applied to thin layer chromatography (TLC) plates. Electron beam parameters is varied using aluminum foil placed in front of the sample substrate. After irradiation, solid-phase extraction of the substance from the plate surface is performed with distilled water and ethyl alcohol. The resulting solutions are analyzed using spectroscopy, reaction with the Folin–Ciocalteu phenol reagent, and TLC. It was shown that irradiation with an electron beam (170 keV) leads to the degradation of chloramphenicol with the formation of new compounds, including phenolic derivatives. After 1600 electron beam pulses, the chloramphenicol residue was 77.6% with the foil and 46.3% without the foil. Emitting products in the ranges of 330, 410, and 450 nm were isolated using fluorescence. These data demonstrate the high reactivity of chloramphenicol in a solid-phase system under the influence of electron beams and open prospects for the development of radiation-based methods for the degradation of solid pharmaceutical contaminants.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (5) , 1191-1198
Excitation of Pulsed Cathodoluminescence by Picosecond Beams of Runaway Electrons
When excited by beams of runaway electrons with a duration of 100 ps, the pulsed cathodoluminescence of alkali halide crystals, cerium-doped yttrium-aluminum garnet ceramics, and synthetic gems (ruby, sapphire and diamond) was studied. The runaway electron beams were generated in the cathode-anode gap filled with atmospheric pressure air and focused by a non-uniform magnetic field with an amplitude of B ≈ 0.6 T into an area with a diameter of 15 mm. A comparative analysis was carried out between the findings and pulsed cathodoluminescence parameters of the same samples excited by an electron beam with a duration of 2 ns and a current density of 130 A/cm2 generated in a vacuum diode. In the case of irradiation with the runaway electron beams, the formation of F-centers has not been observed in alkali halide crystals, that arises out of a reduced radiation impact on samples. Thus, the spectral information is not distorted. When excited by a picosecond runaway electron beam, the decay kinetics of the Ce3+ luminescence band in yttrium-aluminum garnet ceramics is described by an exponential function with a characteristic time of 100 ns. When the ceramics are irradiated with a nanosecond electron beam with a higher fluence, the kinetic curve has a more complex shape with an additional maximum in the microsecond range due to the appearance of an extra pumping mechanism for the cerium emissive level. The luminescence spectra and kinetic parameters of the synthetic gems are identical in both cases. The difference is manifested only in the emission intensity, which is much weaker when samples are exposed to irradiation with picosecond runaway electron beams.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (5) , 1191-1198
Excitation of Pulsed Cathodoluminescence by Picosecond Beams of Runaway Electrons
When excited by beams of runaway electrons with a duration of 100 ps, the pulsed cathodoluminescence of alkali halide crystals, cerium-doped yttrium-aluminum garnet ceramics, and synthetic gems (ruby, sapphire and diamond) was studied. The runaway electron beams were generated in the cathode-anode gap filled with atmospheric pressure air and focused by a non-uniform magnetic field with an amplitude of B ≈ 0.6 T into an area with a diameter of 15 mm. A comparative analysis was carried out between the findings and pulsed cathodoluminescence parameters of the same samples excited by an electron beam with a duration of 2 ns and a current density of 130 A/cm2 generated in a vacuum diode. In the case of irradiation with the runaway electron beams, the formation of F-centers has not been observed in alkali halide crystals, that arises out of a reduced radiation impact on samples. Thus, the spectral information is not distorted. When excited by a picosecond runaway electron beam, the decay kinetics of the Ce3+ luminescence band in yttrium-aluminum garnet ceramics is described by an exponential function with a characteristic time of 100 ns. When the ceramics are irradiated with a nanosecond electron beam with a higher fluence, the kinetic curve has a more complex shape with an additional maximum in the microsecond range due to the appearance of an extra pumping mechanism for the cerium emissive level. The luminescence spectra and kinetic parameters of the synthetic gems are identical in both cases. The difference is manifested only in the emission intensity, which is much weaker when samples are exposed to irradiation with picosecond runaway electron beams.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (S2) , S217-S221
Effects of a High-Intensity Electron Beam on Antibiotic in Aqueous Solution
The accurate sensitive analysis of drugs in environmental samples, as well as the removal of these substances from natural and waste waters, is the great importance for maintaining viability. Sulfaguanidine is a widely used antibiotic. Registration of absorption and fluorescence spectra, spectra of pulsed cathodoluminescence in the region from 350 to 900 nm under irradiation with electron beams with a duration of 2 ns and an average energy of 170 keV was carried out to study the transformation of sulfaguanidine in water. It has been shown that this treatment of the solution results in the transformation of the sulfaguanidine molecule. Irradiation of the solution and excitation of pulsed cathodoluminescence of the boundary layer of air localized near the surface of the solution were carried out simultaneously by the same electron beam. The degree of antibiotic transformation under the action of an electron beam was determined from the change in the luminescence and absorption spectra of the irradiated solution. As a result, we recorded the utilization of dissolved sulfaguanidine, which means the neutralization of the solution. Thus, after electron irradiation, the toxicological effects of sulfonamide antibiotics decrease.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (S2) , S217-S221
Effects of a High-Intensity Electron Beam on Antibiotic in Aqueous Solution
The accurate sensitive analysis of drugs in environmental samples, as well as the removal of these substances from natural and waste waters, is the great importance for maintaining viability. Sulfaguanidine is a widely used antibiotic. Registration of absorption and fluorescence spectra, spectra of pulsed cathodoluminescence in the region from 350 to 900 nm under irradiation with electron beams with a duration of 2 ns and an average energy of 170 keV was carried out to study the transformation of sulfaguanidine in water. It has been shown that this treatment of the solution results in the transformation of the sulfaguanidine molecule. Irradiation of the solution and excitation of pulsed cathodoluminescence of the boundary layer of air localized near the surface of the solution were carried out simultaneously by the same electron beam. The degree of antibiotic transformation under the action of an electron beam was determined from the change in the luminescence and absorption spectra of the irradiated solution. As a result, we recorded the utilization of dissolved sulfaguanidine, which means the neutralization of the solution. Thus, after electron irradiation, the toxicological effects of sulfonamide antibiotics decrease.
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (10) , 2765-2770
The Testing Equipment for Electron-Beam Exposure to Solutions of Organic Compounds
Electron beam irradiation is of great interest to researchers as it opens up new opportunities for meaningful interdisciplinary collaboration between scientists from fields such as chemistry, physics, ecology, engineering, biology, nanotechnology, and materials science. The interaction of electrons with matter ensures the formation of highly efficient reactive particles. A setup for studying the interaction of an electron beam with a liquid is presented. The efficiency of transformation of dissolved organic compounds under the action of electron beam irradiation was evaluated using pulsed cathodoluminescence. The novelty of the study lies in the fact that the irradiation of solutions and the excitation of luminescence, which is used for diagnostics, are carried out simultaneously by the same electron beam. This setup is a tool for studying the physicochemical utilization of toxic dissolved compounds. The decay process, stimulated by pulsed electron beams from 50 to 3200 pulses, proceeded intensively in aqueous solutions with the addition of crystal violet or bisphenol A. Some of the transformation products were emitted into the air, changing the composition and intensity of its luminescence. The conversion of the studied compounds was carried out using electron absorption spectroscopy and stationary fluorescence.
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (10) , 2765-2770
The Testing Equipment for Electron-Beam Exposure to Solutions of Organic Compounds
Electron beam irradiation is of great interest to researchers as it opens up new opportunities for meaningful interdisciplinary collaboration between scientists from fields such as chemistry, physics, ecology, engineering, biology, nanotechnology, and materials science. The interaction of electrons with matter ensures the formation of highly efficient reactive particles. A setup for studying the interaction of an electron beam with a liquid is presented. The efficiency of transformation of dissolved organic compounds under the action of electron beam irradiation was evaluated using pulsed cathodoluminescence. The novelty of the study lies in the fact that the irradiation of solutions and the excitation of luminescence, which is used for diagnostics, are carried out simultaneously by the same electron beam. This setup is a tool for studying the physicochemical utilization of toxic dissolved compounds. The decay process, stimulated by pulsed electron beams from 50 to 3200 pulses, proceeded intensively in aqueous solutions with the addition of crystal violet or bisphenol A. Some of the transformation products were emitted into the air, changing the composition and intensity of its luminescence. The conversion of the studied compounds was carried out using electron absorption spectroscopy and stationary fluorescence.