Cong Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cong Sun has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chuang Liu
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Northeast Electric Power University, Jilin 132012, China
3 shared publications - Heling Yang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Northeast Electric Power University, Jilin 132012, China
2 shared publications - Guoqing Liu
State Grid Zhejiang Electric Power Company Limited Hangzhou Fuyang District Power Supply Company, Hangzhou 311400, China
1 shared publication Hongkang Zhu
Northeast Electric Power University
1 shared publicationJianfei Chi
State Grid Zhejiang Electric Power Company Limited Hangzhou Fuyang District Power Supply Company
1 shared publication- Junrui Chen
Department of Communication Engineering, Northeast Electric Power University, Jilin 132013, China
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3286 (1)
Resonance Suppression Strategy for Grid-Connected Photovoltaic Systems Based on Adaptive Bandpass Filter
Nowadays, new energy power is developing rapidly across the globe. With an increasing number of new energy generation systems integrated into the power grid, a large number of broadband resonance phenomena emerge during their operation. Hence, fast and effective resonance suppression strategies are of great importance. This paper proposes a resonance suppression strategy for grid-connected photovoltaic (PV) systems based on an adaptive bandpass filter. Firstly, the Estimation of Signal Parameters via Rotational Invariance Techniques (ESPRIT) is adopted to accurately identify the resonant frequency components, the corresponding individual harmonic distortion (IHD) rates, and the total harmonic distortion (THD) in real-time. Secondly, a parameter-adaptive bandpass filter is designed based on the identified resonance parameters, which maximizes the feedback of dominant resonance components while minimizing the loss of fundamental-frequency components. Finally, the effectiveness and feasibility of the proposed resonance suppression strategy are verified through a simulation case of an LCL (Inductor-Capacitor-Inductor)-filter-based grid-connected PV system. The results demonstrate that the proposed strategy can rapidly suppress broadband resonance, reducing the system THD from 37.88% to approximately 1%, and effectively eliminating key resonant components. This work, characterized by fast response, high-precision parameter identification, and dynamic adaptability, provides a new perspective and practical technical support for online wide-band resonance monitoring and the design of suppression strategies in modern power systems.
- 1 July 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3286 (1)
Open AccessResonance Suppression Strategy for Grid-Connected Photovoltaic Systems Based on Adaptive Bandpass Filter
Nowadays, new energy power is developing rapidly across the globe. With an increasing number of new energy generation systems integrated into the power grid, a large number of broadband resonance phenomena emerge during their operation. Hence, fast and effective resonance suppression strategies are of great importance. This paper proposes a resonance suppression strategy for grid-connected photovoltaic (PV) systems based on an adaptive bandpass filter. Firstly, the Estimation of Signal Parameters via Rotational Invariance Techniques (ESPRIT) is adopted to accurately identify the resonant frequency components, the corresponding individual harmonic distortion (IHD) rates, and the total harmonic distortion (THD) in real-time. Secondly, a parameter-adaptive bandpass filter is designed based on the identified resonance parameters, which maximizes the feedback of dominant resonance components while minimizing the loss of fundamental-frequency components. Finally, the effectiveness and feasibility of the proposed resonance suppression strategy are verified through a simulation case of an LCL (Inductor-Capacitor-Inductor)-filter-based grid-connected PV system. The results demonstrate that the proposed strategy can rapidly suppress broadband resonance, reducing the system THD from 37.88% to approximately 1%, and effectively eliminating key resonant components. This work, characterized by fast response, high-precision parameter identification, and dynamic adaptability, provides a new perspective and practical technical support for online wide-band resonance monitoring and the design of suppression strategies in modern power systems.
- Open Access
Performance and Robustness Evaluation of the Resonance Suppression Strategy for the Photovoltaic Grid-Connected System Based on the Entropy Weight Method
There are numerous broadband resonance phenomena during the operation of new energy grid-connected systems. Therefore, the performance and adaptability of resonance suppression strategies for different resonance scenarios are of great significance. This paper proposed a comprehensive evaluation method based on the entropy weight method to assess the performance and robustness of resonance suppression strategies for photovoltaic (PV) grid-connected systems. Corresponding performance indicators were constructed considering the dynamic response characteristics of PV grid-connected systems. The six suppression strategies were comparatively analyzed in terms of performance and robustness under three scenarios: the LCL (inductor–capacitor–inductor)-type PV grid-connected system, the PV grid-connected system with SVG, and the newly built PV grid-connected system with SVG. This work effectively evaluates the performance and robustness of different suppression strategies, identifies the deficiencies of individual strategies, and provides a theoretical basis for designing flexible resonance suppression strategies with parameter adaptability.
Open AccessPerformance and Robustness Evaluation of the Resonance Suppression Strategy for the Photovoltaic Grid-Connected System Based on the Entropy Weight Method
There are numerous broadband resonance phenomena during the operation of new energy grid-connected systems. Therefore, the performance and adaptability of resonance suppression strategies for different resonance scenarios are of great significance. This paper proposed a comprehensive evaluation method based on the entropy weight method to assess the performance and robustness of resonance suppression strategies for photovoltaic (PV) grid-connected systems. Corresponding performance indicators were constructed considering the dynamic response characteristics of PV grid-connected systems. The six suppression strategies were comparatively analyzed in terms of performance and robustness under three scenarios: the LCL (inductor–capacitor–inductor)-type PV grid-connected system, the PV grid-connected system with SVG, and the newly built PV grid-connected system with SVG. This work effectively evaluates the performance and robustness of different suppression strategies, identifies the deficiencies of individual strategies, and provides a theoretical basis for designing flexible resonance suppression strategies with parameter adaptability.
- Open Access
Design and Optimization of a High-Frequency Oscillation Suppression Strategy for the Grid-Connected Inverter of a Permanent Magnet Direct Drive Wind Turbine
With the development of the new power system with a high proportion of new energy and a high proportion of power electronic equipment, various problems caused by high-frequency oscillation will seriously affect the daily normal operation of the power system. For the existing active oscillatory suppression strategies, the impedance characteristics of other frequency bands will be affected, which may cause new oscillation problems in other frequency bands, namely the negative effect of oscillatory suppression strategy. In response to such phenomena, we conducted research on the mechanism of negative effects and optimize the control strategies accordingly. First, an analysis model of the grid-connected inverter was established. The concept of the damping factor was proposed based on the relationship between passive damping and active damping. The feasibility of the oscillation suppression mechanism based on the damping factor was demonstrated, and the negative effect mechanism of the oscillation suppression strategy was clarified. Secondly, a control strategy based on the superposition of active damping was proposed, which not only solved the negative effect of the oscillation suppression strategy but also avoided the shift of the inherent resonance point. Finally, the theory was verified based on the MATLAB R2022a/Simulink simulation platform.
Open AccessDesign and Optimization of a High-Frequency Oscillation Suppression Strategy for the Grid-Connected Inverter of a Permanent Magnet Direct Drive Wind Turbine
With the development of the new power system with a high proportion of new energy and a high proportion of power electronic equipment, various problems caused by high-frequency oscillation will seriously affect the daily normal operation of the power system. For the existing active oscillatory suppression strategies, the impedance characteristics of other frequency bands will be affected, which may cause new oscillation problems in other frequency bands, namely the negative effect of oscillatory suppression strategy. In response to such phenomena, we conducted research on the mechanism of negative effects and optimize the control strategies accordingly. First, an analysis model of the grid-connected inverter was established. The concept of the damping factor was proposed based on the relationship between passive damping and active damping. The feasibility of the oscillation suppression mechanism based on the damping factor was demonstrated, and the negative effect mechanism of the oscillation suppression strategy was clarified. Secondly, a control strategy based on the superposition of active damping was proposed, which not only solved the negative effect of the oscillation suppression strategy but also avoided the shift of the inherent resonance point. Finally, the theory was verified based on the MATLAB R2022a/Simulink simulation platform.
- Open Access
Adaptive Band-Pass Filter and VMD-Esprit Based Multi-Mode Monitoring Method for Broadband Electromagnetic Oscillation in “Double High” Power Systems
With the development of new power systems with high proportions of renewable energy and high proportions of power electronics equipment, the influence of broadband electromagnetic oscillations in power systems is becoming more and more significant. In order to better grasp the dynamic characteristics of broadband oscillations, a new adaptive band-pass filter and VMD-Esprit based multi-modal monitoring method is proposed for broadband electromagnetic oscillation in “double high” power systems. First, based on the mode frequency and amplitude information provided by FFT mode detection, the proposed adaptive band-pass filter adaptively sets the center frequency, bandwidth, and other parameters and extracts or separates the voltage/current signal in each frequency band. Second, the filtered signals are corrected and compensated, and then the VMD modal decomposition of each frequency band signal is combined with Esprit for parameter identification so as to obtain the waveform and parameter information of each mode. Finally, the separation, correction, and parameter identification of multi-mode broadband oscillation waveforms are carried out. The experimental results show that frequency division processing can reduce the computation and improve real-time performance. In the processing of signals in the frequency band, the center frequency, bandwidth, and other parameters can be adjusted adaptively under different conditions of single-mode composition or multi-mode composition, which improves the accuracy of VMD decomposition and increases the flexibility of signal processing. Meanwhile, it overcomes the defects such as the inaccuracy of traditional mode recognition, which provides a new idea for broadband electromagnetic oscillation analysis.
Open AccessAdaptive Band-Pass Filter and VMD-Esprit Based Multi-Mode Monitoring Method for Broadband Electromagnetic Oscillation in “Double High” Power Systems
With the development of new power systems with high proportions of renewable energy and high proportions of power electronics equipment, the influence of broadband electromagnetic oscillations in power systems is becoming more and more significant. In order to better grasp the dynamic characteristics of broadband oscillations, a new adaptive band-pass filter and VMD-Esprit based multi-modal monitoring method is proposed for broadband electromagnetic oscillation in “double high” power systems. First, based on the mode frequency and amplitude information provided by FFT mode detection, the proposed adaptive band-pass filter adaptively sets the center frequency, bandwidth, and other parameters and extracts or separates the voltage/current signal in each frequency band. Second, the filtered signals are corrected and compensated, and then the VMD modal decomposition of each frequency band signal is combined with Esprit for parameter identification so as to obtain the waveform and parameter information of each mode. Finally, the separation, correction, and parameter identification of multi-mode broadband oscillation waveforms are carried out. The experimental results show that frequency division processing can reduce the computation and improve real-time performance. In the processing of signals in the frequency band, the center frequency, bandwidth, and other parameters can be adjusted adaptively under different conditions of single-mode composition or multi-mode composition, which improves the accuracy of VMD decomposition and increases the flexibility of signal processing. Meanwhile, it overcomes the defects such as the inaccuracy of traditional mode recognition, which provides a new idea for broadband electromagnetic oscillation analysis.