SLShengjie Li

Shengjie Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shengjie Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Breaking the Relevance–Diversity Seesaw: Hierarchical LLM Reasoning with RL for Industrial Novelty Recommendation

    by Ying Sun, Yanyan Zou, Xiao Wang, Hanchuan Xu, Xuanhua Yang, Sulong Xu, Junbo Qi, Shengjie Li

  • Open Access

    Adaptive Mix Preference Optimization for Generative Recommendation

    by Junbo Qi, Yanyan Zou, Xuanhua Yang, Sulong Xu, Ying Sun, Shengjie Li

  • Open Access

    GenRec: A Preference-Oriented Generative Framework for Large-Scale Recommendation

    by Yanyan Zou, Junbo Qi, Lunsong Huang, Yu Li, Kewei Xu, Jiahao Gao, Binglei Zhao, Xuanhua Yang, Sulong Xu, Shengjie Li


  • Open Access

    WiLife: Long-Term Daily Status Monitoring and Habit Mining of the Elderly Leveraging Ubiquitous Wi-Fi Signals

    by Shengjie Li, Zhaopeng Liu, Qin Lv, Yanyan Zou, Yue Zhang, Daqing Zhang

    The global aging demographic underscores the imperative for continuous in-home monitoring of the empty-nest elderly, ensuring their safety and well-being. The widespread deployment of Wi-Fi infrastructure has paved the way to monitor the elderly in a non-intrusive and privacy-preserving manner. Numerous studies have explored the potential of utilizing Wi-Fi signals to address urgent life safety concerns such as fall detection and vital sign monitoring. However, apart from these acute safety issues, the early detection of potential disease symptoms and managing the progression of chronic diseases are also crucial for elderly care, which calls for long-term and continuous monitoring of the elderly’s daily routines. Unfortunately, challenges like continuous activity segmentation and location/orientation dependencies have hindered the implementation of a long-term, around-the-clock activity monitoring system for the elderly. This work introduces “WiLife,” a cutting-edge Wi-Fi-based framework for continuous monitoring of the elderly’s spatio-temporal daily status information. Specifically, WiLife adopts a strategy of partitioning living spaces into functional areas and categorizing daily activities into atomic states . By encapsulating daily life status into a unique series of triple unit format: \(\left\langle\textit{Time, Area, State}\right\rangle\) , WiLife is able to offer valuable insights into when, where, and how activities occur. Field implementations spanning 1,080 hours (45 days \(\times\) 24 hours) in real-world home environments highlight WiLife’s exceptional capability in understanding individual living habits and timely detection of irregularities.


  • Open Access

    AudioGuard: Omnidirectional Indoor Intrusion Detection Using Audio Device

    by Tianben Wang, Zhangben Li, Honghao Yan, Xiantao Liu, Boqin Liu, Shengjie Li, Zhongyu Ma, Jin Hu, Daqing Zhang, Tao Gu

    Indoor intrusion detection is a critical task for home security. Previous works in intrusion detection suffer from the problems such as blind spots in non-line-of-sight (NLOS) areas, restricted device locations, massive offline training required, and privacy concern. In this article, we design and implement an omnidirectional indoor intrusion detection system, named AudioGuard , using only a pair of speaker and microphone. AudioGuard is able to detect both line-of-sight (LOS) and NLOS intrusions. Our observation of acoustic signal propagation in an indoor environment shows that there exist abundant multipath reflections and human movement introduces Doppler shift in echo signals. We hence capture periodical Doppler shift caused by intruder's walking motion to detect intrusion. Specifically, we first extract the Doppler shift embedded in echo signals, and we then propose a periodicity polarization method to cancel out the impact of the change of radial angle and the distance on periodicity of Doppler shift. Finally, we detect intrusion by measuring periodicity of Doppler shift over time. Extensive experiments show that AudioGuard achieves a miss report rate of 0% and 1.75% for LOS and NLOS intrusion, respectively, and a false alarm rate of 4.17%.


  • Open Access

    LT-Fall

    by Duo Zhang, Xusheng Zhang, Shengjie Li, Yaxiong Xie, Yang Li, Xuanzhi Wang, Daqing Zhang

    Falls are the leading cause of fatal injuries to elders in modern society, which has motivated researchers to propose various fall detection technologies. We observe that most of the existing fall detection solutions are diverging from the purpose of fall detection: timely alarming the family members, medical staff or first responders to save the life of the human with severe injury caused by fall. Instead, they focus on detecting the behavior of human falls, which does not necessarily mean a human is in real danger. The real critical situation is when a human cannot get up without assistance and is thus lying on the ground after the fall because of losing consciousness or becoming incapacitated due to severe injury. In this paper, we define a life-threatening fall as a behavior that involves a falling down followed by a long-lie of humans on the ground, and for the first time point out that a fall detection system should focus on detecting life-threatening falls instead of detecting any random falls. Accordingly, we design and implement LT-Fall, a mmWave-based life-threatening fall detection and alarming system. LT-Fall detects and reports both fall and fall-like behaviors in the first stage and then identifies life-threatening falls by continuously monitoring the human status after fall in the second stage. We propose a joint spatio-temporal localization technique to detect and locate the micro-motions of the human, which solves the challenge of mmWave's insufficient spatial resolution when the human is static, i.e., lying on the ground. Extensive evaluation on 15 volunteers demonstrates that compared to the state-of-the-art work (92% precision and 94% recall), LT-Fall achieves zero false alarms as well as a precision of 100% and a recall of 98.8%.


  • Open Access

    WiMonitor: Continuous Long-Term Human Vitality Monitoring Using Commodity Wi-Fi Devices

    by Xiaopeng Niu, Shengjie Li, Yue Zhang, Zhaopeng Liu, Dan Wu, Rahul C. Shah, Cagri Tanriover, Hong Lu, Daqing Zhang

    For a large population of elderly who live alone, a continuous long-term daily monitoring system is critical and imminently needed to enhance the quality of their lives. Continuous monitoring of vitality information (i.e., which area the elder is staying in, the motion state and activity intensity of an elder) is essential for elderly care. In this paper, we use existing commodity Wi-Fi devices to design and implement a long-term device-free human daily vitality system, WiMonitor. Our system can continuously capture the target’s vitality information in a multi-room home environment without compromising the privacy of the target. In a continuous 22-day experiment, WiMonitor successfully captures the human vitality information accurately. We believe our system can provide valuable long-term monitoring data for both researchers and health care personnel.