Mushfiqur Rahman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mushfiqur Rahman has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Arupjyoti Bhuyan
Idaho National Laboratory
2 shared publications - Chau-Wai Wong
North Carolina State University
2 shared publications - Ismail Guvenc
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
2 shared publications - Alper Bozkurt
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27695, USA
1 shared publication - David L. Roberts
North Carolina State University, Raleigh, NC, USA
1 shared publication - Emily Summers
North Carolina State University, USA
1 shared publication
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
UAV-Based 3D Spectrum Sensing: Insights on Altitude, Bandwidth, Trajectory, and Effective Antenna Patterns on REM Reconstruction
Spectrum sensing and the generation of 3D Radio Environment Maps (REMs) are essential for enabling spectrum sharing within cognitive radio networks. While Uncrewed Aerial Vehicles (UAVs) offer high-mobility 3D sensing, REM accuracy is challenged by dynamic flight behaviors, where fluctuations in UAV speed and direction introduce measurement inconsistencies. Furthermore, the airframe itself impacts the onboard antenna’s radiation characteristics. In this paper, using real-world data, we systematically analyze how REM reconstruction accuracy is shaped by three key pillars: physical sensing parameters like altitude and bandwidth, environmental shadowing, and distortions caused by the UAV airframe. First, we benchmark diverse spatial prediction models, including simple Kriging (SK), ordinary Kriging (OK), trans-Gaussian Kriging, and Gaussian process regression (GPR). We demonstrate that while SK and its trans-Gaussian variant are highly accurate at extreme sample sparsity, OK improves as sample size increases, and GPR serves as the most stable overall baseline. Building on this, we propose a novel matrix completion (MC)-assisted GPR framework that enhances REM reconstruction in the presence of non-uniform spatial smoothness. The method operates by decomposing the REM into two distinct layers: a global smooth component and a highly varying local component. Our analysis based on real-world measurements reveals three key findings: 1) REM accuracy and shadowing variance follow a distinct tri-phasic trend as the UAV altitude increases; 2) REM accuracy significantly improves with increased spectrum bandwidth; and 3) antenna pattern calibration from in-field measurements significantly enhances REM accuracy by accounting for the effect of the UAV airframe.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
UAV-Based 3D Spectrum Sensing: Insights on Altitude, Bandwidth, Trajectory, and Effective Antenna Patterns on REM Reconstruction
Spectrum sensing and the generation of 3D Radio Environment Maps (REMs) are essential for enabling spectrum sharing within cognitive radio networks. While Uncrewed Aerial Vehicles (UAVs) offer high-mobility 3D sensing, REM accuracy is challenged by dynamic flight behaviors, where fluctuations in UAV speed and direction introduce measurement inconsistencies. Furthermore, the airframe itself impacts the onboard antenna’s radiation characteristics. In this paper, using real-world data, we systematically analyze how REM reconstruction accuracy is shaped by three key pillars: physical sensing parameters like altitude and bandwidth, environmental shadowing, and distortions caused by the UAV airframe. First, we benchmark diverse spatial prediction models, including simple Kriging (SK), ordinary Kriging (OK), trans-Gaussian Kriging, and Gaussian process regression (GPR). We demonstrate that while SK and its trans-Gaussian variant are highly accurate at extreme sample sparsity, OK improves as sample size increases, and GPR serves as the most stable overall baseline. Building on this, we propose a novel matrix completion (MC)-assisted GPR framework that enhances REM reconstruction in the presence of non-uniform spatial smoothness. The method operates by decomposing the REM into two distinct layers: a global smooth component and a highly varying local component. Our analysis based on real-world measurements reveals three key findings: 1) REM accuracy and shadowing variance follow a distinct tri-phasic trend as the UAV altitude increases; 2) REM accuracy significantly improves with increased spectrum bandwidth; and 3) antenna pattern calibration from in-field measurements significantly enhances REM accuracy by accounting for the effect of the UAV airframe.
- Open Access
- 5 December 2022
- Published by Association for Computing Machinery (ACM)
- p. 1-10
Contact-Free Simultaneous Sensing of Human Heart Rate and Canine Breathing Rate for Animal Assisted Interactions
Animal Assisted Interventions (AAIs) involve pleasant interactions between humans and animals and can potentially benefit both types of participants. Research in this field may help to uncover universal insights about cross-species bonding, dynamic affect detection, and the influence of environmental factors on dyadic interactions. However, experiments evaluating these outcomes are limited to methodologies that are qualitative, subjective, and cumbersome due to the ergonomic challenges related to attaching sensors to the body. Current approaches in AAIs also face challenges when translating beyond controlled clinical environments or research contexts. These also often neglect the measurements from the animal throughout the interaction. Here, we present our preliminary effort toward a contact-free approach to facilitate AAI assessment via the physiological sensing of humans and canines using consumer-grade cameras. This initial effort focuses on verifying the technological feasibility of remotely sensing the heart rate signal of the human subject and the breathing rate signal of the dog subject while they are interacting. Small amounts of motion such as patting and involuntary body shaking or movement can be tolerated with our custom designed vision-based algorithms. The experimental results show that the physiological measurements obtained by our algorithms were consistent with those provided by the standard reference devices. With further validation and expansion to other physiological parameters, the presented approach offers great promise for many scenarios from the AAI research space to veterinary, surgical, and clinical applications.
- 5 December 2022
- Published by Association for Computing Machinery (ACM)
- p. 1-10
Open AccessContact-Free Simultaneous Sensing of Human Heart Rate and Canine Breathing Rate for Animal Assisted Interactions
Animal Assisted Interventions (AAIs) involve pleasant interactions between humans and animals and can potentially benefit both types of participants. Research in this field may help to uncover universal insights about cross-species bonding, dynamic affect detection, and the influence of environmental factors on dyadic interactions. However, experiments evaluating these outcomes are limited to methodologies that are qualitative, subjective, and cumbersome due to the ergonomic challenges related to attaching sensors to the body. Current approaches in AAIs also face challenges when translating beyond controlled clinical environments or research contexts. These also often neglect the measurements from the animal throughout the interaction. Here, we present our preliminary effort toward a contact-free approach to facilitate AAI assessment via the physiological sensing of humans and canines using consumer-grade cameras. This initial effort focuses on verifying the technological feasibility of remotely sensing the heart rate signal of the human subject and the breathing rate signal of the dog subject while they are interacting. Small amounts of motion such as patting and involuntary body shaking or movement can be tolerated with our custom designed vision-based algorithms. The experimental results show that the physiological measurements obtained by our algorithms were consistent with those provided by the standard reference devices. With further validation and expansion to other physiological parameters, the presented approach offers great promise for many scenarios from the AAI research space to veterinary, surgical, and clinical applications.