Fenglin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fenglin Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anfu Zhou
Beijing University of Posts and Telecommunications
3 shared publications - Huadong Ma
Beijing University of Posts and Telecommunications
3 shared publications - Huaizhen Jia
China Jinmao Green Building Co.Ltd, Beijing, China
1 shared publication - Huanhuan Zhang
State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecommunications, Beijing, China
1 shared publication Jinbo Yan
Hunan University
1 shared publication- Langcheng Zhao
Beijing University of Posts and Telecommunications, Beijing, China
1 shared publication
Latest Publications
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 24 (2) , 627-641
mmTAA: A Contact-Less Thoracoabdominal Asynchrony Measurement System Based on mmWave Sensing
Thoracoabdominal Asynchrony (TAA) is a key metric in respiration monitoring, which characterizes the non-parallel periodical motion of human's rib cage (RC) and abdomen (AB) during each breath. Long-term measurement of TAA plays a significant role in respiration health tracking. Existing TAA measurement methods including Respiratory Inductive Plethysmography (RIP) and Optoelectronic Plethysmography (OEP) all intrusive to subjects and have certain requirements on operation conditions, which limit their usage to hospital scenario. To address this gap, we propose mmTAA, the first mmWave-based, non-intrusive TAA measurement system ready for ubiquitous usage in daily-life. In mmTAA, we design a Two-stage RC-AB centroid finding module, aiming to identify the most probable location of RC-AB centroid, which can best represent RC and AB in mmWave sensing scenario. Subsequently, we design TAANet, a novel Convolutional Neural Network (CNN)-based architecture with residual modules, tailored for TAA measurement. Meanwhile, in order to address the imbalance of continuous data, we add imbalance information equalizer including feature and label equalizer during network training. We implement mmTAA on a commonly used multi-antenna mmWave radar. We prototype, deploy and evaluate mmTAA on 25 subjects and 25.7h data in total. mmTAA achieves 4.01$^{\circ }$ MAE and 1.56$^{\circ }$ average error, close to OEP method.- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 24 (2) , 627-641
mmTAA: A Contact-Less Thoracoabdominal Asynchrony Measurement System Based on mmWave Sensing
Thoracoabdominal Asynchrony (TAA) is a key metric in respiration monitoring, which characterizes the non-parallel periodical motion of human's rib cage (RC) and abdomen (AB) during each breath. Long-term measurement of TAA plays a significant role in respiration health tracking. Existing TAA measurement methods including Respiratory Inductive Plethysmography (RIP) and Optoelectronic Plethysmography (OEP) all intrusive to subjects and have certain requirements on operation conditions, which limit their usage to hospital scenario. To address this gap, we propose mmTAA, the first mmWave-based, non-intrusive TAA measurement system ready for ubiquitous usage in daily-life. In mmTAA, we design a Two-stage RC-AB centroid finding module, aiming to identify the most probable location of RC-AB centroid, which can best represent RC and AB in mmWave sensing scenario. Subsequently, we design TAANet, a novel Convolutional Neural Network (CNN)-based architecture with residual modules, tailored for TAA measurement. Meanwhile, in order to address the imbalance of continuous data, we add imbalance information equalizer including feature and label equalizer during network training. We implement mmTAA on a commonly used multi-antenna mmWave radar. We prototype, deploy and evaluate mmTAA on 25 subjects and 25.7h data in total. mmTAA achieves 4.01$^{\circ }$ MAE and 1.56$^{\circ }$ average error, close to OEP method.- Open Access
- 5 July 2024
- Published by Association for Computing Machinery (ACM)
- p. 18-22
mmCare: A Nursing Care Activity Monitoring System via mmWave Sensing
With the advent of an aging society, an increasing number of patients require appropriate care. Simultaneously, there is currently a lack of effective solutions for monitoring nursing behaviors. In order to address this issue, we propose mmCare, a nursing care activity detection system based on mmWave sensing, capable of achieving comparatively accurate and effective monitoring while preserving privacy. Through standardization processing of point cloud information into point cloud pictures and extraction of spatio-temporal features, mmCare ultimately identifies 7 categories of nursing actions. Through practical deployment and evaluation of real-world datasets, mmCare achieves an accuracy rate of 93.52% on the individual test dataset.
- 5 July 2024
- Published by Association for Computing Machinery (ACM)
- p. 18-22
Open AccessmmCare: A Nursing Care Activity Monitoring System via mmWave Sensing
With the advent of an aging society, an increasing number of patients require appropriate care. Simultaneously, there is currently a lack of effective solutions for monitoring nursing behaviors. In order to address this issue, we propose mmCare, a nursing care activity detection system based on mmWave sensing, capable of achieving comparatively accurate and effective monitoring while preserving privacy. Through standardization processing of point cloud information into point cloud pictures and extraction of spatio-temporal features, mmCare ultimately identifies 7 categories of nursing actions. Through practical deployment and evaluation of real-world datasets, mmCare achieves an accuracy rate of 93.52% on the individual test dataset.
- Open Access
- 8 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (24) , 16426
Grey Multivariable Prediction Model of Energy Consumption with Different Fractional Orders
The scientific prediction of energy consumption plays an essential role in grasping trends in energy consumption and optimizing energy structures. Energy consumption will be affected by many factors. In this paper, in order to improve the accuracy of the prediction model, the grey correlation analysis method is used to analyze the relevant factors. First, the factor with the largest correlation degree is selected, and then a new grey multivariable convolution prediction model with dual orders is established. Different fractional orders are used to accumulate the target data sequence and the influencing-factor data sequence, and the model is optimized by particle swarm optimization algorithm. The model is used to fit and test the energy consumption of Shanghai, Guizhou and Shandong provinces in China from 2011 to 2020 compared with other multivariable grey prediction models. Experimental results with the MAPE and RMSPE measurements show that our improved model is reasonable and effective in energy consumption prediction. At the same time, the model is applied to forecast the energy consumption of the three regions from 2021 to 2025, providing reliable information for future energy distribution.
- 8 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (24) , 16426
Open AccessGrey Multivariable Prediction Model of Energy Consumption with Different Fractional Orders
The scientific prediction of energy consumption plays an essential role in grasping trends in energy consumption and optimizing energy structures. Energy consumption will be affected by many factors. In this paper, in order to improve the accuracy of the prediction model, the grey correlation analysis method is used to analyze the relevant factors. First, the factor with the largest correlation degree is selected, and then a new grey multivariable convolution prediction model with dual orders is established. Different fractional orders are used to accumulate the target data sequence and the influencing-factor data sequence, and the model is optimized by particle swarm optimization algorithm. The model is used to fit and test the energy consumption of Shanghai, Guizhou and Shandong provinces in China from 2011 to 2020 compared with other multivariable grey prediction models. Experimental results with the MAPE and RMSPE measurements show that our improved model is reasonable and effective in energy consumption prediction. At the same time, the model is applied to forecast the energy consumption of the three regions from 2021 to 2025, providing reliable information for future energy distribution.
- 7 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (6) , 4830-4844
Robust Respiratory Rate Monitoring Using Smartwatch Photoplethysmography
Respiratory rate is of great value in health care, especially when it can be continuously monitored using wearable devices in daily life. Recent works employ Photoplethysmography (PPG) on smartwatch for continuous respiration monitoring, based on a certain medical discovery called Respiratory Sinus Arrhythmia (RSA), which describes the relationship between respiratory and heart rate. However, we find that these works fall short of robustness. In particular, the respiratory estimation accuracy drops significantly when people breathe faster (e.g., after sports). We further identify the root reason that the RSA gradually weakens as the respiratory rate increases. In this paper, we propose BreathAnalyzer, which can estimate respiratory rate accurately even at high respiratory rates. To achieve this, BreathAnalyzer boosts the weakened RSA and also handles the motion artifacts, by integrating features from multiple domains, i.e., frequency, time and non-linear Poincare domain, instead of using the single spectrum or raw signal in previous studies. Moreover, BreathAnalyzer custom-designs a tree-based learning model, which fits multi-domain features, while considering limitations of smartwatch. We implement BreathAnalyzer prototype on COTS smartwatch, and extensive evaluation demonstrates that BreathAnalyzer outperforms the state-of-the-art approaches, with accuracy improvement by 35.37% ∼ 80.42% across a variety of practical scenarios including high respiratory rates.
- 7 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (6) , 4830-4844
Robust Respiratory Rate Monitoring Using Smartwatch Photoplethysmography
Respiratory rate is of great value in health care, especially when it can be continuously monitored using wearable devices in daily life. Recent works employ Photoplethysmography (PPG) on smartwatch for continuous respiration monitoring, based on a certain medical discovery called Respiratory Sinus Arrhythmia (RSA), which describes the relationship between respiratory and heart rate. However, we find that these works fall short of robustness. In particular, the respiratory estimation accuracy drops significantly when people breathe faster (e.g., after sports). We further identify the root reason that the RSA gradually weakens as the respiratory rate increases. In this paper, we propose BreathAnalyzer, which can estimate respiratory rate accurately even at high respiratory rates. To achieve this, BreathAnalyzer boosts the weakened RSA and also handles the motion artifacts, by integrating features from multiple domains, i.e., frequency, time and non-linear Poincare domain, instead of using the single spectrum or raw signal in previous studies. Moreover, BreathAnalyzer custom-designs a tree-based learning model, which fits multi-domain features, while considering limitations of smartwatch. We implement BreathAnalyzer prototype on COTS smartwatch, and extensive evaluation demonstrates that BreathAnalyzer outperforms the state-of-the-art approaches, with accuracy improvement by 35.37% ∼ 80.42% across a variety of practical scenarios including high respiratory rates.
- 21 September 2019
- Published by Springer Nature
- p. 3-10
Quality Index Evaluation Model Based on Index Screening Model
- 21 September 2019
- Published by Springer Nature
- p. 3-10
Quality Index Evaluation Model Based on Index Screening Model