Alex J. Allphin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex J. Allphin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Cristian T. Badea
Duke University Medical Center
6 shared publications Rohan Nadkarni
Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA, Durham, North Carolina, 277075164, UNITED STATES
3 shared publicationsD P Clark
Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Box 3302, Durham, North Carolina, 27710, UNITED STATES
2 shared publicationsDarin P Clark
Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA, Durham, North Carolina, 27710, UNITED STATES
2 shared publicationsAlexandra Badea
Affiliation Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Durham, North Carolina, United States of America
1 shared publication- Alexandra Badea
Duke Univ Medical Center
1 shared publication
Latest Publications
- 7 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145002
Photon-counting micro-CT scanner for deep learning-enabled small animal perfusion imaging
Objective. In this work, we introduce a benchtop, turn-table photon-counting (PC) micro-computed tomography (CT) scanner and highlight its application for dynamic small animal perfusion imaging. Approach. Built on recently published hardware, the system now features a CdTe-based PC detector. We validated its static spectral PC micro-CT imaging using conventional phantoms and assessed dynamic performance with a custom flow-configurable dual-compartment perfusion phantom. The phantom was scanned under varied flow conditions during injections of a low molecular weight iodinated contrast agent. In vivo mouse studies with identical injection settings demonstrated potential applications. A pretrained denoising convolutional neural network (CNN) processed large multi-energy, temporal datasets (20 timepoints ×4 energies ×3 spatial dimensions), reconstructed via weighted filtered back projection. A separate CNN, trained on simulated data, performed gamma variate-based 2D perfusion mapping, evaluated qualitatively in phantom and in vivo tests. Main Results. Full five-dimensional reconstructions were denoised using a CNN in ∼3% of the time of iterative reconstruction, reducing noise in water at the highest energy threshold from 1206 HU to 86 HU. Decomposed iodine maps, which improved contrast to noise ratio from 16.4 (in the lowest energy CT images) to 29.4 (in the iodine maps), were used for perfusion analysis. The perfusion CNN outperformed pixelwise gamma variate fitting by ∼33%, with a test set error of 0.04 vs. 0.06 in blood flow index (BFI) maps, and quantified linear BFI changes in the phantom with a coefficient of determination of 0.98. Significance. This work underscores the PC micro-CT scanner’s utility for high-throughput small animal perfusion imaging, leveraging spectral PC micro-CT and iodine decomposition. It provides a versatile platform for preclinical vascular research and advanced, time-resolved studies of disease models and therapeutic interventions.
- 7 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145002
Photon-counting micro-CT scanner for deep learning-enabled small animal perfusion imaging
Objective. In this work, we introduce a benchtop, turn-table photon-counting (PC) micro-computed tomography (CT) scanner and highlight its application for dynamic small animal perfusion imaging. Approach. Built on recently published hardware, the system now features a CdTe-based PC detector. We validated its static spectral PC micro-CT imaging using conventional phantoms and assessed dynamic performance with a custom flow-configurable dual-compartment perfusion phantom. The phantom was scanned under varied flow conditions during injections of a low molecular weight iodinated contrast agent. In vivo mouse studies with identical injection settings demonstrated potential applications. A pretrained denoising convolutional neural network (CNN) processed large multi-energy, temporal datasets (20 timepoints ×4 energies ×3 spatial dimensions), reconstructed via weighted filtered back projection. A separate CNN, trained on simulated data, performed gamma variate-based 2D perfusion mapping, evaluated qualitatively in phantom and in vivo tests. Main Results. Full five-dimensional reconstructions were denoised using a CNN in ∼3% of the time of iterative reconstruction, reducing noise in water at the highest energy threshold from 1206 HU to 86 HU. Decomposed iodine maps, which improved contrast to noise ratio from 16.4 (in the lowest energy CT images) to 29.4 (in the iodine maps), were used for perfusion analysis. The perfusion CNN outperformed pixelwise gamma variate fitting by ∼33%, with a test set error of 0.04 vs. 0.06 in blood flow index (BFI) maps, and quantified linear BFI changes in the phantom with a coefficient of determination of 0.98. Significance. This work underscores the PC micro-CT scanner’s utility for high-throughput small animal perfusion imaging, leveraging spectral PC micro-CT and iodine decomposition. It provides a versatile platform for preclinical vascular research and advanced, time-resolved studies of disease models and therapeutic interventions.
- Open Access
- 10 April 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (4) , e0320892
Assessing the cardioprotective effects of exercise in APOE mouse models using deep learning and photon-counting micro-CT
Background: The allelic variations of the apolipoprotein E (APOE) gene play a critical role in regulating lipid metabolism and significantly impact cardiovascular disease risk (CVD). This study aimed to evaluate the impact of exercise on cardiac structure and function in mouse models expressing different APOE genotypes using photon-counting computed tomography (PCCT) and deep learning-based segmentation. Methods: A total of 140 mice were grouped based on APOE genotype (APOE2, APOE3, APOE4), sex, and exercise regimen. All mice were maintained on a controlled diet to isolate the effects of exercise. Low dose cardiac photon counting micro-CT imaging with intrinsic gating was performed using a custom-built micro-PCCT system and data was reconstructed with an iterative algorithm incorporating both temporal and spectral dimensions. A liposomal-iodine nanoparticle contrast agent was intravenously administered to uniformly opacify cardiovascular structures. Cardiac structures were segmented using a 3D U-Net deep learning model that was trained and validated on manually labeled data. Statistical analyses, including ANOVA, post-hoc analysis, and stratified group comparisons, were used to assess the effects of genotype, sex, and exercise on key cardiac metrics, including ejection fraction and cardiac index. Results: The PCCT imaging pipeline provided high-resolution images with enhanced contrast between blood compartment and myocardium allowing for precise segmentation of cardiac features. Deep learning-based segmentation achieved high accuracy with an average Dice coefficient of 0.85. Exercise significantly improved cardiac performance, with ejection fraction increasing by up to 18% and cardiac index by 46% in exercised males, who generally benefited more from exercise. Females, particularly those with the APOE4 genotype, also showed improvements, with a 31% higher ejection fraction in exercised versus non-exercised mice. Stratified analyses confirmed that both sexes benefited from exercise, with males showing larger effect sizes. APOE3 and APOE4 genotypes derived the greatest benefit, while APOE2 mice showed no significant improvement. Conclusions: This study demonstrates the utility of PCCT combined with deep learning segmentation in assessing the cardioprotective effects of exercise in APOE mouse models. These findings highlight the importance of genotype-specific approaches in understanding and potentially mitigating the impact of CVD through lifestyle interventions such as exercise.
- 10 April 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (4) , e0320892
Open AccessAssessing the cardioprotective effects of exercise in APOE mouse models using deep learning and photon-counting micro-CT
Background: The allelic variations of the apolipoprotein E (APOE) gene play a critical role in regulating lipid metabolism and significantly impact cardiovascular disease risk (CVD). This study aimed to evaluate the impact of exercise on cardiac structure and function in mouse models expressing different APOE genotypes using photon-counting computed tomography (PCCT) and deep learning-based segmentation. Methods: A total of 140 mice were grouped based on APOE genotype (APOE2, APOE3, APOE4), sex, and exercise regimen. All mice were maintained on a controlled diet to isolate the effects of exercise. Low dose cardiac photon counting micro-CT imaging with intrinsic gating was performed using a custom-built micro-PCCT system and data was reconstructed with an iterative algorithm incorporating both temporal and spectral dimensions. A liposomal-iodine nanoparticle contrast agent was intravenously administered to uniformly opacify cardiovascular structures. Cardiac structures were segmented using a 3D U-Net deep learning model that was trained and validated on manually labeled data. Statistical analyses, including ANOVA, post-hoc analysis, and stratified group comparisons, were used to assess the effects of genotype, sex, and exercise on key cardiac metrics, including ejection fraction and cardiac index. Results: The PCCT imaging pipeline provided high-resolution images with enhanced contrast between blood compartment and myocardium allowing for precise segmentation of cardiac features. Deep learning-based segmentation achieved high accuracy with an average Dice coefficient of 0.85. Exercise significantly improved cardiac performance, with ejection fraction increasing by up to 18% and cardiac index by 46% in exercised males, who generally benefited more from exercise. Females, particularly those with the APOE4 genotype, also showed improvements, with a 31% higher ejection fraction in exercised versus non-exercised mice. Stratified analyses confirmed that both sexes benefited from exercise, with males showing larger effect sizes. APOE3 and APOE4 genotypes derived the greatest benefit, while APOE2 mice showed no significant improvement. Conclusions: This study demonstrates the utility of PCCT combined with deep learning segmentation in assessing the cardioprotective effects of exercise in APOE mouse models. These findings highlight the importance of genotype-specific approaches in understanding and potentially mitigating the impact of CVD through lifestyle interventions such as exercise.
- 7 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (20) , 205010
Investigating deep learning strategies for fast denoising of 5D cardiac photon-counting micro-CT images
Objective. Photon-counting detectors for CT imaging use energy thresholds to simultaneously acquire projections at multiple energies, making them suitable for spectral imaging and material decomposition. Unfortunately, setting multiple energy thresholds results in noisy analytical reconstructions due to low photon counts in high-energy bins. Iterative reconstruction provides high quality photon-counting CT (PCCT) images but requires enormous computation time for 5D (3D + energy + time) in vivo cardiac imaging. Approach. We recently introduced UnetU, a deep learning (DL) approach that accurately denoises axial slices from 4D (3D + energy) PCCT reconstructions at various acquisition settings. In this study, we explore UnetU configurations for 5D cardiac PCCT denoising, focusing on singular value decomposition (SVD) modifications along the energy and time dimensions and alternate network architectures such as 3D U-net, FastDVDNet, and Swin Transformer UNet. We compare our networks to multi-energy non-local means (ME NLM), an established PCCT denoising algorithm. Main results. Our evaluation, using real mouse data and the digital MOBY phantom, revealed that all DL methods were more than 16 times faster than iterative reconstruction. DL denoising with SVD along the energy dimension was most effective, consistently providing low root mean square error and spatio-temporal reduced reference entropic difference, alongside strong qualitative agreement with iterative reconstruction. This superiority was attributed to lower effective rank along the energy dimension than the time dimension in 5D cardiac PCCT reconstructions. ME NLM sometimes outperformed DL with time SVD or time and energy SVD, but lagged behind iterative reconstruction and DL with energy SVD. Among alternate DL architectures with energy SVD, none consistently outperformed UnetU Energy (2D). Significance. Our study establishes UnetU Energy as an accurate and efficient method for 5D cardiac PCCT denoising, offering a 32-fold speed increase from iterative reconstruction. This advancement sets a new benchmark for DL applications in cardiovascular imaging.
- 7 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (20) , 205010
Investigating deep learning strategies for fast denoising of 5D cardiac photon-counting micro-CT images
Objective. Photon-counting detectors for CT imaging use energy thresholds to simultaneously acquire projections at multiple energies, making them suitable for spectral imaging and material decomposition. Unfortunately, setting multiple energy thresholds results in noisy analytical reconstructions due to low photon counts in high-energy bins. Iterative reconstruction provides high quality photon-counting CT (PCCT) images but requires enormous computation time for 5D (3D + energy + time) in vivo cardiac imaging. Approach. We recently introduced UnetU, a deep learning (DL) approach that accurately denoises axial slices from 4D (3D + energy) PCCT reconstructions at various acquisition settings. In this study, we explore UnetU configurations for 5D cardiac PCCT denoising, focusing on singular value decomposition (SVD) modifications along the energy and time dimensions and alternate network architectures such as 3D U-net, FastDVDNet, and Swin Transformer UNet. We compare our networks to multi-energy non-local means (ME NLM), an established PCCT denoising algorithm. Main results. Our evaluation, using real mouse data and the digital MOBY phantom, revealed that all DL methods were more than 16 times faster than iterative reconstruction. DL denoising with SVD along the energy dimension was most effective, consistently providing low root mean square error and spatio-temporal reduced reference entropic difference, alongside strong qualitative agreement with iterative reconstruction. This superiority was attributed to lower effective rank along the energy dimension than the time dimension in 5D cardiac PCCT reconstructions. ME NLM sometimes outperformed DL with time SVD or time and energy SVD, but lagged behind iterative reconstruction and DL with energy SVD. Among alternate DL architectures with energy SVD, none consistently outperformed UnetU Energy (2D). Significance. Our study establishes UnetU Energy as an accurate and efficient method for 5D cardiac PCCT denoising, offering a 32-fold speed increase from iterative reconstruction. This advancement sets a new benchmark for DL applications in cardiovascular imaging.
- 23 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175012
Turn-table micro-CT scanner for dynamic perfusion imaging in mice: design, implementation, and evaluation
Objective. This study introduces a novel desktop micro-CT scanner designed for dynamic perfusion imaging in mice, aimed at enhancing preclinical imaging capabilities with high resolution and low radiation doses. Approach. The micro-CT system features a custom-built rotating table capable of both circular and helical scans, enabled by a small-bore slip ring for continuous rotation. Images were reconstructed with a temporal resolution of 3.125 s and an isotropic voxel size of 65 µm, with potential for higher resolution scanning. The system’s static performance was validated using standard quality assurance phantoms. Dynamic performance was assessed with a custom 3D-bioprinted tissue-mimetic phantom simulating single-compartment vascular flow. Flow measurements ranged from 1.5 1 to 9 ml min−1, with perfusion metrics such as time-to-peak, mean transit time, and blood flow index calculated. In vivo experiments involved mice with different genetic risk factors for Alzheimer’s and cardiovascular diseases to showcase the system’s capabilities for perfusion imaging. Main Results. The static performance validation confirmed that the system meets standard quality metrics, such as spatial resolution and uniformity. The dynamic evaluation with the 3D-bioprinted phantom demonstrated linearity in hemodynamic flow measurements and effective quantification of perfusion metrics. In vivo experiments highlighted the system’s potential to capture detailed perfusion maps of the brain, lungs, and kidneys. The observed differences in perfusion characteristics between genotypic mice illustrated the system’s capability to detect physiological variations, though the small sample size precludes definitive conclusions. Significance. The turn-table micro-CT system represents a significant advancement in preclinical imaging, providing high-resolution, low-dose dynamic imaging for a range of biological and medical research applications. Future work will focus on improving temporal resolution, expanding spectral capabilities, and integrating deep learning techniques for enhanced image reconstruction and analysis.
- 23 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175012
Turn-table micro-CT scanner for dynamic perfusion imaging in mice: design, implementation, and evaluation
Objective. This study introduces a novel desktop micro-CT scanner designed for dynamic perfusion imaging in mice, aimed at enhancing preclinical imaging capabilities with high resolution and low radiation doses. Approach. The micro-CT system features a custom-built rotating table capable of both circular and helical scans, enabled by a small-bore slip ring for continuous rotation. Images were reconstructed with a temporal resolution of 3.125 s and an isotropic voxel size of 65 µm, with potential for higher resolution scanning. The system’s static performance was validated using standard quality assurance phantoms. Dynamic performance was assessed with a custom 3D-bioprinted tissue-mimetic phantom simulating single-compartment vascular flow. Flow measurements ranged from 1.5 1 to 9 ml min−1, with perfusion metrics such as time-to-peak, mean transit time, and blood flow index calculated. In vivo experiments involved mice with different genetic risk factors for Alzheimer’s and cardiovascular diseases to showcase the system’s capabilities for perfusion imaging. Main Results. The static performance validation confirmed that the system meets standard quality metrics, such as spatial resolution and uniformity. The dynamic evaluation with the 3D-bioprinted phantom demonstrated linearity in hemodynamic flow measurements and effective quantification of perfusion metrics. In vivo experiments highlighted the system’s potential to capture detailed perfusion maps of the brain, lungs, and kidneys. The observed differences in perfusion characteristics between genotypic mice illustrated the system’s capability to detect physiological variations, though the small sample size precludes definitive conclusions. Significance. The turn-table micro-CT system represents a significant advancement in preclinical imaging, providing high-resolution, low-dose dynamic imaging for a range of biological and medical research applications. Future work will focus on improving temporal resolution, expanding spectral capabilities, and integrating deep learning techniques for enhanced image reconstruction and analysis.
- Open Access
- 5 October 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (10) , e0291733
Advanced photon counting CT imaging pipeline for cardiac phenotyping of apolipoprotein E mouse models
Background: Cardiovascular disease (CVD) is associated with the apolipoprotein E (APOE) gene and lipid metabolism. This study aimed to develop an imaging-based pipeline to comprehensively assess cardiac structure and function in mouse models expressing different APOE genotypes using photon-counting computed tomography (PCCT). Methods: 123 mice grouped based on APOE genotype (APOE2, APOE3, APOE4, APOE knockout (KO)), gender, human NOS2 factor, and diet (control or high fat) were used in this study. The pipeline included PCCT imaging on a custom-built system with contrast-enhanced in vivo imaging and intrinsic cardiac gating, spectral and temporal iterative reconstruction, spectral decomposition, and deep learning cardiac segmentation. Statistical analysis evaluated genotype, diet, sex, and body weight effects on cardiac measurements. Results: Our results showed that PCCT offered high quality imaging with reduced noise. Material decomposition enabled separation of calcified plaques from iodine enhanced blood in APOE KO mice. Deep learning-based segmentation showed good performance with Dice scores of 0.91 for CT-based segmentation and 0.89 for iodine map-based segmentation. Genotype-specific differences were observed in left ventricular volumes, heart rate, stroke volume, ejection fraction, and cardiac index. Statistically significant differences were found between control and high fat diets for APOE2 and APOE4 genotypes in heart rate and stroke volume. Sex and weight were also significant predictors of cardiac measurements. The inclusion of the human NOS2 gene modulated these effects. Conclusions: This study demonstrates the potential of PCCT in assessing cardiac structure and function in mouse models of CVD which can help in understanding the interplay between genetic factors, diet, and cardiovascular health.
- 5 October 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (10) , e0291733
Open AccessAdvanced photon counting CT imaging pipeline for cardiac phenotyping of apolipoprotein E mouse models
Background: Cardiovascular disease (CVD) is associated with the apolipoprotein E (APOE) gene and lipid metabolism. This study aimed to develop an imaging-based pipeline to comprehensively assess cardiac structure and function in mouse models expressing different APOE genotypes using photon-counting computed tomography (PCCT). Methods: 123 mice grouped based on APOE genotype (APOE2, APOE3, APOE4, APOE knockout (KO)), gender, human NOS2 factor, and diet (control or high fat) were used in this study. The pipeline included PCCT imaging on a custom-built system with contrast-enhanced in vivo imaging and intrinsic cardiac gating, spectral and temporal iterative reconstruction, spectral decomposition, and deep learning cardiac segmentation. Statistical analysis evaluated genotype, diet, sex, and body weight effects on cardiac measurements. Results: Our results showed that PCCT offered high quality imaging with reduced noise. Material decomposition enabled separation of calcified plaques from iodine enhanced blood in APOE KO mice. Deep learning-based segmentation showed good performance with Dice scores of 0.91 for CT-based segmentation and 0.89 for iodine map-based segmentation. Genotype-specific differences were observed in left ventricular volumes, heart rate, stroke volume, ejection fraction, and cardiac index. Statistically significant differences were found between control and high fat diets for APOE2 and APOE4 genotypes in heart rate and stroke volume. Sex and weight were also significant predictors of cardiac measurements. The inclusion of the human NOS2 gene modulated these effects. Conclusions: This study demonstrates the potential of PCCT in assessing cardiac structure and function in mouse models of CVD which can help in understanding the interplay between genetic factors, diet, and cardiovascular health.
- 12 April 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (8) , 085023
Micro-CT imaging of multiple K-edge elements using GaAs and CdTe photon counting detectors
Objective. To evaluate the performance of two photon-counting (PC) detectors based on different detector materials, gallium arsenide (GaAs) and cadmium telluride (CdTe), for PC micro-CT imaging of phantoms with multiple contrast materials. Another objective is to determine if combining these two detectors in the same micro-CT system can offer higher spectral performance and significant artifact reduction compared to a single detector system. Approach . We have constructed a dual-detector, micro-CT system equipped with two PCDs based on different detector materials: gallium arsenide (GaAs) and cadmium telluride (CdTe). We demonstrate the performance of these detectors for PC micro-CT imaging of phantoms with up to 5 contrast materials with K-edges spread across the x-ray spectrum ranging from iodine with a K-edge at 33.2 keV to bismuth with a K-edge at 90.5 keV. We also demonstrate the use of our system to image a mouse prepared with both iodine and bismuth contrast agents to target different biological systems. Main results. When using the same dose and scan parameters, GaAs shows increased low energy (Significance. More accurate PC micro-CT using a GaAs PCD alone or in combination with a CdTe PCD could serve for developing new contrast agents such as nanoparticles that show promise in the developing field of theranostics (therapy and diagnostics).
- 12 April 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (8) , 085023
Micro-CT imaging of multiple K-edge elements using GaAs and CdTe photon counting detectors
Objective. To evaluate the performance of two photon-counting (PC) detectors based on different detector materials, gallium arsenide (GaAs) and cadmium telluride (CdTe), for PC micro-CT imaging of phantoms with multiple contrast materials. Another objective is to determine if combining these two detectors in the same micro-CT system can offer higher spectral performance and significant artifact reduction compared to a single detector system. Approach . We have constructed a dual-detector, micro-CT system equipped with two PCDs based on different detector materials: gallium arsenide (GaAs) and cadmium telluride (CdTe). We demonstrate the performance of these detectors for PC micro-CT imaging of phantoms with up to 5 contrast materials with K-edges spread across the x-ray spectrum ranging from iodine with a K-edge at 33.2 keV to bismuth with a K-edge at 90.5 keV. We also demonstrate the use of our system to image a mouse prepared with both iodine and bismuth contrast agents to target different biological systems. Main results. When using the same dose and scan parameters, GaAs shows increased low energy (Significance. More accurate PC micro-CT using a GaAs PCD alone or in combination with a CdTe PCD could serve for developing new contrast agents such as nanoparticles that show promise in the developing field of theranostics (therapy and diagnostics).