Hiroki Minoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroki Minoda has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Toshiki Shimizu
Department of Applied Physics and Chemical Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo 184-8588, Japan
5 shared publicationsHirofumi Iijima
JEOL Ltd, 3-1-2 Musashino, Akishima, Tokyo 196-8558, Japan
3 shared publications- Kazuyuki Yagi
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University
3 shared publications Naoki Yamamoto
Tokyo Institute of Technology
3 shared publications- Toshiki Shimizu
Department of Applied Physics, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo 184-8588, Japan; Department of Applied Physics and Chemical Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo 184-8588, Japan
3 shared publications - Yasumasa Tanishiro
Tokyo Institute of Technology,Japan
3 shared publications
Latest Publications
- 21 August 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (33) , 19231-19242
Evolution of the formation of AgBiS 2 colloidal nanocrystals for optoelectronic devices
Precise synthesis control and structural determination of AgBiS 2 NC formation allow the demonstration of high-performance photodetector devices.
- 21 August 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (33) , 19231-19242
Evolution of the formation of AgBiS 2 colloidal nanocrystals for optoelectronic devices
Precise synthesis control and structural determination of AgBiS 2 NC formation allow the demonstration of high-performance photodetector devices.
- Open Access
- 1 January 2025
- Published by ScienceOpen
- p. e338
Direct Observation of Crystal Growth Process of NaCl Nanocrystals in Aqueous Environment Using In Situ Liquid Cell Transmission Electron Microscopy
Crystal growth is one of the most fundamental phenomena in nature. Crystal structure determines most of the properties of materials, playing a key role in industry. Crystalline materials are closely involved in the development of medicines or devices and the production of foods such as salt. Since they are essential to our daily lives, many studies were attempted to understand the mechanism of crystal growth. Thanks to the development of microscopic methods, we can now directly observe specimens at the molecular level. Nevertheless, direct observations of crystal growth process with detailed information of atomic-scale lattice and cluster additions are still rare [ 1]. In particular, sodium chloride (NaCl) is a typical example of a crystalline material and is an indispensable mineral for humankind, but the reports of the nanoscale visualization of NaCl crystal growth are limited only in special environments such as in carbon nanotubes or in acetone. [ 2, 3]. Generally, the crystal growth process of NaCl takes place in water and thus involves direct observation of NaCl in an aqueous environment to fully understand the mechanism. Under these circumstances, we have developed a unique liquid cell composed of amorphous carbon films supported by the holey plastic film spacer that enabled in situ observation in an aqueous environment with a general TEM [ 4]. While the impermeability of amorphous carbon films enabled the encapsulation of small water molecules without leaking to surrounding vacuum environment of TEM chamber, the electron conductivity and chemical stability of the amorphous carbon films reduced the film charging and water radiolysis effects.
- 1 January 2025
- Published by ScienceOpen
- p. e338
Open AccessDirect Observation of Crystal Growth Process of NaCl Nanocrystals in Aqueous Environment Using In Situ Liquid Cell Transmission Electron Microscopy
Crystal growth is one of the most fundamental phenomena in nature. Crystal structure determines most of the properties of materials, playing a key role in industry. Crystalline materials are closely involved in the development of medicines or devices and the production of foods such as salt. Since they are essential to our daily lives, many studies were attempted to understand the mechanism of crystal growth. Thanks to the development of microscopic methods, we can now directly observe specimens at the molecular level. Nevertheless, direct observations of crystal growth process with detailed information of atomic-scale lattice and cluster additions are still rare [ 1]. In particular, sodium chloride (NaCl) is a typical example of a crystalline material and is an indispensable mineral for humankind, but the reports of the nanoscale visualization of NaCl crystal growth are limited only in special environments such as in carbon nanotubes or in acetone. [ 2, 3]. Generally, the crystal growth process of NaCl takes place in water and thus involves direct observation of NaCl in an aqueous environment to fully understand the mechanism. Under these circumstances, we have developed a unique liquid cell composed of amorphous carbon films supported by the holey plastic film spacer that enabled in situ observation in an aqueous environment with a general TEM [ 4]. While the impermeability of amorphous carbon films enabled the encapsulation of small water molecules without leaking to surrounding vacuum environment of TEM chamber, the electron conductivity and chemical stability of the amorphous carbon films reduced the film charging and water radiolysis effects.
- 25 November 2024
- Published by Elsevier in Ultramicroscopy
- Vol. 268, 114082
Effect of the surrounding environment on electron beam irradiation damage of enhanced green fluorescent protein
- 25 November 2024
- Published by Elsevier in Ultramicroscopy
- Vol. 268, 114082
Effect of the surrounding environment on electron beam irradiation damage of enhanced green fluorescent protein
- 29 March 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 73 (5) , 414-421
Application of Hilbert-differential phase contrast to scanning transmission electron microscopy
We report a novel class of scanning transmission electron microscopy with Hilbert-differential phase contrast (HDP-STEM) that displays nanostructures of thin samples in a topographical manner. A semicircular π-phase plate (PP) was used as an optical device for manipulating electron waves in HDP-STEM. This is the different design from the Zernike PP used in our previous phase plate STEM (P-STEM), but both must be placed in the front focal plane of the condenser lens. HDP-STEM images of multiwalled carbon nanotubes showed higher contrast than those obtained by conventional bright-field STEM. As the PP of the HDP-STEM is nonsymmetrical, several different images were obtained by changing the detection conditions. A two-dimensional electron detector was also used to remove the scattering contrast component in the same way as with the Zernike PP and obtain an image containing only (differential) phase contrast.
- 29 March 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 73 (5) , 414-421
Application of Hilbert-differential phase contrast to scanning transmission electron microscopy
We report a novel class of scanning transmission electron microscopy with Hilbert-differential phase contrast (HDP-STEM) that displays nanostructures of thin samples in a topographical manner. A semicircular π-phase plate (PP) was used as an optical device for manipulating electron waves in HDP-STEM. This is the different design from the Zernike PP used in our previous phase plate STEM (P-STEM), but both must be placed in the front focal plane of the condenser lens. HDP-STEM images of multiwalled carbon nanotubes showed higher contrast than those obtained by conventional bright-field STEM. As the PP of the HDP-STEM is nonsymmetrical, several different images were obtained by changing the detection conditions. A two-dimensional electron detector was also used to remove the scattering contrast component in the same way as with the Zernike PP and obtain an image containing only (differential) phase contrast.
- 8 September 2023
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 6 (18) , 9363-9370
Visualization of Tens of Nanometers Spaced Donor: Acceptor Bulk Heterojunctions across Submicrometer-Square Cross Sections of Organic Photovoltaic Cells
- 8 September 2023
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 6 (18) , 9363-9370
Visualization of Tens of Nanometers Spaced Donor: Acceptor Bulk Heterojunctions across Submicrometer-Square Cross Sections of Organic Photovoltaic Cells
- 30 March 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 249, 113729
First step toward complex observations by 4D-STEM with phase plate
- 30 March 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 249, 113729
First step toward complex observations by 4D-STEM with phase plate
- 23 February 2022
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 71 (2) , 117-123
Toward complex observation in electron microscopy using two-dimensional electron detector coupled with phase plate STEM
A two-dimensional (2D) detector was used to construct phase plate STEM (P-STEM) images. Phase-contrast can be enhanced by the electron intensity inside the hole region of a thin film phase plate. The electron intensity outside the hole region also provides a dark image contrast, which is inconsistent with the weak phase object approximation. We consider that both images have scattering effects that provide a dark contrast. Therefore, scattering contrast was derived by summing these two images, and scattering effects were subtracted from each image to display negative and positive phase contrast. The resultant images are consistent with the weak phase object approximation. These results propose separating scattering (electron amplitude) and phase-contrast (electron phase) using P-STEM, along with a two-dimensional electron detector.
- 23 February 2022
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 71 (2) , 117-123
Toward complex observation in electron microscopy using two-dimensional electron detector coupled with phase plate STEM
A two-dimensional (2D) detector was used to construct phase plate STEM (P-STEM) images. Phase-contrast can be enhanced by the electron intensity inside the hole region of a thin film phase plate. The electron intensity outside the hole region also provides a dark image contrast, which is inconsistent with the weak phase object approximation. We consider that both images have scattering effects that provide a dark contrast. Therefore, scattering contrast was derived by summing these two images, and scattering effects were subtracted from each image to display negative and positive phase contrast. The resultant images are consistent with the weak phase object approximation. These results propose separating scattering (electron amplitude) and phase-contrast (electron phase) using P-STEM, along with a two-dimensional electron detector.