Safira Firdaus Mujiyanti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Safira Firdaus Mujiyanti has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- I. Putu Eka Widya Pratama
Department of Instrumentation Engineering, Faculty of Vocational Studies Institut Teknologi Sepuluh Nopember Surabaya Indonesia
2 shared publications - Dwi Nur Fitriyanah
Institut Teknologi Sepuluh Nopember
1 shared publication - Friska Aprilia Kusuma
Institut Teknologi Sepuluh Nopember
1 shared publication - Nabiilah Aziizah Tjandra
Institut Teknologi Sepuluh Nopember
1 shared publication - Putri Yeni Aisyah
Institut Teknologi Sepuluh Nopember
1 shared publication - Rico Pardona Pardosi
Institut Teknologi Sepuluh Nopember
1 shared publication
Latest Publications
- Open Access
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 5048-5054
Solar-based aerator with water quality monitoring in vannamei shrimp pond
The water quality is vital for the vannamei shrimp pond's productivity. Manual monitoring at Gunung Anyar's vannamei shrimp pond is time-consuming, ineffective, and potentially harmful. In this research, we developed a real-time monitoring system for the water quality of the vannamei shrimp pond. This monitoring system is integrated with a solar-based aerator. To address this, water quality monitoring in a solar-based aerator system tracks the degree of acidity (pH), temperature, and total dissolved solids (TDS) remotely using a website and real-time mobile phone Android application with 98.57% accuracy and 1.43% error. Seven days of data revealed the degree of acidity between 6.92 and 7.34 is indicated poor conditions of the pond While the temperatures from 23.59 °C to 38.32 °C, and TDS from 628.65 to 652.34 ppm indicate the good condition of the shrimp pond. This real-time monitoring system can help vannamei shrimp farmers monitor the actual conditions of their ponds.
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 5048-5054
Open AccessSolar-based aerator with water quality monitoring in vannamei shrimp pond
The water quality is vital for the vannamei shrimp pond's productivity. Manual monitoring at Gunung Anyar's vannamei shrimp pond is time-consuming, ineffective, and potentially harmful. In this research, we developed a real-time monitoring system for the water quality of the vannamei shrimp pond. This monitoring system is integrated with a solar-based aerator. To address this, water quality monitoring in a solar-based aerator system tracks the degree of acidity (pH), temperature, and total dissolved solids (TDS) remotely using a website and real-time mobile phone Android application with 98.57% accuracy and 1.43% error. Seven days of data revealed the degree of acidity between 6.92 and 7.34 is indicated poor conditions of the pond While the temperatures from 23.59 °C to 38.32 °C, and TDS from 628.65 to 652.34 ppm indicate the good condition of the shrimp pond. This real-time monitoring system can help vannamei shrimp farmers monitor the actual conditions of their ponds.
- Open Access
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (2) , 760-770
Dissolved oxygen control system in polishing unit using logic solver
The research consists of two parts, the first one is to design the dynamic plant model of polishing unit using artificial neural network (ANN) type backpropagation, and the second one is to design a simulation of a close loop control system on Simulink consisting of logic solver, control valve and ANN polishing unit. The ANN polishing unit was trained and obtained the best model structure 4-24-3 with four inputs chemical oxygen demand (COD) influent, oil in water (OIW) influent, urea, and triple superphosphate (TSP), twenty-four hidden layer nodes, and three outputs (OIW effluent, COD effluent and dissolved oxygen (DO)). The mean square error (MSE) and root mean square error (RMSE) from ANN trained were 0.00485 and 0.06964, obtained by the second iteration. From the simulation results on Simulink by giving several scenarios in the logic solver condition table, the action is brought in the form of urea and TSP nutrition issued by the control valve. The values are used to achieve the DO setpoint (2 mg/L), among others: when COD and OIW influent exceed the quality standard, COD exceeds the quality standard, and OIW does not exceed the quality standard, and the DO error is below zero.
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (2) , 760-770
Open AccessDissolved oxygen control system in polishing unit using logic solver
The research consists of two parts, the first one is to design the dynamic plant model of polishing unit using artificial neural network (ANN) type backpropagation, and the second one is to design a simulation of a close loop control system on Simulink consisting of logic solver, control valve and ANN polishing unit. The ANN polishing unit was trained and obtained the best model structure 4-24-3 with four inputs chemical oxygen demand (COD) influent, oil in water (OIW) influent, urea, and triple superphosphate (TSP), twenty-four hidden layer nodes, and three outputs (OIW effluent, COD effluent and dissolved oxygen (DO)). The mean square error (MSE) and root mean square error (RMSE) from ANN trained were 0.00485 and 0.06964, obtained by the second iteration. From the simulation results on Simulink by giving several scenarios in the logic solver condition table, the action is brought in the form of urea and TSP nutrition issued by the control valve. The values are used to achieve the DO setpoint (2 mg/L), among others: when COD and OIW influent exceed the quality standard, COD exceeds the quality standard, and OIW does not exceed the quality standard, and the DO error is below zero.