Vikash Shaw
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vikash Shaw has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Manfredo Atzori
Department of Neuroscience, University of Padua, Padua, Italy
4 shared publications - Sanjeev Kumar
Academy of Scientific and Innovative Research, Ghaziabad, India
4 shared publications - Sidharth Pancholi
Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
4 shared publications - Parul Rani
Academy of Scientific and Innovative Research, Ghaziabad, India
3 shared publications - Ahsan Habib Khandoker
Department of Biomedical Engineering and Biotechnology Khalifa University Abu Dhabi United Arab Emirates
1 shared publication - Dinesh Kant Kumar
School of Engineering, RMIT University, Melbourne, Australia
1 shared publication
Latest Publications
- Open Access
- 24 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt B) , 110814
How photoplethysmography can be used to detect major depressive disorder among patients with obstructive sleep apnea during sleep
- 24 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt B) , 110814
Open AccessHow photoplethysmography can be used to detect major depressive disorder among patients with obstructive sleep apnea during sleep
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (1) , 368-376
Explainable AI-Guided Optimization of EMG Channels and Features for Precise Hand Gesture Classification: A SHAP-Based Study
Extraction of the correct and efficient descriptors of muscular activity plays a vital role in tackling the challenging problem of myoelectric control of powered prostheses. This work presents a feature extraction framework that aims to enhance the representation of muscular activities by increasing the amount of information that can be extracted from individual and combined electromyogram (EMG) channels. The proposed method for feature selection is based on Shapley Additive explanations (SHAP). The SHAP value is used to reduce the feature dimension. The proposed approach has been evaluated on two datasets obtained at a sampling rate of 1 kHz through a band consisting of seven EMG channels. The Standard deviation (SD) and Integrated EMG (IEMG) of electrodes 3, 5, 6, and 7 recognized four motions with a classification accuracy of 98.42%± 1.16% and six gestures with a classification accuracy of 96.6%± 0.91%, respectively. In the present work, an ensemble technique called bagging in the random forest algorithm has been used to obtain the optimum results.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (1) , 368-376
Explainable AI-Guided Optimization of EMG Channels and Features for Precise Hand Gesture Classification: A SHAP-Based Study
Extraction of the correct and efficient descriptors of muscular activity plays a vital role in tackling the challenging problem of myoelectric control of powered prostheses. This work presents a feature extraction framework that aims to enhance the representation of muscular activities by increasing the amount of information that can be extracted from individual and combined electromyogram (EMG) channels. The proposed method for feature selection is based on Shapley Additive explanations (SHAP). The SHAP value is used to reduce the feature dimension. The proposed approach has been evaluated on two datasets obtained at a sampling rate of 1 kHz through a band consisting of seven EMG channels. The Standard deviation (SD) and Integrated EMG (IEMG) of electrodes 3, 5, 6, and 7 recognized four motions with a classification accuracy of 98.42%± 1.16% and six gestures with a classification accuracy of 96.6%± 0.91%, respectively. In the present work, an ensemble technique called bagging in the random forest algorithm has been used to obtain the optimum results.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1202-1211
Enhanced EMG-Based Hand Gesture Classification in Real-World Scenarios: Mitigating Dynamic Factors With Tempo-Spatial Wavelet Transform and Deep Learning
Dynamic factors, like limb position changes and electrode shifting, significantly impact the performance of EMG-based hand gesture classification as the transition is made from a laboratory-controlled environment to real-life scenarios. Traditionally, researchers have employed conventional wavelet transform methods to improve classification performance. This study compares a tempo-spatial technique that utilizes the wavelet multiresolution method and compares it with the conventional wavelet transform using eight machine learning algorithms. Two public datasets are utilized. DB1 comprising ideal conditions with a range of limb positions, while DB2 incorporates dynamic factors like electrode shifting and muscle fatigue. The training/testing involves two cases: one using single-position data and other with multiple positions. Results demonstrate that the Deep Neural Network (DNN) classifier outperforms others in classification accuracy. Proposed technique achieves mean accuracies of 84.07% (DB1) and 68.15% (DB2), while conventional wavelet transform methods achieve 79.39% (DB1) and 53.48% (DB2) for single-position DNN training. For multiple positions, particularly two limb positions, the proposed technique achieves mean accuracies of 94.43% (DB1) and 73.79% (DB2), compared to conventional wavelet transform, which achieves 84.38% (DB1) and 51.98% (DB2) with DNN. Paired t-tests (p-value<0.001) show significant improvement over conventional wavelet transformation, indicating the proposed technique’s potential to enhance gesture classification in real-world scenarios.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1202-1211
Enhanced EMG-Based Hand Gesture Classification in Real-World Scenarios: Mitigating Dynamic Factors With Tempo-Spatial Wavelet Transform and Deep Learning
Dynamic factors, like limb position changes and electrode shifting, significantly impact the performance of EMG-based hand gesture classification as the transition is made from a laboratory-controlled environment to real-life scenarios. Traditionally, researchers have employed conventional wavelet transform methods to improve classification performance. This study compares a tempo-spatial technique that utilizes the wavelet multiresolution method and compares it with the conventional wavelet transform using eight machine learning algorithms. Two public datasets are utilized. DB1 comprising ideal conditions with a range of limb positions, while DB2 incorporates dynamic factors like electrode shifting and muscle fatigue. The training/testing involves two cases: one using single-position data and other with multiple positions. Results demonstrate that the Deep Neural Network (DNN) classifier outperforms others in classification accuracy. Proposed technique achieves mean accuracies of 84.07% (DB1) and 68.15% (DB2), while conventional wavelet transform methods achieve 79.39% (DB1) and 53.48% (DB2) for single-position DNN training. For multiple positions, particularly two limb positions, the proposed technique achieves mean accuracies of 94.43% (DB1) and 73.79% (DB2), compared to conventional wavelet transform, which achieves 84.38% (DB1) and 51.98% (DB2) with DNN. Paired t-tests (p-value<0.001) show significant improvement over conventional wavelet transformation, indicating the proposed technique’s potential to enhance gesture classification in real-world scenarios.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 5246-5255
Enhancing Gesture Classification Using Active EMG Band and Advanced Feature Extraction Technique
This study addresses two critical aspects of gesture classification: data acquisition and feature extraction. It introduces an efficient surface electromyogram (sEMG) acquisition band with seven active electrodes and conducts experiments with eight healthy subjects for six gestures. A novel feature extraction method, the Hjorth secant line (HSL), is also introduced. The self-generated dataset (DB1) and two publicly available datasets (DB2 and DB3), containing data from both healthy subjects and amputees, are analyzed to assess the proposed feature set’s performance. The study evaluates the sEMG acquisition system’s effectiveness by measuring the signal-to-noise ratio (SNR), and the performance of the proposed feature set was evaluated in terms of gesture classification accuracy. The feature set’s performance is compared to other existing feature sets in the literature. Additionally, a time complexity analysis is performed for the proposed feature set. The SNR for the sEMG acquisition system is 49.36±5.50 dB, demonstrating its efficiency. When using the proposed feature set with a Random Forest (RF) classifier, the study achieves classification accuracy of 97.94%±0.47%, 98.94%±0.46%, and 82.16%±2.07% for DB1, DB2, and DB3, respectively. Paired t-tests indicate that the proposed feature set significantly improves gesture classification accuracy across all three datasets (p-value < 0.05). The time required to calculate the proposed features was 0.207 msec, which is shorter than the computational time for other feature extraction methods reported in the literature. This study highlights the enhanced SNR from the proposed acquisition system and the feature set’s potential to improve gesture classification. These findings have substantial implications for advancing intelligent prosthetics.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 5246-5255
Enhancing Gesture Classification Using Active EMG Band and Advanced Feature Extraction Technique
This study addresses two critical aspects of gesture classification: data acquisition and feature extraction. It introduces an efficient surface electromyogram (sEMG) acquisition band with seven active electrodes and conducts experiments with eight healthy subjects for six gestures. A novel feature extraction method, the Hjorth secant line (HSL), is also introduced. The self-generated dataset (DB1) and two publicly available datasets (DB2 and DB3), containing data from both healthy subjects and amputees, are analyzed to assess the proposed feature set’s performance. The study evaluates the sEMG acquisition system’s effectiveness by measuring the signal-to-noise ratio (SNR), and the performance of the proposed feature set was evaluated in terms of gesture classification accuracy. The feature set’s performance is compared to other existing feature sets in the literature. Additionally, a time complexity analysis is performed for the proposed feature set. The SNR for the sEMG acquisition system is 49.36±5.50 dB, demonstrating its efficiency. When using the proposed feature set with a Random Forest (RF) classifier, the study achieves classification accuracy of 97.94%±0.47%, 98.94%±0.46%, and 82.16%±2.07% for DB1, DB2, and DB3, respectively. Paired t-tests indicate that the proposed feature set significantly improves gesture classification accuracy across all three datasets (p-value < 0.05). The time required to calculate the proposed features was 0.207 msec, which is shorter than the computational time for other feature extraction methods reported in the literature. This study highlights the enhanced SNR from the proposed acquisition system and the feature set’s potential to improve gesture classification. These findings have substantial implications for advancing intelligent prosthetics.
- Open Access
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Active Surface Electromyogram (sEMG) Electrodes band with Enhanced Features based technique for Hand Gesture Classification
The proposed EMG data acquisition band, which utilizes seven electrodes, has the potential to revolutionize gesture recognition. Unlike conventional EMG data acquisition methods that necessitate skin preparation and can cause skin irritation or adverse reactions, this band is inexpensive, user-friendly, and capable of capturing high-quality EMG signals. Our study evaluated the performance of the proposed EMG band by comparing it with established techniques on eight healthy subjects, and the results revealed that it achieved comparable or significantly better performance in terms of classification accuracy. This suggests that our EMG data acquisition band has significant practical applications, particularly in prosthetic hand control, where real-time processing is critical. Moreover, The proposed feature extraction method based on spectral moments also exhibited significant improvements in terms of classification accuracy, class separability, and processing time, making it a promising alternative for gesture recognition applications. Additionally, the proposed feature set was computationally efficient, with a maximum computation time of 250.209 milliseconds, making it suitable for real-time prosthetic hand control.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessActive Surface Electromyogram (sEMG) Electrodes band with Enhanced Features based technique for Hand Gesture Classification
The proposed EMG data acquisition band, which utilizes seven electrodes, has the potential to revolutionize gesture recognition. Unlike conventional EMG data acquisition methods that necessitate skin preparation and can cause skin irritation or adverse reactions, this band is inexpensive, user-friendly, and capable of capturing high-quality EMG signals. Our study evaluated the performance of the proposed EMG band by comparing it with established techniques on eight healthy subjects, and the results revealed that it achieved comparable or significantly better performance in terms of classification accuracy. This suggests that our EMG data acquisition band has significant practical applications, particularly in prosthetic hand control, where real-time processing is critical. Moreover, The proposed feature extraction method based on spectral moments also exhibited significant improvements in terms of classification accuracy, class separability, and processing time, making it a promising alternative for gesture recognition applications. Additionally, the proposed feature set was computationally efficient, with a maximum computation time of 250.209 milliseconds, making it suitable for real-time prosthetic hand control.