Zhengwei Mei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhengwei Mei has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hailin Bi
School of Mechanical Engineering, Hefei University of Technology 1 , Hefei 230009
4 shared publications Wenyu Lin
National Synchrotron Radiation Laboratory, University of Science and Technology of China 2 , Hefei 230029
4 shared publicationsXudi Wang
School of Mechanical Engineering, Hefei University of Technology 1 , Hefei 230009
4 shared publications- Wenyu Lin
School of Mechanical Engineering, Hefei University of Technology 1 , Hefei 230009, China
2 shared publications - Xudi Wang
School of Mechanical Engineering, Hefei University of Technology 1 , Hefei 230009, China
2 shared publications - Bingxin Wu
School of Mechanical Engineering, Hefei University of Technology 1 , Hefei 230009
1 shared publication
Latest Publications
- 22 May 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (4)
Fabrication of soft x-ray windows based on multilayer graphene films
Soft x-ray windows are critical components for enabling the transmission of x rays from vacuum to the atmosphere. Existing windows face several challenges, including high absorption rates, degradation, complex fabrication processes, and limited transmission efficiency. This paper presents the design of a graphene-based soft x-ray window, leveraging the material’s exceptional optical transparency and impermeability to gases. The window consists primarily of a graphene film deposited on a porous tungsten foil, fabricated using chemical vapor deposition and etching techniques. The study demonstrates that the graphene window exhibits high uniformity, excellent mechanical strength, and robust vacuum sealing properties. The leakage rate of the graphene window increases linearly within the helium gas pressure range of 5–120 kPa, with a maximum leakage rate not exceeding 2 × 10−8 Pa m3 s−1. For soft x rays with energies ranging from 100 to 1000 eV, the graphene window shows an average transmission rate of up to 55%, with the transmission in the self-supporting region reaching as high as 84%, significantly outperforming traditional silicon nitride windows. This novel soft x-ray window has potential applications in fields such as materials characterization, medical diagnostics, and micro- and nanofabrication.
- 22 May 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (4)
Fabrication of soft x-ray windows based on multilayer graphene films
Soft x-ray windows are critical components for enabling the transmission of x rays from vacuum to the atmosphere. Existing windows face several challenges, including high absorption rates, degradation, complex fabrication processes, and limited transmission efficiency. This paper presents the design of a graphene-based soft x-ray window, leveraging the material’s exceptional optical transparency and impermeability to gases. The window consists primarily of a graphene film deposited on a porous tungsten foil, fabricated using chemical vapor deposition and etching techniques. The study demonstrates that the graphene window exhibits high uniformity, excellent mechanical strength, and robust vacuum sealing properties. The leakage rate of the graphene window increases linearly within the helium gas pressure range of 5–120 kPa, with a maximum leakage rate not exceeding 2 × 10−8 Pa m3 s−1. For soft x rays with energies ranging from 100 to 1000 eV, the graphene window shows an average transmission rate of up to 55%, with the transmission in the self-supporting region reaching as high as 84%, significantly outperforming traditional silicon nitride windows. This novel soft x-ray window has potential applications in fields such as materials characterization, medical diagnostics, and micro- and nanofabrication.
- 18 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
Numerical analysis of high vacuum packaging efficiency for narrow structured devices
High vacuum packaging is the key manufacturing technology of passive vacuum devices. The inherent characteristics of narrow and long space and large surface-to-volume ratio make it challenging to effectively remove the desorption gas inside the device. To this end, the pressure distribution of two standard packaging methods during the pump-down process is investigated using the two-dimensional diffusion equation. Experiments and simulations show that a pressure gradient persists within the slit even when pumping reaches the quasi-equilibrium state. In addition, a Monte Carlo method based on the cosine law reveals that the high-frequency collisions of gas molecules with the walls impede the pumping process. Furthermore, the results indicate that for tube pumping, the number of collisions of gas molecules with the wall during transport within the gap is inversely proportional to the gap height. For edge pumping, the number of collisions is inversely proportional to the square of the gap height. This provides a theoretical basis for efficient high vacuum packaging and long-term pressure maintenance for passive vacuum devices.
- 18 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
Numerical analysis of high vacuum packaging efficiency for narrow structured devices
High vacuum packaging is the key manufacturing technology of passive vacuum devices. The inherent characteristics of narrow and long space and large surface-to-volume ratio make it challenging to effectively remove the desorption gas inside the device. To this end, the pressure distribution of two standard packaging methods during the pump-down process is investigated using the two-dimensional diffusion equation. Experiments and simulations show that a pressure gradient persists within the slit even when pumping reaches the quasi-equilibrium state. In addition, a Monte Carlo method based on the cosine law reveals that the high-frequency collisions of gas molecules with the walls impede the pumping process. Furthermore, the results indicate that for tube pumping, the number of collisions of gas molecules with the wall during transport within the gap is inversely proportional to the gap height. For edge pumping, the number of collisions is inversely proportional to the square of the gap height. This provides a theoretical basis for efficient high vacuum packaging and long-term pressure maintenance for passive vacuum devices.
- Open Access
- 1 September 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (5)
Investigation of the intrinsic outgassing rates for narrow structured vacuum devices under readsorption effect
The narrow structure within the vacuum system usually results in a slow evacuation process. Additionally, the high outgassing rate caused by the large surface-to-volume ratio can prevent the vacuum level from meeting the performance requirements of the device. In this paper, the evacuation of the stainless steel parallel plates is established based on a two-dimensional equation combined with the outgassing theory of the recombination–dissociation-limited model. The relationship between the measured and intrinsic outgassing rates was investigated by varying the gap size, pump-out port size, and temperature. The results show that the internal pressure is nonuniformly distributed during the pump-down process, even reaching a quasiequilibrium state. This indicates that the widely used throughput method can make a difference in measuring outgassing rates. This provides a theoretical basis for testing intrinsic outgassing rates, calculating pressure distribution, and configuring pumps or getters in complex vacuum systems.
- 1 September 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (5)
Open AccessInvestigation of the intrinsic outgassing rates for narrow structured vacuum devices under readsorption effect
The narrow structure within the vacuum system usually results in a slow evacuation process. Additionally, the high outgassing rate caused by the large surface-to-volume ratio can prevent the vacuum level from meeting the performance requirements of the device. In this paper, the evacuation of the stainless steel parallel plates is established based on a two-dimensional equation combined with the outgassing theory of the recombination–dissociation-limited model. The relationship between the measured and intrinsic outgassing rates was investigated by varying the gap size, pump-out port size, and temperature. The results show that the internal pressure is nonuniformly distributed during the pump-down process, even reaching a quasiequilibrium state. This indicates that the widely used throughput method can make a difference in measuring outgassing rates. This provides a theoretical basis for testing intrinsic outgassing rates, calculating pressure distribution, and configuring pumps or getters in complex vacuum systems.