NDNamrata Dogra

Namrata Dogra

*This is an algorithmically generated author record based on publicly available information.

Namrata Dogra has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of treatment effects of herbst and advansync appliances on hyoid bone position and cervical posture in skeletal class II malocclusion – A prospective randomized clinical trial

    by Archana Jaglan, Seema Grover, Namrata Dogra, Pandurangan Harikrishnan

    Mandibular retrusion is the most common cause of Class II Division 1 malocclusion, which needs correction of the underlying skeletal discrepancy. The objective of this study was to evaluate the Hyoid bone position and cervical posture changes following treatment with two fixed functional appliances - Herbst and Advansync (Ormco, Orange, CA, USA) appliances in skeletal Class II malocclusion using pre and post treatment lateral cephalograms.For this randomized controlled trial,40 patients(21males and 19 females) were divided into two groups Group I, Herbst Appliance group (mean age: 12.6 +/- 0.67 years) and Group II, Advansync group (mean age: 12.8 +/- 0.66yrs). Pre and post-treatment (after appliance therapy of 8 months duration) lateral cephalograms were evaluated using Planmeca Romexis software 5.0.0.R version for hyoid bone position and cervical posture changes. The Hyoid bone had displaced anteriorly by 1.64 mm in Group I and in Group II by 1.97 mm. There was downward displacement of hyoid bone by 1.73 mm in Group I and 2.03 mm in Group II with reference to the Frankfort horizontal (FH) plane. The Mandibular plane-Odontoid process tangent angle used for determining upper cervical posture decreased by 7.13 in Group I, while by 0.33in Group II. This study concluded that both Herbst and Advansync appliances showed an improvement in hyoid bone position and the cervical posture while Advansync appliance demonstrated greater uprighting of cervical posture which was statistically significant.

  • Open Access

    Behavior of CuO as solid lubricant inside ZTA matrices

    by Bipin Kumar Singh, Amit Kumar, Robert Cep, Ajay Kumar, Ashwini Kumar, Namrata Dogra, K. Logesh

    This investigation delves into the behavior of copper oxide (CuO) as a solid lubricant inside zirconia toughened alumina (ZTA) ceramic composites. The investigation starts with the preparation of ZTA through co-precipitation followed by powder metallurgy to develop CuO (1.5 wt. %)/ZTA composites. In all cases, hot isotactic pressing is applied for densification. The fully densified samples are thoroughly mirror-polished to investigate the mechanical and tribological properties. A 1.8% reduction in micro-hardness and 6% improvement in fracture toughness are observed with incorporation of CuO into the ZTA matrices. The analysis reveals that the presence of ionic copper at the grain boundary leads to the formation of copper-rich phases, causing a decrease in hardness. However, the softer CuO particles contribute to crack bridging and crack deflection, enhancing fracture toughness. Subsequent investigation into the tribological properties highlights the positive influence of the softer CuO phases acting as a secondary component within the ZTA matrix. A significant enhancement of 39.34% in the Coefficient of Friction (COF) is achieved by incorporating CuO into the ZTA matrix. This improvement can be attributed to the formation of a patchy layer through smearing and squeezing actions on wear debris during sliding. The uniform patchy layer results in smoother and more polished surfaces, leading to an improvement in both the COF and specific wear rate. Further wear analysis reveals various phenomena contributing to surface wear, including pullout of grain particles, micro-fracture, high abrasions, and laminar removal of grains. Overall, the introduction of CuO proves to be beneficial, showcasing improved mechanical and tribological properties in the developed composites, with application in dies, inserts, sparkplugs, etc.


  • The Era of Telemedicine

    by Deepika Dahiya, Manisha Khanna, Namrata Dogra, Archana Jaglan

    The dynamics of dental care delivery could alter and be improved via teledentistry. In this area, clinical data and images are transmitted over great distances in order to facilitate diagnosis the treatment plans and professional consultation. Majority of Indians reside in rural regions and cannot access proper oral health care due lack of access to transportation, awareness, expertise, and others. The Global Burden of Disease (2016) report listed oral disorders as the most prevalent and avoidable Non-communicable Diseases (NCDs), affecting half of the world's population. “Use of Digital Technology to Improve Oral Health” is one of the five main pillars of the WHO oral health programme's timeframe from 2018 to 2020 to reduce the burden of oral diseases. The recent COVID-19 disease outbreak has raised significant public concern. This type of illness has an economic impact on society as a whole since it causes unanticipated illnesses and fatalities as well as disruptions in travel plans, business, and regular daily activities, including elective dentistry procedures. The use of technologies to aid in the attainment of health goals in this unique environment has the potential to alter how health services are delivered all over the world.


  • Handbook of Intelligent and Sustainable Smart Dentistry

    by Ajay Kumar, Namrata Dogra, Sarita, Surbhi Bhatia, M S Sidhu

    With the exponential growth of science and technology, the delivery of dental care has shifted from conventional methods to intelligent techniques. In addition to adapting intelligent techniques, sustainable dental practice is of the utmost importance. Eco-friendly dentistry, sustainable dentistry, or green dentistry are approaches that reduce the environmental impact of dental practice and help safeguard planetary and community well-being. This handbook provides the latest and most comprehensive evidence-based guidance on intelligent and sustainable approaches in dentistry. Handbook of Intelligent and Sustainable Smart Dentistry: Nature and Bio-Inspired Approaches, Processes, Materials, and Manufacturing highlights how Dentistry 4.0 has come to the rescue after COVID-19 and how it has helped in providing needed e-healthcare. This handbook bridges the gap between research and development in the field of smart dentistry for professionals and clinicians. Intelligent materials, equipment, instrumentation, and the latest behavior management techniques and how these techniques provide superior care and treatment to society are explored in detail. The scope of nature-inspired techniques and procession, along with green solutions, are also discussed in this one-of-a-kind handbook. This valuable handbook is a single-stop solution for practitioners, researchers, scholars, students, academicians, and clinicians interested in updating their knowledge on intelligent and sustainable dentistry. The handbook will bestow the readers with not only theoretical knowledge but will equip them with clinical skills as well.


  • Open Access

    A comparison of the shear bond strength of metal orthodontic brackets that have been treated with various light-emitting diode intensities and curing times: In-vitro research

    by Gananjay Patil, Santosh Kumar, Namrata Dogra, Jasmine Nindra, Satwashila Kadam, Krishna Yadav

    The study aims to test the effects of LED light at three different power settings (500mW/cm2, 1000mW/cm2& 1500m W/cm2) and three different exposure times (5sec, 10sec & 20sec) adhesive composites for use with stainless steel orthodontic brackets, and their shear bond strengths. Current In-vitro work used 120 teeth, mostly premolars, separated into 10 equal groups of 12. After the crowns of the teeth were exposed by mounting them vertically into self-heal acrylics, the buccal-enamel exterior was prepared for bonding (PEA) 0.022”x 0.028” stainless steel premolar bracket using a thin layer of light cure adhesive primer and paste (Transbond-XT-3M Unitek Monrovia, Calif). Brackets in Group 1 comprising the Control group treated by usual halogen light source for forty sec, in remaining 9 groups (Experimental group) three commercially available LED curing light units i.e., Woodpecker, Guilin, Guangxi, China; Stealth Soft Equinox, Denmark, Holland; Radii plus, SDI, Australia, having three different light intensity 500mW/cm2, 1000mW/cm2, 1500mW/cm2 respectively were used to bond the brackets at three contact time (5/10/20 sec). The universal testing equipment was used to determine the shear bond strength of each specimen. The uppermost average SBS was found in the group cured with LED of intensity 1500 mW/cm2 for 20 sec (20.08 + 4.82 MPa) which was statistically significant compared the to control group (12.72 + 2.42 MPa). The lowest mean SBS values were obtained for groups cured with LED of intensity 500 mW/cm2 even at different curing times of 5, 10 and 20 sec i.e., 5.46 + 1.99 MPa, 8.77 + 2.38 Mpa and 11.24 + 2.59 MPa, respectively. Increasing the intensity of the LED light curing unit provides a clinically acceptable SBS even after reducing the curing times, thereby reducing the chairside time for bonding of orthodontic brackets.The study aims to test the effects of LED light at three different power settings (500mW/cm2, 1000mW/cm2& 1500m W/cm2) and three different exposure times (5sec, 10sec & 20sec) adhesive composites for use with stainless steel orthodontic brackets, and their shear bond strengths. Current In-vitro work used 120 teeth, mostly premolars, separated into 10 equal groups of 12. After the crowns of the teeth were exposed by mounting them vertically into self-heal acrylics, the buccal-enamel exterior was prepared for bonding (PEA) 0.022”x 0.028” stainless steel premolar bracket using a thin layer of light cure adhesive primer and paste (Transbond-XT-3M Unitek Monrovia, Calif). Brackets in Group 1 comprising the Control group treated by usual halogen light source for forty sec, in remaining 9 groups (Experimental group) three commercially available LED curing light units i.e., Woodpecker, Guilin, Guangxi, China; Stealth Soft Equinox, Denmark, Holland; Radii plus, SDI, Australia, having three different light intensity 500mW/cm2, 1000mW/cm2, 1500mW/cm2 respectively were used to bond the brackets at three contact time (5/10/20 sec). The universal testing equipment was used to determine the shear bond strength of each specimen. The uppermost average SBS was found in the group cured with LED of intensity 1500 mW/cm2 for 20 sec (20.08 + 4.82 MPa) which was statistically significant compared the to control group (12.72 + 2.42 MPa). The lowest mean SBS values were obtained for groups cured with LED of intensity 500 mW/cm2 even at different curing times of 5, 10 and 20 sec i.e., 5.46 + 1.99 MPa, 8.77 + 2.38 Mpa and 11.24 + 2.59 MPa, respectively. Increasing the intensity of the LED light curing unit provides a clinically acceptable SBS even after reducing the curing times, thereby reducing the chairside time for bonding of orthodontic brackets.


  • Open Access

    CBCT evaluation of apical root resorption in maxillary and mandibular anterior teeth in orthodontic patients

    by Deepika Yadav, Santosh Kumar, Namrata Dogra, Ashish Dabas, Mona Prabhakar, Pandurangan Harikrishnan, Harshal Tare

    Introduction: One of the drawbacks of getting braces is root resorption. CBCT's high spatial resolution makes it a useful tool for gauging the extent to which external root resorption has occurred. Aim: Patients with bimaxillary protrusion receiving fixed orthodontic therapy will have CBCT scans taken of their upper and lower anterior teeth to check the degree of apical root re-sorption. Materials and Methods: This article focuses on retrospective data of 15 patients with dento-alveolar protrusion treated with all initial premolar extraction and fixed orthodontic mechanotherapy. Each patient had pretreatment & post-retraction CBCT scans of upper and lower anteriors which were compared to measure changes in root length, root volume and root apex displacement. Results: Mean root length of maxillary and mandibular anteriors showed significant difference from pre-treatment to post-retraction. The root volume of maxillary anteriors and mandibular anteriors except for the root volume of mandibular lateral incisor showed statistically significantly decrease at post-retraction. Angular mean root apex displacement of canine and mandibular & maxillary central incisor, also lateral incisor showed significant differences from pre-treatment to post-retraction. Conclusion: Roots of teeth can be altered with orthodontic therapy. After retraction, there was a decrease in root length in root volume, although these alterations were within a clinically feasible range.

  • Cephalometric evaluation of pharyngeal airway and tongue space following treatment with Herbst and AdvanSync appliances

    by Suman Arora, Seema Grover, Pandurangan Harikrishnan, Ashish Dabas, Namrata Dogra, Jasmine Nindra

    Objectives To evaluate and compare pharyngeal airway and tongue space changes after treatment with fixed functional appliances—Herbst and AdvanSync™ (Ormco, Orange, CA, USA) appliances—in skeletal class II patients in pre- and posttreatment lateral cephalograms. Methods For this randomized, controlled trial, 40 patients (21 male, 19 female) were divided into two groups—a Herbst group (mean age 12.6 ± 0.67 years) and an AdvanSync group (mean age 12.8 ± 0.66 years). Pre- and posttreatment (appliance therapy duration—8 months) lateral cephalograms were traced using a software program to evaluate pharyngeal airway and tongue space changes. Results Nasopharyngeal airway, velopharyngeal airway, glossopharyngeal airway, and hypopharyngeal airway increased in the Herbst group by 2.12 mm (p ≤ 0.001), 2.33 mm (p ≤ 0.001), 2.40 mm (p ≤ 0.01), and 1.57 mm (p ≤ 0.05), while in the AdvanSync group the increases were 1.89 mm (p ≤ 0.001), 1.21 mm (p ≤ 0.001), 1.18 mm (p ≤ 0.001), and 1.53 mm (p ≤ 0.001), respectively. In the Herbst group, tongue length and height increases were 2.04 mm (p ≤ 0.01) and 3.74 mm (p ≤ 0.001), while the values in the AdvanSync group were 2.41 mm (p ≤ 0.05) and 2.69 mm (p ≤ 0.001). The change of the tongue tip from the lower occlusal plane was 0.69 mm (p ≤ 0.001) in the Herbst group and 0.77 mm (p ≤ 0.001) in the AdvanSync group. The velopharyngeal airway dimension was correlated positively with that of the retroglossal oropharyngeal airway, which in-turn positively correlated with the laryngopharyngeal airway which correlated well with the distance of the tongue tip from the lower occlusal plane. Conclusions The airway dimensions and tongue parameters increased significantly in both treatment groups in the present study. These changes were higher in the Herbst appliance than in the AdvanSync group, except for the distance of the tongue tip from the lower occlusal plane. A significant difference between the pharyngeal airways was found only for the retropalatal oropharyngeal airway.


  • Impact of artificial intelligence on civilization: Future perspectives

    by P. Rajendra, Mina Kumari, Sangeeta Rani, Namrata Dogra, Rahul Boadh, Ajay Kumar, Mamta Dahiya