ABArmando Daniel Blanco-Jáquez

Armando Daniel Blanco-Jáquez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Armando Daniel Blanco-Jáquez has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temporal Generalization of RAFT, FastFlowNet, and Farnebäck for KLT-IV-Referenced River-Surface Velocity Prediction Using the River Dart Dataset

    by Oscar Abel González-Vergara, Samuel Villarreal Rodríguez, Ana Elizabeth Marín Celestino, Yolocuauhtli Salazar-Muñoz, Armando Daniel Blanco-Jáquez, Joel García-Pazos, Diego Armando Martínez Cruz

    Open hydrometric image archives enable controlled evaluation of computer-vision methods under realistic temporal variability. This study compared pretrained RAFT and FastFlowNet with classical Farnebäck for reproducing KLT-IV-derived mean river-surface velocity in the open River Dart dataset. Dense optical-flow fields were reduced to six video-level descriptors and mapped to the KLT-IV reference using a common random-forest framework. Model development used five-fold purged contiguous blocked cross-validation, while 5,910 chronologically later videos were reserved for validation. Uncertainty was quantified by moving-block bootstrap resampling with elapsed-time sensitivity analyses. RAFT achieved the highest blocked-calibration R² (0.934), followed by FastFlowNet (0.925) and Farnebäck (0.908). In validation, however, FastFlowNet performed best (R² = 0.940, MAE = 0.0621 m s⁻¹, RMSE = 0.0875 m s⁻¹), reducing MAE by 17.1% relative to RAFT (0.0128 m s⁻¹ absolute difference) and 23.6% relative to Farnebäck. The ranking was unchanged with an ordinary least-squares baseline and remained stable across alternative temporal-purge and bootstrap-block specifications. Performance deteriorated at or above 2.0 m s⁻¹, where only 0.47% of calibration observations were available. FastFlowNet also required approximately 63% less optical-flow inference time per frame pair than RAFT under the evaluated implementation and common preprocessing conditions used here. These results demonstrate that optical-flow rankings obtained during model development may not persist under chronologically separated field evaluation, highlighting temporal generalization as a distinct criterion for comparative image-velocimetry assessment. Greater optical-flow complexity did not necessarily yield stronger later-period performance.

  • Open Access

    Design and field validation of a low-power NB-IoT piezometric monitoring system for groundwater level monitoring

    by Armando Daniel Blanco-Jáquez, María Teresa Alarcón-Herrera, Ana Elizabeth Marín-Celestino, Luz I. Valenzuela-García, Samuel Villarreal Rodríguez, Joel García-Pazos, Diego Armando Martínez-Cruz

  • Open Access

    Portable Multispectral Fluorometer with Embedded Machine Learning for Chlorophyll-a Estimation in Acetone-Extracted Samples

    by Armando Daniel Blanco-Jáquez, María Teresa Alarcón-Herrera, Luz I. Valenzuela-García, Ana Elizabeth Marín-Celestino, Samuel Villarreal-Rodríguez, Víctor M. Ayala-García, Finlandia Barbosa-Moreno, Diego Armando Martínez-Cruz

    Chlorophyll-a (Chl-a) is commonly used as an indicator of phytoplankton biomass and water quality, but its determination usually depends on laboratory-based methods and specialized equipment. In this work, a portable multispectral fluorometer was developed and evaluated for Chl-a estimation in 90% acetone extracts prepared from water samples. The system integrates a nominal 420–425 nm fluorescence excitation source, 90° detection geometry, two multispectral sensors (AS7341 and AS7343), an ESP32-S3 microcontroller, and an Android application for device control and result visualization. A dataset of 76 samples was used for model development, including regression-model benchmarking, model selection, and internal testing. A Random Forest model selected for embedded implementation was exported to C++ for on-device inference. Validation using 15 independent samples yielded R2 = 0.979, root mean square error (RMSE) = 35.41 µg/L, mean absolute error (MAE) = 28.91 µg/L, and mean absolute percentage error (MAPE) = 6.14%. Agreement analysis showed a positive bias of 22.00 µg/L, while repeatability tests showed a maximum coefficient of variation (CV) of 3.29%. Embedded inference was highly consistent with Python predictions (R2 = 0.997). These results suggest that the system is a promising portable alternative for Chl-a estimation in prepared acetone extracts under the evaluated conditions.

  • Open Access

    Design and field validation of a low-power NB-IoT piezometric monitoring system for groundwater level monitoring

    by Armando Daniel Blanco-Jáquez, Maria Alarcon, Ana Elizabeth Marín Celestino, Luz Idalia Valenzuela García, Samuel Villarreal Rodríguez, Joel García-Pazos, Diego Armando Martínez Cruz

    Groundwater monitoring is fundamental for aquifer management and hydrogeological studies. Systems that can obtain reliable, long-term information to detect nonlinear and nonseasonal variations are primarily required. However, existing solutions (both commercial and research-oriented) have certain limitations, such as high installation or operating costs, closed architectures, and the need for periodic site visits, all of which limit or prevent their general application in long-term monitoring campaigns in remote locations.,This paper presents the design and field validation of a low-power NB-IoT-based piezometric monitoring system for groundwater levels. The system integrates a submersible pressure sensor, an embedded ESP32-based controller, wireless transmission via an NB-IoT network, energy management, and a cloud platform for data storage and visualization.,The developed system was evaluated in a groundwater observation well for 63 days. The collected data were used to assess short-term variability, daily stability, temporal consistency, communication reliability, and energy consumption under real operating conditions.,Results showed stable system performance, with a maximum daily standard deviation below 2.1 cm (less than 4% of the total observed range), no evidence of progressive drift in recorded measurements, and data availability exceeding 97%. Energy analysis revealed a duty-cycled operation with an average consumption of approximately 670.9 mWh day⁻¹, enabling an estimated autonomy of 25–30 days using a 5000 mAh battery.,Overall, the proposed system demonstrates reliable, low-power, and scalable operation under real field conditions, supporting its application in long-term groundwater monitoring and distributed sensor networks.

  • Open Access

    A Systematic Review of River Discharge Measurement Methods: Evolution and Modern Applications in Water Management and Environmental Protection

    by Oscar Abel González-Vergara, María Teresa Alarcón-Herrera, Ana Elizabeth Marín-Celestino, Armando Daniel Blanco-Jáquez, Joel García-Pazos, Samuel Villarreal-Rodríguez, Yolocuauhtli Salazar, Diego Armando Martínez-Cruz

    Accurate river discharge estimation is fundamental for water resource management under increasingly variable hydrological conditions. While conventional in situ techniques remain hydrometric reference standards, their operational deployment is constrained by cost, accessibility, and limited spatial coverage. Advances in remote sensing and artificial intelligence (AI) have introduced non-contact discharge estimation frameworks based on image-derived observations. This systematic review, conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 reporting guidelines, examines the evolution of river discharge measurement methods between 2004 and 2024 through a structured two-stage design. An initial search in Web of Science and Scopus identified 2809 records, of which 249 were retained for first-stage synthesis. A focused second-stage screening isolated seven studies that directly integrate image-based data with machine learning or deep learning architectures for discharge estimation. The analysis reveals a methodological transition from instrument-based hydrometry toward computationally assisted, image-driven approaches. The retained studies employ close-range and satellite imagery combined with Convolutional Neural Networks (CNNs), Long Short-Term Memory networks (LSTMs), and related models. Although reported validation metrics indicate strong predictive capability under specific conditions, performance remains dependent on site-specific calibration and reference discharge records. Broader operational deployment requires improved transferability, uncertainty integration, and cross-basin validation.


  • Open Access

    Evaluation of the Extreme Precipitation and Runoff Flow Characteristics in a Semiarid Sub-Basin Based on Three Satellite Precipitation Products

    by Rosalía López Barraza, María Teresa Alarcón Herrera, Ana Elizabeth Marín Celestino, Armando Daniel Blanco Jáquez, Diego Armando Martínez Cruz

    In this study, we analyzed the suitability of using the CHIRPS, CMORPH and TRMM platforms in monitoring extreme precipitation events, precipitation–runoff relationships, and seasonal/year-to-year variability in the Saltito semiarid sub-basin in the Mexican state of Durango. Satellite precipitation products (SPP) in 16 sites were contrasted point to point with data from rainfall gauge stations and with a daily temporal resolution for the period of four years (2015–2019). Using this information, we constructed Rx1d, Rx2d, R25mm, and RR95 extreme rainfall indices. For the precipitation–runoff relationships, a runoff model based on the Storm Water Management Model (SWMM) was calibrated and validated with gauge data, and we obtained the Qx1d, Qx2d, and Qx3d runoff indices. We used the bias volume (%), MSE, correlation coefficient, and median bias to evaluate the ability of satellite products to detect and analyze extreme precipitation and run flow events. Although these sensors tend to overestimate both precipitation levels and the occurrence of extreme precipitation events, their high spatial and temporal resolutions make them a reliable tool for the analysis of trends in climate change indices. As a result, they serve as a useful resource in evaluating the intensity of climate change in the region, particularly in terms of precipitation patterns. They also allow hydrological modeling and the observation of precipitation–runoff relationships. This is relevant in the absence of precipitation and hydrometric information, which is usually common in vast regions of the developing world.


  • Open Access

    Extension of LoRa Coverage and Integration of an Unsupervised Anomaly Detection Algorithm in an IoT Water Quality Monitoring System

    by Armando Daniel Blanco Jáquez, María T. Alarcon Herrera, Ana Elizabeth Marín Celestino, Efraín Neri Ramírez, Diego Armando Martínez Cruz

    High cost, long-range communication, and anomaly detection issues are associated with IoT systems in water quality monitoring. Therefore, this work proposes a prototype for a water quality monitoring system (IoT-WQMS) based on IoT technologies, which include in the system architecture a LoRa repeater and an anomaly detection algorithm. The system performs the data collection, data storage, anomaly detection, and alarm sending remotely and in real-time for the information to be captured by the multisensor node. The LoRa repeater allowed the spatial coverage of the LoRa communication to extend, making it possible to reach a place where originally there was no coverage with a single LoRa transmitter due to topography and line of sight. The prototype performed well in terms of packet loss rate, transmission time, and sensitivity, extending the long-range wireless communication distance. Indoor multinode testing validation for 29 days of the mean absolute error for average relative errors of water temperature, pH, turbidity, and total dissolved solids (TDS) were 0.65%, 0.30%, and 14.33%, respectively. The anomaly detector identified all erroneous data events due to node sensor recalibration and water recirculation pump failures. The IoT-WQMS increased the reliability of monitoring through the timely identification of any sensor malfunctions and extended the LoRa signal range, which are relevant features in the scope of in situ and real-time water quality monitoring.