ACAnthony Chow

Anthony Chow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anthony Chow has a total of 117 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Late Gadolinium Enhancement and Recovery of Left Ventricular Function After Catheter Ablation for Atrial Fibrillation

    by Sayed Al-Aidarous, Saffron Rajappan, Zhen Hua, Ayesha Ahmed, Rohan Patel, Christopher Patrick Uy, Matthew Webber, Mahmoud Elmowafy, Nikhil Ahluwalia, Sofiane Kouadria, et al.

    Lay Summary: Atrial fibrillation (AF) is an abnormal heart rhythm that can weaken the heart’s pumping function, resulting in heart failure. Catheter ablation is a procedure used to treat AF, in which thin tubes are passed through the blood vessels to the heart to target the areas responsible for the abnormal rhythm. In some patients with AF and heart failure, ablation can allow heart function to recover. However, it remains difficult to predict which patients will benefit most. Magnetic resonance imaging (MRI) of the heart can identify areas of damaged heart muscle, often referred to as scar or fibrosis. The pattern of scar is often used to help identify the cause of heart failure, and previous studies have shown that patients with scar are less likely to have improvement in heart function. In this study, we assessed 134 patients with AF and heart failure who underwent MRI before catheter ablation. We examined whether scar was present, its location and pattern, and how much of the heart muscle was affected. Overall, 101 patients had meaningful improvement in heart function after ablation. Patients who did not improve had approximately twice as much scar as those who did. Scar pattern or location did not predict recovery, but the amount of scar did. This suggests that clinicians should consider the amount of scar, rather than its presence or pattern alone, when estimating recovery after ablation. Even when MRI suggests another cause of heart failure, AF may still be contributing and patients may still benefit from ablation.

  • Open Access

    Improvement in cardiovascular function after atrial fibrillation ablation in heart failure: association with ECG and echocardiographic variables

    by Nikhil Ahluwalia, Shohreh Honarbakhsh, Vijay Shyam-Sundar, Abhishek Joshi, Hakam Abbass, Anthony Chow, Mehul Dhinoja, Ross J Hunter, Steffen Petersen, Guy Lloyd, et al.

  • Open Access

    Effect of scar distribution on transmural and planar repolarization gradients and dispersion in non-ischemic cardiomyopathies with ventricular arrhythmias

    by Johanna B Tonko, Eva Cabrera-Borrego, Pablo Sánchez-Millán, Juan Jiménez-Jáimez, Anthony Chow, Pier D Lambiase


  • Open Access

    Characterisation of patients who develop atrial fibrillation-induced cardiomyopathy

    by Nikhil Ahluwalia, Shohreh Honarbakhsh, Hakam Abbass, Abhishek Joshi, Anthony W C Chow, Mehul Dhinoja, Steffen Erhard Petersen, Ross J Hunter, Guy Lloyd, Richard J Schilling

    Introduction: Atrial fibrillation (AF)-induced cardiomyopathy (AIC) is retrospectively defined after normalisation of left ventricular ejection fraction (LVEF) in sinus rhythm. It is unclear why some patients develop AIC. Hypothesis: Patients with AIC have a subtle cardiomyopathic process that precedes their AF-mediated LVEF reduction. Detailed assessment of cardiac function after successful catheter ablation will reveal this. Objective: To evaluate the utility of measures to identify cardiomyopathic features that persist after LVEF normalisation in AIC. Methods: Patients with rate-controlled persistent AF and LVEF<50% undergoing catheter ablation (CA) were prospectively evaluated using echocardiography, cardio-pulmonary exercise testing and serum N-terminal pro b-type natriuretic peptide (NT-proBNP) at baseline and 6 months after CA. Participants with AIC, (LVEF recovery (≥50%) and no other cause for cardiac dysfunction) were evaluated using left ventricular (LV) longitudinal strain and left atrial (LA) reservoir strain (LARS). Changes in peak oxygen consumption and the minute ventilation/carbon dioxide production slope were measured as markers of functional capacity and ventilatory inefficiency. A control group of patients with persistent AF with preserved LVEF were also enrolled. Results: 34/41 (82.9%) participants recovered LVEF in sinus rhythm; defined as AIC. NT-proBNP levels were elevated in 18 (52.9%), and 16 reported ongoing heart failure (HF) symptoms. 10 (29.4%) had no improvement in functional capacity, and seven (20.6%) showed persistent ventilatory inefficiency. 20 (58.8%) had impaired global LV longitudinal strain with a relative apical sparing pattern. Nine (26.5%) had impaired LARS. There was an overlap of these abnormalities. 32 (94.1%) demonstrated at least one, 17 (50.0%) having no cardiovascular risk factors. Patients with preserved LVEF during persistent AF had similar demographics but a lower burden of short R-R intervals (<660 ms) on Holter monitoring. Discussion: Abnormal structural, metabolic and HF biomarkers are seen in patients with AIC in sinus rhythm. These features may represent a precedent subtle cardiomyopathic process predisposing them to left ventricular systolic dysfunction in AF. Trial registration number: NCT04987723.


  • Open Access

    High-density isochronal repolarization mapping and re-entry vulnerability estimation for scar-related ventricular tachycardia ablation: mechanistic basis, clinical application, and challenges

    by Johanna B Tonko, Anthony Chow, Pier D Lambiase

    Alterations in repolarization gradients and increased heterogeneity are key electrophysiological determinants of ventricular arrhythmogenesis across a variety of aetiologies with and without structural heart disease. High-density repolarization mapping to localize these repolarization abnormalities could improve characterization of the individual arrhythmogenic substrate and inform more targeted ablation. Yet, due to challenges posed by intrinsic features of human cardiac repolarization itself as well as technical and practical limitations, they are not routinely assessed, and traditional substrate mapping techniques remain strictly limited to determining conduction abnormalities. Here, we provide an overview of the mechanistic role of repolarization alterations in ventricular re-entry arrhythmias followed by a description of a clinical workflow that enables high-density repolarization mapping during ventricular tachycardia (VT) ablations using existing clinical tools. We describe step-by-step guidance of how-to set-up and generate repolarization maps illustrating the approach in case examples of structural normal and abnormal hearts. Furthermore, we discuss how repolarization mapping could be combined with existing substrate mapping approaches, including isochronal late activation mapping, to delineate sites of increased re-entry vulnerability, that may represent targets for ablation without the requirement for VT induction. Finally, we review challenges and pitfalls and ongoing controversies in relation to repolarization mapping and discuss the need for future technical and analytical improvements in repolarization mapping to integrate into ventricular substrate mapping strategies. Repolarization mapping remains investigational, and future research efforts need to be focused on prospective trials to establish the additional diagnostic value and its role in clinical ablation procedures.


  • Open Access

    Near-field detection and peak frequency metric for substrate and activation mapping of ventricular tachycardias in two- and three-dimensional circuits

    by Johanna B Tonko, Cristina Lozano, Javier Moreno, Anthony Chow, Mehul Dhinoja, Pier D Lambiase

    Successful ventricular arrhythmia (VA) ablation requires identification of functionally critical sites during contact mapping. Estimation of the peak frequency (PF) component of the electrogram (EGM) may improve correct near-field (NF) annotation to identify circuit segments on the mapped surface. In turn, assessment of NF and far-field (FF) EGMs may delineate the three-dimensional path of a ventricular tachycardia (VT) circuit. A proprietary NF detection algorithm was applied retrospectively to scar-related re-entry VT maps and compared with manually reviewed maps employing first deflection (FDcorr) for VT activation maps and last deflection (LD) for substrate maps. Ventricular tachycardia isthmus location and characteristics mapped with FDcorr vs. NF were compared. Omnipolar low-voltage areas, late activating areas, and deceleration zones (DZ) in LD vs. NF substrate maps were compared. On substrate maps, PF estimation was compared between isthmus and bystander sites. Activation mapping with entrainment and/or VT termination with radiofrequency (RF) ablation confirmed critical sites. Eighteen patients with high-density VT activation and substrate maps (55.6% ischaemic) were included. Near-field detection correctly located critical parts of the circuit in 77.7% of the cases compared with manually reviewed VT maps as reference. In substrate maps, NF detection identified deceleration zones in 88.8% of cases, which overlapped with FDcorr VT isthmus in 72.2% compared with 83.3% overlap of DZ assessed by LD. Applied to substrate maps, PF as a stand-alone feature did not differentiate VT isthmus sites from low-voltage bystander sites. Omnipolar voltage was significantly higher at isthmus sites with longer EGM durations compared with low-voltage bystander sites. The NF algorithm may enable rapid high-density activation mapping of VT circuits in the NF of the mapped surface. Integrated assessment and combined analysis of NF and FF EGM-components could support characterization of three-dimensional VT circuits with intramural segments. For scar-related substrate mapping, PF as a stand-alone EGM feature did not enable the differentiation of functionally critical sites of the dominant VT from low-voltage bystander sites in this cohort. Left top: LAT emphasis maps in VT activation mapping—Exemplary VT LAT maps with LAT-on-LAT emphasis in a RV VT and LV VT to highlight diastolic potentials. Left bottom: Example of left ventricular substrate map in a patient with extensive chronic anterior myocardial infarct (left, grey < 0.1 mV, purple > 1.5 mV) with emphasis on high-frequency EGMs (middle, emphasizing EGMs with >250 Hz) and visualization of peak frequency values (right, with nominal thresholds of EnSite X: grey < 200 Hz, white > 250 Hz). Right: Schematic illustration of how integration of NF and FF information may allow to distinguish two- and three-dimensional VT circuits and estimate the three-dimensional path of the VTCC. Yet, important confounders for using NF and peak frequency in ventricular mapping exist and need to be considered. 2D, two-dimensional; 3D, three-dimensional; EGM, electrogram; ICM, ischaemic cardiomyopathy; FF, far field; LV, left ventricle; NF, near field; RV, right ventricle; VT, ventricular tachycardia.


  • Open Access

    The BLISTER Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use

    by Maclean, Karishma Mahtani, Shohreh Honarbakhsh, Charles Butcher, Nikhil Ahluwalia, Adam S.C. Dennis, Antonio Creta, Malcolm Finlay, Mark Elliott, Vishal Mehta, et al.

    BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9–6.1]; P 50 mg/L (hazard ratio, 3.0 [95% CI, 1.4–6.4]; P =0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6–17.9]; P P =0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P =0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P =0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P =0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P =0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score ( https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection ) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


  • Open Access

    Exploiting SMART pass filter deactivation detection to minimize inappropriate subcutaneous implantable cardioverter defibrillator therapies: a real-world single-centre experience and management guide

    by Christopher Monkhouse, Amy Wharmby, Zoe Carter, Ross Hunter, Mehul Dhinoja, Anthony Chow, Antonio Creta, Shohreh Honarbakhsh, Syed Ahsan, Michele Orini, et al.

    Aims: The SMART Pass™ (SP) algorithm is a high-pass filter that aims to reduce inappropriate therapy (IT) in subcutaneous internal cardiac defibrillator (S-ICD), but SP can deactivate due to low amplitude sensed R waves or asystole. The association between IT and SP deactivation and management strategies were evaluated, hypothesizing SP deactivation increases the risk of IT and device re-programming, or lead/generator re-positioning could reduce this risk. Methods and results: Retrospective single-centre audit of Emblem™ S-ICD devices implanted 2016 to 2020 utilizing health records and remote monitoring data. Cox regression models evaluated associations between SP deactivation and IT. A total of 348 patients (27 ± 16.6 months follow-up) were studied: 73% primary prevention. Thirty-eight patients (11.8%) received 83 shocks with 27 patients (7.8%) receiving a total of 44 IT. Causes of IT were oversensing (98%) and aberrantly conducted atrial fibrillation (2%). SP deactivation occurred in 32 of 348 patients (9%) and was significantly associated with increased risk of IT (hazard ratio 5.36, 95% CI 2.37-12.13). SP deactivation was due to low amplitude R waves (94%), associated with a higher defibrillation threshold at implant and presence of arrhythmogenic right ventricular cardiomyopathy. No further IT occurred 16 ± 15.5 months after corrective interventions, with changing the sensing vector being successful in 59% of cases. Conclusion: To reduce the risk of IT, the cause of the SP deactivation should be investigated, and appropriate reprogramming, device, or lead modifications made. Utilizing the alert for SP deactivation and electrograms could pro-actively prevent IT.


  • Open Access

    Electrocardiographic imaging demonstrates electrical synchrony improvement by dynamic atrioventricular delays in patients with left bundle branch block and preserved atrioventricular conduction

    by Peter H Waddingham, Jan O Mangual, Michele Orini, Nima Badie, Amal Muthumala, Simon Sporton, Luke C McSpadden, Pier D Lambiase, Anthony W C Chow

    Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization. Dynamic atrioventricular delays targeting fusion with intrinsic conduction reduce electrical dyssynchrony.