Babar Hussain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Babar Hussain has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Aadil Rasool
Department of Bioresources, School of Biological Sciences, University of Kashmir 190006, Srinagar, India
1 shared publication Abdur Razaq Khan
Halcrow Pakistan (Pvt) Limited, Karachi, Pakistan
1 shared publicationAbeda Begum
Department of Environmental Science, Federal Urdu University of Arts
1 shared publication- Addy Wahyudie
Department of Electrical and Communication Engineering, United Arab Emirates University, Al Ain, United Arab Emirates
1 shared publication - Afrasiyab Khan
Department of Electrical Engineering, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
1 shared publication Afsheen Zehra
Department of Zoology, Faculty of Science, University of Karachi, Karachi, Pakistan
1 shared publication
Latest Publications
- Open Access
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 133510-133524
Stability Improvement of Renewable Energy Integrated Power Network Through Coordination of PSS, ISFCL, and STATCOM
Wind energy is a promising solution to meet growing global energy demands; however, its intermittent nature and low system inertia introduce significant challenges to power system stability. This paper addresses these issues by applying a coordinated deployment of a Power System Stabilizer (PSS), an Inductive Superconducting Fault Current Limiter (ISFCL), and a Static Synchronous Compensator (STATCOM) to the IEEE 9-bus system. Type 1 and Type 3 wind farms are integrated into the network, and system performance is evaluated using Sum of Mean Deviations (SMD) and Critical Clearing Time (CCT). The dual-input PSS enhances damping of rotor oscillations, ISFCL limits peak fault currents by up to 37%, and STATCOM, optimized using the Hooke & Jeeves method, reduces voltage dip by 0.3 pu and strengthens Low Voltage Ride Through (LVRT) capability. The combined deployment of all three devices restores the stability indices to levels comparable to those in the base case without wind integration. Among the two wind farm types, the coordinated application proves more effective for Type 3 wind farms, which show superior damping, reduced fault current, and enhanced voltage recovery, making them more suitable for reliable grid integration. Simulations were performed in PSCAD software.
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 133510-133524
Open AccessStability Improvement of Renewable Energy Integrated Power Network Through Coordination of PSS, ISFCL, and STATCOM
Wind energy is a promising solution to meet growing global energy demands; however, its intermittent nature and low system inertia introduce significant challenges to power system stability. This paper addresses these issues by applying a coordinated deployment of a Power System Stabilizer (PSS), an Inductive Superconducting Fault Current Limiter (ISFCL), and a Static Synchronous Compensator (STATCOM) to the IEEE 9-bus system. Type 1 and Type 3 wind farms are integrated into the network, and system performance is evaluated using Sum of Mean Deviations (SMD) and Critical Clearing Time (CCT). The dual-input PSS enhances damping of rotor oscillations, ISFCL limits peak fault currents by up to 37%, and STATCOM, optimized using the Hooke & Jeeves method, reduces voltage dip by 0.3 pu and strengthens Low Voltage Ride Through (LVRT) capability. The combined deployment of all three devices restores the stability indices to levels comparable to those in the base case without wind integration. Among the two wind farm types, the coordinated application proves more effective for Type 3 wind farms, which show superior damping, reduced fault current, and enhanced voltage recovery, making them more suitable for reliable grid integration. Simulations were performed in PSCAD software.
- Open Access
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 30832-30844
Stability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
The stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor fault current limiter (R-SFCL) and static synchronous compensator (STATCOM). The small signal (SS) stability of the test system is enhanced by selecting the best PSS type from the different types of PSS. An R-SFCL is used for improving the rotor angle and the frequency stability of the test system. Two indices, namely, transient stability index and sum of maximum deviations (SMD) index are introduced for determining the optimal locations of different sized R-SFCLs for increasing the rotor angle stability. The sensitivity index (SI) based on the power change between areas is applied for determining the optimal locations of different sized R-SFCLs for enhancing the frequency stability. Along with rotor angle and frequency stability, LVRT capability improvement of the wind farm using STATCOM is also considered. Finally, the combined effect of R-SFCL and STATCOM on the rotor angle and the frequency stability, for different fault locations, is also investigated for determining the optimal location of an R-SFCL in the presence of STATCOM. The results presented in the paper show that STATCOM affects both the number of feasible locations and the optimal locations that can be selected for different sized R-SFCLs for augmenting the rotor angle and the frequency stability of the system during faults. Moreover, it is pointed out that an optimal combination between the different sizes and the locations of R-SFCLs and STATCOM exists to enhance the overall stability of the test system under fault conditions.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 30832-30844
Open AccessStability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
The stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor fault current limiter (R-SFCL) and static synchronous compensator (STATCOM). The small signal (SS) stability of the test system is enhanced by selecting the best PSS type from the different types of PSS. An R-SFCL is used for improving the rotor angle and the frequency stability of the test system. Two indices, namely, transient stability index and sum of maximum deviations (SMD) index are introduced for determining the optimal locations of different sized R-SFCLs for increasing the rotor angle stability. The sensitivity index (SI) based on the power change between areas is applied for determining the optimal locations of different sized R-SFCLs for enhancing the frequency stability. Along with rotor angle and frequency stability, LVRT capability improvement of the wind farm using STATCOM is also considered. Finally, the combined effect of R-SFCL and STATCOM on the rotor angle and the frequency stability, for different fault locations, is also investigated for determining the optimal location of an R-SFCL in the presence of STATCOM. The results presented in the paper show that STATCOM affects both the number of feasible locations and the optimal locations that can be selected for different sized R-SFCLs for augmenting the rotor angle and the frequency stability of the system during faults. Moreover, it is pointed out that an optimal combination between the different sizes and the locations of R-SFCLs and STATCOM exists to enhance the overall stability of the test system under fault conditions.
- Open Access
- 28 December 2013
- Published by Enviro Research Publishers in Current World Environment
- Vol. 8 (3) , 395-402
Current Status of Mammals and Reptiles at Hub Dam Area, Sindh / Balochistan, Pakistan
- 28 December 2013
- Published by Enviro Research Publishers in Current World Environment
- Vol. 8 (3) , 395-402
Open AccessCurrent Status of Mammals and Reptiles at Hub Dam Area, Sindh / Balochistan, Pakistan