Sanghoon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sanghoon Lee has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Jang-Ung Park
Department of Materials Science and Engineering, Yonsei University
10 shared publications Enji Kim
Department of Materials Science and Engineering Yonsei University Seoul South Korea
5 shared publications- Inhea Jeong
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
5 shared publications Eunmin Kim
Department of Materials Science and Engineering Yonsei University Seoul South Korea
4 shared publications- Jakyoung Lee
Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea
4 shared publications Yeon-Mi Hong
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Wiley in Advanced Healthcare Materials
- p. e71933
Peri‐Infarct Cortical Network Remapping During Stroke Recovery via a Soft Liquid Metal Neural Interface
Stroke causes substantial reorganization of neural activity and connectivity in the peri‐infarct cortex during functional recovery. Tracking these changes at high resolution, however, remains difficult. Mechanical mismatch of conventional rigid neural probes is exacerbated in the fragile peri‐infarct region, destabilizing the tissue‐electrode interface and limiting long‐term recording. Here, we present a fully soft, liquid metal‐based multichannel neural interface that enables stable electrophysiological recording in freely moving mice. Using this platform, we performed longitudinal recordings before and after ischemic stroke, enabling within‐animal comparisons. We applied complementary analyses of population‐level latent dynamics and functional connectivity, capturing network‐level coordination and pairwise interactions. Both analyses revealed acute suppression followed by partial recovery without restoration of the pre‐stroke state. Instead, neural networks reorganized into a distinct and reproducible functional configuration. These findings establish soft liquid metal neural interfaces combined with population‐level analysis as a useful approach for resolving neural reorganization during stroke recovery.
- 29 October 2026
- Published by Wiley in Advanced Healthcare Materials
- p. e71933
Open AccessPeri‐Infarct Cortical Network Remapping During Stroke Recovery via a Soft Liquid Metal Neural Interface
Stroke causes substantial reorganization of neural activity and connectivity in the peri‐infarct cortex during functional recovery. Tracking these changes at high resolution, however, remains difficult. Mechanical mismatch of conventional rigid neural probes is exacerbated in the fragile peri‐infarct region, destabilizing the tissue‐electrode interface and limiting long‐term recording. Here, we present a fully soft, liquid metal‐based multichannel neural interface that enables stable electrophysiological recording in freely moving mice. Using this platform, we performed longitudinal recordings before and after ischemic stroke, enabling within‐animal comparisons. We applied complementary analyses of population‐level latent dynamics and functional connectivity, capturing network‐level coordination and pairwise interactions. Both analyses revealed acute suppression followed by partial recovery without restoration of the pre‐stroke state. Instead, neural networks reorganized into a distinct and reproducible functional configuration. These findings establish soft liquid metal neural interfaces combined with population‐level analysis as a useful approach for resolving neural reorganization during stroke recovery.
- Open Access
- 20 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8859
Neural dynamics of temporal interference stimulation monitoring by soft liquid metal interfaces across neural systems
- 20 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8859
Open AccessNeural dynamics of temporal interference stimulation monitoring by soft liquid metal interfaces across neural systems
- Open Access
- 16 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Horizons
- Vol. 11 (6) , 1536-1560
Emerging diverse 3D neural electrode architectures for bioelectronics
This review highlights recent advances in 3D neural electrodes, focusing on engineering methodologies that address the limitations of conventional neural interfaces by improving stability and enabling access to deeper biological regions.
- 16 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Horizons
- Vol. 11 (6) , 1536-1560
Open AccessEmerging diverse 3D neural electrode architectures for bioelectronics
This review highlights recent advances in 3D neural electrodes, focusing on engineering methodologies that address the limitations of conventional neural interfaces by improving stability and enabling access to deeper biological regions.
- Open Access
- 13 April 2026
- Published by Springer Nature in Nature Electronics
- Vol. 9 (5) , 569-580
An implantable epiretinal device for near-infrared light perception
Human vision relies on photoreceptor cells in the outer retina that are sensitive to visible light. However, many people suffer from blindness due to retinal diseases that cause photoreceptor degeneration. Electrical stimulation of retinal neurons can recreate the action potentials associated with seeing that are generated by these cells. Here we report a thin artificial retina that can be adhered to the epiretinal surface and can convert near-infrared (NIR) light into electrical stimuli that selectively stimulate ganglion cells. The artificial retina consists of a NIR-sensitive phototransistor array and three-dimensional liquid metal micropillar electrodes. The liquid metal electrodes enhance proximity to retinal ganglion cells, providing effective charge injection while minimizing tissue damage, owing to their low Young’s modulus. Ex vivo studies demonstrate its biocompatibility, and in vivo studies using healthy and blind mice demonstrate perception of both visible and NIR light, as indicated by cortical recordings and behavioural tests. The retina could, in the future, be used to create a NIR visual channel in patients with photoreceptor degenerative blindness without interfering with their remaining natural vision.
- 13 April 2026
- Published by Springer Nature in Nature Electronics
- Vol. 9 (5) , 569-580
Open AccessAn implantable epiretinal device for near-infrared light perception
Human vision relies on photoreceptor cells in the outer retina that are sensitive to visible light. However, many people suffer from blindness due to retinal diseases that cause photoreceptor degeneration. Electrical stimulation of retinal neurons can recreate the action potentials associated with seeing that are generated by these cells. Here we report a thin artificial retina that can be adhered to the epiretinal surface and can convert near-infrared (NIR) light into electrical stimuli that selectively stimulate ganglion cells. The artificial retina consists of a NIR-sensitive phototransistor array and three-dimensional liquid metal micropillar electrodes. The liquid metal electrodes enhance proximity to retinal ganglion cells, providing effective charge injection while minimizing tissue damage, owing to their low Young’s modulus. Ex vivo studies demonstrate its biocompatibility, and in vivo studies using healthy and blind mice demonstrate perception of both visible and NIR light, as indicated by cortical recordings and behavioural tests. The retina could, in the future, be used to create a NIR visual channel in patients with photoreceptor degenerative blindness without interfering with their remaining natural vision.
- 19 August 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4508-4541
Wearable and implantable microfluidic technologies for future digital therapeutics
Recent advances in wearable and implantable microfluidics enable real-time sensing, drug delivery, and closed-loop therapy, with emerging trends in stretchability, multimodal integration, and AI-driven data processing.
- 19 August 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4508-4541
Wearable and implantable microfluidic technologies for future digital therapeutics
Recent advances in wearable and implantable microfluidics enable real-time sensing, drug delivery, and closed-loop therapy, with emerging trends in stretchability, multimodal integration, and AI-driven data processing.
- Top Cited Papers
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (7) , 7337-7349
Implantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Stimulating large volumes of neural networks using macroelectrodes can modulate disorder-associated brain circuits effectively. However, conventional solid-metal electrodes often cause unwanted brain damage due to their high mechanical stiffness. In contrast, low-modulus liquid metals provide tissue-like stiffness while maintaining macroscale electrode dimensions. Here, we present implantable soft macroelectrodes made from biocompatible liquid metals for brain stimulation. These probes can be easily fabricated by simply filling polymeric tubes with a liquid metal, offering a straightforward method for creating brain stimulation devices. They can be customized in various lengths and diameters and also serve as recording microelectrodes. The electrode tips are enhanced with platinum nanoclusters, resulting in low impedance and effective charge injection while preventing liquid metal leakage into brain tissue. In vivo experiments in neuropathic pain rat models demonstrate the stability and effectiveness of these probes for simultaneous neural stimulation and recording, demonstrating their potential for pain alleviation and behavioral control.
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (7) , 7337-7349
Top Cited PapersImplantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Stimulating large volumes of neural networks using macroelectrodes can modulate disorder-associated brain circuits effectively. However, conventional solid-metal electrodes often cause unwanted brain damage due to their high mechanical stiffness. In contrast, low-modulus liquid metals provide tissue-like stiffness while maintaining macroscale electrode dimensions. Here, we present implantable soft macroelectrodes made from biocompatible liquid metals for brain stimulation. These probes can be easily fabricated by simply filling polymeric tubes with a liquid metal, offering a straightforward method for creating brain stimulation devices. They can be customized in various lengths and diameters and also serve as recording microelectrodes. The electrode tips are enhanced with platinum nanoclusters, resulting in low impedance and effective charge injection while preventing liquid metal leakage into brain tissue. In vivo experiments in neuropathic pain rat models demonstrate the stability and effectiveness of these probes for simultaneous neural stimulation and recording, demonstrating their potential for pain alleviation and behavioral control.
- Top Cited PapersOpen Access
- 27 February 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
In-vivo integration of soft neural probes through high-resolution printing of liquid electronics on the cranium
Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution printing of liquid metals forms soft neural probes with a cellular-scale diameter and adaptable lengths. Also, the printing of liquid metal-based circuits and interconnections along the curvature of the cranium enables the conformal integration of electronics to the body, and the cranial circuit delivers neural signals to a smartphone wirelessly. In the in-vivo studies using mice, the system demonstrates long-term recording (33 weeks) of neural activities in arbitrary brain regions. In T-maze behavioral tests, the system shows the behavior-induced activation of neurons in multiple brain regions.
- 27 February 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Top Cited PapersOpen AccessIn-vivo integration of soft neural probes through high-resolution printing of liquid electronics on the cranium
Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution printing of liquid metals forms soft neural probes with a cellular-scale diameter and adaptable lengths. Also, the printing of liquid metal-based circuits and interconnections along the curvature of the cranium enables the conformal integration of electronics to the body, and the cranial circuit delivers neural signals to a smartphone wirelessly. In the in-vivo studies using mice, the system demonstrates long-term recording (33 weeks) of neural activities in arbitrary brain regions. In T-maze behavioral tests, the system shows the behavior-induced activation of neurons in multiple brain regions.
- Top Cited PapersOpen Access
- 15 January 2024
- Published by Springer Nature in Nature Nanotechnology
- Vol. 19 (5) , 688-697
Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration
Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm−2) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.
- 15 January 2024
- Published by Springer Nature in Nature Nanotechnology
- Vol. 19 (5) , 688-697
Top Cited PapersOpen AccessLiquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration
Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm−2) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.
- Top Cited PapersOpen Access
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Top Cited PapersOpen AccessSmart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (4) , 1926-1946
Materials and Structural Designs for Neural Interfaces
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (4) , 1926-1946
Materials and Structural Designs for Neural Interfaces