Jinhao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jinhao Zhang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Changlin Han
Northwest Institute of Nuclear Energy Technology,Xi'an,China,710024
3 shared publications- Heng Zhou
Northwest Institute of Nuclear Energy Technology,Xian,China,710024
3 shared publications - Tingyong Jiang
Qianyuan National Laboratory 2 , Hangzhou 310024
3 shared publications - Zhen Liu
University of Minnesota
2 shared publications Baocheng Cai
School of Mechanical Engineering, Guangxi University, Nanning, China
1 shared publicationBo Jin
1 shared publication
Latest Publications
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6581-6588
A Calculation Method for the Optimal Initial Polar Distance of Capacitive Force Sensors
For capacitive sensors, the initial polar distance of capacitors has a vital influence on performances of capacitive sensors, however, there are few current studies on the method of calculating the initial polar distance of capacitors, leading to a lack of corresponding theoretical basis for the design of capacitive sensors. In this paper, a calculation method for the optimal initial polar distance based on minimum error is proposed. The total error expression is derived from error analysis, which clarifies the complex relationship between the total error and the initial polar distance, and the optimal initial polar distance is solved by the Newton’s method. A capacitive torque sensor is used in the experiment to verify the calculation method for the optimal initial polar distance, the theoretical error and experimental error of the sensor are compared, and the results show that the experimental error is consistent with the theoretical error curve. The optimal initial polar distance obtained by the calculation method is 0.8479 mm, which is within the range of 0.8 mm - 0.9 mm determined by the experiment. The theoretical minimum total error is 0.211% and the experimental minimum total error is 0.208%. The total error expression proposed in this paper is accurate, and the calculation method of the initial polar distance is effective. In addition, theoretical analysis reveals that the differential parallel plate capacitor has the characteristic that any small deformation of the moving plate can be equivalent to a translation whose magnitude is the mean value of the deformation.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6581-6588
A Calculation Method for the Optimal Initial Polar Distance of Capacitive Force Sensors
For capacitive sensors, the initial polar distance of capacitors has a vital influence on performances of capacitive sensors, however, there are few current studies on the method of calculating the initial polar distance of capacitors, leading to a lack of corresponding theoretical basis for the design of capacitive sensors. In this paper, a calculation method for the optimal initial polar distance based on minimum error is proposed. The total error expression is derived from error analysis, which clarifies the complex relationship between the total error and the initial polar distance, and the optimal initial polar distance is solved by the Newton’s method. A capacitive torque sensor is used in the experiment to verify the calculation method for the optimal initial polar distance, the theoretical error and experimental error of the sensor are compared, and the results show that the experimental error is consistent with the theoretical error curve. The optimal initial polar distance obtained by the calculation method is 0.8479 mm, which is within the range of 0.8 mm - 0.9 mm determined by the experiment. The theoretical minimum total error is 0.211% and the experimental minimum total error is 0.208%. The total error expression proposed in this paper is accurate, and the calculation method of the initial polar distance is effective. In addition, theoretical analysis reveals that the differential parallel plate capacitor has the characteristic that any small deformation of the moving plate can be equivalent to a translation whose magnitude is the mean value of the deformation.
- 25 October 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 453, 139762
Hydrogen bond and 3D frameworks to reconcile the conflict between safety and detonation performance in energetic metal–organic frameworks
- 25 October 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 453, 139762
Hydrogen bond and 3D frameworks to reconcile the conflict between safety and detonation performance in energetic metal–organic frameworks
- 28 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. ume1, 1-3
Multilayer equivalent medium method for conical lossy medium
Based on the S-parameter inversion method, the equivalent dielectric constant model of single-layer lossy medium is established by obtaining the relationship between area ratio and equivalent dielectric constant in the case of single-layer. Then the conical lossy medium is treated as a layered impedance model. Through cascade and combined with the input impedance of the transmission line, the reflection level of the conical lossy medium is basically consistent with the full wave simulation results.
- 28 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. ume1, 1-3
Multilayer equivalent medium method for conical lossy medium
Based on the S-parameter inversion method, the equivalent dielectric constant model of single-layer lossy medium is established by obtaining the relationship between area ratio and equivalent dielectric constant in the case of single-layer. Then the conical lossy medium is treated as a layered impedance model. Through cascade and combined with the input impedance of the transmission line, the reflection level of the conical lossy medium is basically consistent with the full wave simulation results.
- 28 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. ume1, 1-2
A double helix coaxial pulse compression structure
Based on simultaneous interpreting of double coaxial structures, the middle cylinder is designed as a helical structure in order to achieve longer output pulse under the same transmission line length. The full wave simulation shows that the pulse width can be effectively increased by increasing the number of middle cylinder spirals, but too many middle cylinder spirals will lead to the deterioration of waveform flat top. Based on the reasonable selection of the spiral number of the middle cylinder, the waveform shaping can be realized by further adjusting the spiral number of the inner cylinder.
- 28 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. ume1, 1-2
A double helix coaxial pulse compression structure
Based on simultaneous interpreting of double coaxial structures, the middle cylinder is designed as a helical structure in order to achieve longer output pulse under the same transmission line length. The full wave simulation shows that the pulse width can be effectively increased by increasing the number of middle cylinder spirals, but too many middle cylinder spirals will lead to the deterioration of waveform flat top. Based on the reasonable selection of the spiral number of the middle cylinder, the waveform shaping can be realized by further adjusting the spiral number of the inner cylinder.
- 28 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Calculation of Material Permittivity and Permeability Based on Trust Region Algorithm
The permittivity and permeability are important parameters to characterize the electromagnetic characteristics of materials. In order to solve the problem of the limitation of material processing shape and accuracy in the calculation, this paper proposes a method to calculate the complex permittivity and permeability of materials by using CST simulation, trust region algorithm and measured S parameters based on rectangular waveguide method (one of transmission/reflection method). In this paper, the performance of four common CST optimization algorithms in this problem is compared, and the effectiveness of the method is verified by using PTFE material.
- 28 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Calculation of Material Permittivity and Permeability Based on Trust Region Algorithm
The permittivity and permeability are important parameters to characterize the electromagnetic characteristics of materials. In order to solve the problem of the limitation of material processing shape and accuracy in the calculation, this paper proposes a method to calculate the complex permittivity and permeability of materials by using CST simulation, trust region algorithm and measured S parameters based on rectangular waveguide method (one of transmission/reflection method). In this paper, the performance of four common CST optimization algorithms in this problem is compared, and the effectiveness of the method is verified by using PTFE material.
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 687 (1) , 012045
Study on formation mechanism of ground fissures induced by underground engineering construction in Chongqing area
The geological structure of Chongqing area is complex, many small and mediumsized faults are developed in the axis of anticline fold, and there are many structural fissures in rock strata, and karst landform is developed in some areas. With the development of economy, the construction of underground engineering is increasing, which leads to the rapid decline of groundwater and construction vibration, resulting in a large number of uneven ground settlement, and the formation of ground fissures. This paper introduces the various forms of ground fissures, analyzes the formation process of uneven ground settlement area in the process of underground engineering construction, establishes the stress model of soil surface cracks based on the fracture mechanics theory of cohesive soil cracks, uses the fracture judgment of I-II composite cracks to determine whether the cracks expand or not, and uses the formula of soil cracking angle to calculate its propagation direction, and preliminarily explains the fracture mechanism of soil in the ground fissure area. It provides reference for the further study of corresponding disaster mechanism.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 687 (1) , 012045
Open AccessStudy on formation mechanism of ground fissures induced by underground engineering construction in Chongqing area
The geological structure of Chongqing area is complex, many small and mediumsized faults are developed in the axis of anticline fold, and there are many structural fissures in rock strata, and karst landform is developed in some areas. With the development of economy, the construction of underground engineering is increasing, which leads to the rapid decline of groundwater and construction vibration, resulting in a large number of uneven ground settlement, and the formation of ground fissures. This paper introduces the various forms of ground fissures, analyzes the formation process of uneven ground settlement area in the process of underground engineering construction, establishes the stress model of soil surface cracks based on the fracture mechanics theory of cohesive soil cracks, uses the fracture judgment of I-II composite cracks to determine whether the cracks expand or not, and uses the formula of soil cracking angle to calculate its propagation direction, and preliminarily explains the fracture mechanism of soil in the ground fissure area. It provides reference for the further study of corresponding disaster mechanism.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 284-289
MEAK-MCS: Metamodel Error Measure Function based Active Learning Kriging with Monte Carlo Simulation for Reliability Analysis
The active learning reliability analysis method combining Kriging and MCS, termed as AK-MCS, has received great attention over the past few years. When the limit-state function is replaced by Kriging metamodel, the estimation of failure probability will be influenced by metamodel error. In this paper, an error measure function is developed to quantify the influence of metamodel error. Then, it is introduced in the termination conditions of Kriging update in AK-MCS. A metamodel error measure function based AK-MCS (MEAK-MCS) method is finally proposed. With the error measure function, the update of Kriging can be efficiently terminated. Numerical examples are presented to test the efficiency and accuracy of MEAK-MCS. Results indicate that MEAK-MCS can more efficiently estimate the failure probability than AK-MCS and has similar accuracy with AK-MCS.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 284-289
MEAK-MCS: Metamodel Error Measure Function based Active Learning Kriging with Monte Carlo Simulation for Reliability Analysis
The active learning reliability analysis method combining Kriging and MCS, termed as AK-MCS, has received great attention over the past few years. When the limit-state function is replaced by Kriging metamodel, the estimation of failure probability will be influenced by metamodel error. In this paper, an error measure function is developed to quantify the influence of metamodel error. Then, it is introduced in the termination conditions of Kriging update in AK-MCS. A metamodel error measure function based AK-MCS (MEAK-MCS) method is finally proposed. With the error measure function, the update of Kriging can be efficiently terminated. Numerical examples are presented to test the efficiency and accuracy of MEAK-MCS. Results indicate that MEAK-MCS can more efficiently estimate the failure probability than AK-MCS and has similar accuracy with AK-MCS.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 95-100
Modeling and Control of New Wind Power Grid Connected System
With the rapid development of smart grid, flexible access of distributed power supply has become one of the important development goals on smart grid construction. A new wind power grid connected topology based on solid state transformer (SST) is proposed in this paper, the topological structure makes wind power system connect with the power grid through the solid state transformer, the use of solid state transformer can realize electrical isolation between the fan and the power grid and compensate reactive power to system in the situation of non additional reactive power compensation device. Adding unloading units to consume excess energy in the DC side, which makes the system have low voltage operation ability. This paper has built permanent magnet synchronous generator (PMSG) wind power generation system on the core circuit of solid state transformer based on PSCAD/EMTDC, simulation results verify the feasibility of the topology structure and control strategy.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 95-100
Modeling and Control of New Wind Power Grid Connected System
With the rapid development of smart grid, flexible access of distributed power supply has become one of the important development goals on smart grid construction. A new wind power grid connected topology based on solid state transformer (SST) is proposed in this paper, the topological structure makes wind power system connect with the power grid through the solid state transformer, the use of solid state transformer can realize electrical isolation between the fan and the power grid and compensate reactive power to system in the situation of non additional reactive power compensation device. Adding unloading units to consume excess energy in the DC side, which makes the system have low voltage operation ability. This paper has built permanent magnet synchronous generator (PMSG) wind power generation system on the core circuit of solid state transformer based on PSCAD/EMTDC, simulation results verify the feasibility of the topology structure and control strategy.