Shuai Nie
Research Subjects
Shuai Nie has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Jing Li
5 shared publicationsYunxia He
School of Materials and Metallurgy
5 shared publicationsXitao Yin
3 shared publications- Davoud Dastan
Cornell University
2 shared publications - Lin Tao
Key Laboratory of Energy Materials and Electrochemistry Research Liaoning Province, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China
2 shared publications Preeyaporn Poldorn
Center for Organic Electronic and Alternative Energy, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
2 shared publications
Latest Publications
- 23 May 2025
- Published by Elsevier in Surfaces and Interfaces
- Vol. 69
Tailoring selectivity in graphene-based co2 reduction catalysts: A first-principles study
- 23 May 2025
- Published by Elsevier in Surfaces and Interfaces
- Vol. 69
Tailoring selectivity in graphene-based co2 reduction catalysts: A first-principles study
- 1 December 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (12) , 6390-6399
Insights into Selective Sensitivity of In2O3-CuO Heterojunction Nanocrystals to CH4 over CO and H2: Experiments and First-Principles Calculations
Metal oxide semiconductor gas sensors have demonstrated exceptional potential in gas detection due to their high sensitivity, rapid response time, and impressive selectivity for identifying various sorts of gases. However, selectively distinguishing CH4 from those of CO and H2 remains a significant challenge. This difficulty primarily stems from the weakly reducing nature of CH4, which results in a low adsorption response and makes it prone to interference from stronger reducing gases in the surroundings. Herein, we synthesized In2O3-xCuO nanocomposites using a hydrothermal method to explore their gas sensing properties toward CH4, CO, and H2. Characterization tests confirmed the successful preparation of In2O3-xCuO nanocomposites with different In:Cu molar ratios and the formation of a p-n heterojunction. The gas sensing test results indicated that the In2O3-2.1CuO nanocomposites calcined at 500 °C and measured at 350 °C displayed a p-type response for CH4 and an n-type response for CO and H2, allowing for accurate differentiation of CH4 from CO and H2. Moreover, the In2O3-2.1CuO sensor also showed excellent stability and reproducibility across all three gases. First-principles calculations revealed distinct changes in the electronic structure of the In2O3-CuO heterojunction upon adsorption of CH4, CO, and H2, a finding that aligns with empirical evidence. The gas selectivity mechanism was effectively explained by variations in the energy band gap, driven by electrical behavior during the adsorption process. This work suggests a promising approach for developing selective gas sensors capable of detecting weakly reducing gases.
- 1 December 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (12) , 6390-6399
Insights into Selective Sensitivity of In2O3-CuO Heterojunction Nanocrystals to CH4 over CO and H2: Experiments and First-Principles Calculations
Metal oxide semiconductor gas sensors have demonstrated exceptional potential in gas detection due to their high sensitivity, rapid response time, and impressive selectivity for identifying various sorts of gases. However, selectively distinguishing CH4 from those of CO and H2 remains a significant challenge. This difficulty primarily stems from the weakly reducing nature of CH4, which results in a low adsorption response and makes it prone to interference from stronger reducing gases in the surroundings. Herein, we synthesized In2O3-xCuO nanocomposites using a hydrothermal method to explore their gas sensing properties toward CH4, CO, and H2. Characterization tests confirmed the successful preparation of In2O3-xCuO nanocomposites with different In:Cu molar ratios and the formation of a p-n heterojunction. The gas sensing test results indicated that the In2O3-2.1CuO nanocomposites calcined at 500 °C and measured at 350 °C displayed a p-type response for CH4 and an n-type response for CO and H2, allowing for accurate differentiation of CH4 from CO and H2. Moreover, the In2O3-2.1CuO sensor also showed excellent stability and reproducibility across all three gases. First-principles calculations revealed distinct changes in the electronic structure of the In2O3-CuO heterojunction upon adsorption of CH4, CO, and H2, a finding that aligns with empirical evidence. The gas selectivity mechanism was effectively explained by variations in the energy band gap, driven by electrical behavior during the adsorption process. This work suggests a promising approach for developing selective gas sensors capable of detecting weakly reducing gases.
- 31 July 2024
- Published by Elsevier in Ceramics International
- Vol. 50 (21) , 41397-41406
Selective adsorption behavior of reducing gases on the NiO–In2O3 heterojunction under the interfacial effect
- 31 July 2024
- Published by Elsevier in Ceramics International
- Vol. 50 (21) , 41397-41406
Selective adsorption behavior of reducing gases on the NiO–In2O3 heterojunction under the interfacial effect
- 3 November 2023
- Published by Elsevier in Applied Surface Science
- Vol. 644
A single response to reducing gases by NiO-TiO2 heterojunction nanocrystals
- 3 November 2023
- Published by Elsevier in Applied Surface Science
- Vol. 644
A single response to reducing gases by NiO-TiO2 heterojunction nanocrystals
- 24 October 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (11) , 4121-4131
Insights into Selective Mechanism of NiO-TiO2 Heterojunction to H2 and CO
The construction of p-n heterojunctions has become a widely adopted strategy for achieving the selective detection of reducing gases, including H2 and CO. Nevertheless, the elucidation of the gas selectivity mechanism at the nanoscale remains elusive. First-principle calculations provide an attractive avenue for comprehending the influence of coordination structures on gas-sensitive selectivity, thereby unveiling the structure-activity relationship of p-n heterojunction sites. In this study, we investigate the selective adsorption behavior of H2 and CO on a NiO-TiO2 heterojunction using density functional theory. The results of d-band center analysis confirm that the NiO-TiO2 heterojunction with adsorbed oxygen significantly enhances the adsorption stability of reducing gases. Intriguingly, our calculations reveal that H2 has a higher affinity for adsorbed oxygen on the heterojunction surface compared to that of CO, corresponding to a lower H2 adsorption energy. Density of states (DOS) results indicate that the NiO-TiO2 heterojunction, with preadsorbed oxygen, exhibits ultrahigh selectivity with an n-type gas-sensitive response to H2, effectively eliminating the cross-sensitivity observed with CO, as confirmed by gas-sensitive characterization research. The sensing mechanism of the NiO-TiO2 heterojunction's selective detection of H2 without interference from CO can be visually explained by electron transfer and potential barrier changes, paving the way for future developments in novel, selective gas-sensitive materials.
- 24 October 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (11) , 4121-4131
Insights into Selective Mechanism of NiO-TiO2 Heterojunction to H2 and CO
The construction of p-n heterojunctions has become a widely adopted strategy for achieving the selective detection of reducing gases, including H2 and CO. Nevertheless, the elucidation of the gas selectivity mechanism at the nanoscale remains elusive. First-principle calculations provide an attractive avenue for comprehending the influence of coordination structures on gas-sensitive selectivity, thereby unveiling the structure-activity relationship of p-n heterojunction sites. In this study, we investigate the selective adsorption behavior of H2 and CO on a NiO-TiO2 heterojunction using density functional theory. The results of d-band center analysis confirm that the NiO-TiO2 heterojunction with adsorbed oxygen significantly enhances the adsorption stability of reducing gases. Intriguingly, our calculations reveal that H2 has a higher affinity for adsorbed oxygen on the heterojunction surface compared to that of CO, corresponding to a lower H2 adsorption energy. Density of states (DOS) results indicate that the NiO-TiO2 heterojunction, with preadsorbed oxygen, exhibits ultrahigh selectivity with an n-type gas-sensitive response to H2, effectively eliminating the cross-sensitivity observed with CO, as confirmed by gas-sensitive characterization research. The sensing mechanism of the NiO-TiO2 heterojunction's selective detection of H2 without interference from CO can be visually explained by electron transfer and potential barrier changes, paving the way for future developments in novel, selective gas-sensitive materials.
- 3 April 2023
- Published by Elsevier in Materials Today Nano
- Vol. 22
Atomic-level insights into selective adsorption of H2 and CO on SnO2/CoO heterojunctions
- 3 April 2023
- Published by Elsevier in Materials Today Nano
- Vol. 22
Atomic-level insights into selective adsorption of H2 and CO on SnO2/CoO heterojunctions
- Open Access
- 23 August 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (19) , 9272-9280
Multiplexed Salivary Protein Profiling for Patients with Respiratory Diseases Using Fiber-Optic Bundles and Fluorescent Antibody-Based Microarrays
Over the past 40 years, the incidence and prevalence of respiratory diseases have increased significantly throughout the world, damaging economic productivity and challenging health care systems. Current diagnoses of different respiratory diseases generally involve invasive sampling methods such as induced sputum or bronchoalveolar lavage that are uncomfortable, or even painful, for the patient. In this paper, we present a platform incorporating fiber-optic bundles and antibody-based microarrays to perform multiplexed protein profiling of a panel of six salivary biomarkers for asthma and cystic fibrosis (CF) diagnosis. The platform utilizes an optical fiber bundle containing approximately 50 000 individual 4.5 μm diameter fibers that are chemically etched to create microwells in which modified microspheres decorated with monoclonal capture antibodies can be deposited. On the basis of a sandwich immunoassay format, the array quantifies human vascular endothelial growth factor (VEGF), interferon gamma-induced protein 10 (IP-10), interleukin-8 (IL-8), epidermal growth factor (EGF), matrix metalloproteinase 9 (MMP-9), and interleukin-1 beta (IL-1β) salivary biomarkers in the subpicomolar range. Saliva supernatants collected from 291 individuals (164 asthmatics, 71 CF patients, and 56 healthy controls (HC)) were analyzed on the platform to profile each group of patients using this six-analyte suite. It was found that four of the six proteins were observed to be significantly elevated (p < 0.01) in asthma and CF patients compared with HC. These results demonstrate the potential to use the multiplexed protein array platform for respiratory disease diagnosis.
- 23 August 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (19) , 9272-9280
Open AccessMultiplexed Salivary Protein Profiling for Patients with Respiratory Diseases Using Fiber-Optic Bundles and Fluorescent Antibody-Based Microarrays
Over the past 40 years, the incidence and prevalence of respiratory diseases have increased significantly throughout the world, damaging economic productivity and challenging health care systems. Current diagnoses of different respiratory diseases generally involve invasive sampling methods such as induced sputum or bronchoalveolar lavage that are uncomfortable, or even painful, for the patient. In this paper, we present a platform incorporating fiber-optic bundles and antibody-based microarrays to perform multiplexed protein profiling of a panel of six salivary biomarkers for asthma and cystic fibrosis (CF) diagnosis. The platform utilizes an optical fiber bundle containing approximately 50 000 individual 4.5 μm diameter fibers that are chemically etched to create microwells in which modified microspheres decorated with monoclonal capture antibodies can be deposited. On the basis of a sandwich immunoassay format, the array quantifies human vascular endothelial growth factor (VEGF), interferon gamma-induced protein 10 (IP-10), interleukin-8 (IL-8), epidermal growth factor (EGF), matrix metalloproteinase 9 (MMP-9), and interleukin-1 beta (IL-1β) salivary biomarkers in the subpicomolar range. Saliva supernatants collected from 291 individuals (164 asthmatics, 71 CF patients, and 56 healthy controls (HC)) were analyzed on the platform to profile each group of patients using this six-analyte suite. It was found that four of the six proteins were observed to be significantly elevated (p < 0.01) in asthma and CF patients compared with HC. These results demonstrate the potential to use the multiplexed protein array platform for respiratory disease diagnosis.