BLBertrand Lecordier

Bertrand Lecordier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bertrand Lecordier has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental investigation of turbulent soot transport in buoyant vertical wall fires using simultaneous LII–PIV

    by Andres Valencia, Bertrand Lecordier, David Morrisset, Martine Talbaut, Alexis Coppalle

    Buoyant wall-attached flames are common configurations in façade and rack-storage fires, where wall confinement and buoyancy govern turbulence, mixing, and radiative heat transfer. In these flows, soot dominates radiation and participates in coupled turbulent-chemical transport processes. Despite its importance, experimentally resolved turbulent soot transport in wall fires remains largely undocumented. In this study, turbulent soot transport in a steady buoyant vertical wall fire is quantified using simultaneous planar Laser-Induced Incandescence (LII) and Particle Image Velocimetry (PIV). A 40 cm porous burner supplied with a methane-ethylene mixture was used to generate a steady buoyant wall-attached flame under quiescent conditions. Time-resolved 2D fields of soot volume fraction and velocity were obtained over a 14 × 4 cm region, spanning the laminar-to-turbulent regime. Soot formed intermittent sheet-like structures with characteristic transverse scales of 2 to 3 cm. Vertical velocities increased from approximately 1 m s⁻¹ to over 4 m s⁻¹ with height, while cross-stream velocities reached order 1 m s⁻¹, producing significant instantaneous lateral soot transport. Direct evaluation of correlated soot-velocity fluctuations showed three wall-normal transport regions: (I) a near-wall zone dominated by mean buoyant convection with negligible turbulent soot flux; (II) an intermediate region where turbulent soot transport peaked and was displaced from the maximum mean soot concentration; and (III) an outer mixing region where soot flux decayed despite sustained Reynolds shear stress due to dilution and oxidation. These measurements provide resolved turbulent soot flux data for modelling soot-turbulence interactions in wall-adjacent fire scenarios.

  • Open Access

    On the limits of stability of CO2 diluted turbulent oxyflames for CCUS applications

    by Laura Pirateque Henao, Bertrand Lecordier, Corine Lacour, Armelle Cessou, David Honore

  • Electrohydrodynamic deformation and oscillatory dynamics of a neutrally buoyant droplet

    by S. Sharma, B. Lecordier, M. S. Shadloo

    This study investigates the electrohydrodynamic deformation of dielectric liquid droplet exposed to a uniform electric field. Experiments are performed using a two-phase system comprising a silicone oil droplet dispersed in castor oil as the bulk. The droplet behaviors, including deformation, flattening, oscillation, and rotation, are analyzed across a range of electric field strengths using shadow imaging technique. For electric field strengths ranging from Eo = 4.5 to 5.75 kV/cm, the silicone oil droplet initially deforms into an oblate shape, with their axes tilting relative to the direction of the applied field. At lower field intensities, i.e., Eo<4.75 kV/cm, the droplet deformation and tilt/orientation remain steady; however, at higher electric field strengths, the droplets display oscillatory behavior characterized by periodic tilting and deformation dynamics. The results reveal distinct regimes of droplet deformation governed by electrohydrodynamic instabilities, where the induced electric torque causes the droplet axis to deviate from the field direction before relaxing into a transiently stable configuration. This study identifies the transitions of droplet response from a monotonic deformation at low field intensity to non-monotonic oscillatory deformation behavior at higher fields, determined by the dielectric contrast and fluid properties of the two phases. These insights enhance the current understanding of droplet dynamics in electric fields and hold relevance for technologies such as inkjet printing, microfluidics, electro-coalescence, and phase separation processes.


  • Electrohydrodynamic flows inside a neutrally buoyant leaky dielectric drop

    by Joel R. Karp, Bertrand Lecordier, Mostafa S. Shadloo

    We present an experimental investigation of electrohydrodynamic (EHD) flows within a neutrally buoyant drop with a radius of 2.25 mm. Utilizing particle image velocimetry and high-speed shadowgraphy, we measure the internal circulation and reported velocity profiles in the bulk and at the interface of the drop. Two leaky dielectric liquids, silicone and castor oils, are employed as the drop and as the external phase, allowing the analysis of two shape configurations: oblate and prolate. The strength of the applied uniform electric field (from 0.125 to 1.75 kV/cm) enables the analysis covering both the small-deformation limit (CaE≪1) and drops with larger deformations. Our measurements show good agreement with the leaky dielectric model (LDM) for the small-deformation cases. The flows begin at the interface as a result of jump in the electric stresses, leading then to four counter-rotating vortices inside the drop. At a permanent regime, the analytical solutions adequately predict the radial and tangential velocity components within the drop. However, a nuanced behavior is noticed for larger deformations, where the LDM theory underpredicts the internal circulation. Moreover, due to the increased deformation, a non-uniform azimuthal profile is observed for the velocity at the interface, vθ. Transient measurements of this velocity component enlighten the dynamic response of the EHD flows of the drop. Following the available analytical solutions, the dynamic response is governed by the timescale of the deformation of the drop, τdef=μa/γ. We propose a critical value of CaE≈0.1 below which the LDM adequately describes the velocity field in both quasi steady-state and transitory regimes.


  • 10.1063/5.0142921.2

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.

  • 10.1063/5.0142921.4

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.

  • Open Access

    10.1063/5.0142921.5

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.

  • 10.1063/5.0142921.6

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.

  • 10.1063/5.0142921.1

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.

  • Open Access

    10.1063/5.0142921.3

    by Franck Lefebvre, Carole Gobin, Gilles Godard, Corine Lacour, Bertrand Lecordier, Armelle Cessou

    We examined the effect of hydrogen (H2) enrichment on the primary fuel methane (CH4) in a canonical non-premixed bluff-body stabilized burner operating under typical central jet-dominated flame mode. In the chosen mode of operation, globally, the flow field and flame feature three important successive spatial zones: the recirculation zone, the neck zone, and the jet-like flame zone. The flame is exposed to a higher stretch rate in the neck zone in such a configuration and eventually undergoes local extinction. Such local extinction and subsequent re-ignition/reconnection of broken flame branches have substantial implications for the hydrodynamic instability of the coaxial annular air shear layer. It is well known that H2 addition increases the flame extinction strain rate ( κext) and thus alters the local extinction phenomenon. To understand this, we performed experiments at 0%, 10%, 20%, 30%, 50%, 80%, and 100% hydrogen proportion in the H2-CH4 blend. High repetition rate (5 kHz) Particle Image Velocimetry and OH Planar Laser Induced Fluorescence (PLIF) measurements are simultaneously implemented to gain quantitative insight into the flow field and flame structure. A detailed analysis performed over the instantaneous OH–PLIF datasets reveals the absence of local extinctions in flames with H2 enrichment >30% due to an increased extinction strain rate ( κext). Furthermore, it is found that H2 enrichment plays a significant role in the reconnection/re-ignition of the broken flame branches formed during the local extinction. For instance, a high reconnection probability is observed in flames with an H2 addition of ≥20%. Consequently, variations in the mean reaction zone height are witnessed for different H2 enrichment levels. Further analysis of the influence of variation in reaction zone height on flow field hydrodynamics is explored using Proper Orthogonal Decomposition (POD) and Continuous Wavelet Transform (CWT). The results obtained from POD and CWT indicated the suppression of vortex shedding at the annular air shear layer for H2 addition greater than 20% and irregular wrinkling of flame fronts. Thus, they quantified the beneficial effect of H2 addition in turbulent flame stabilization.