Wenhui Zeng
Research Subjects
Wenhui Zeng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chunsheng Guo
School of Electrical Engineering, Sichuan University, Chengdu, China
1 shared publication - Jianquan Liao
College of Electrical Engineering, Sichuan University, Chengdu 610065, China
1 shared publication - Ting Li
State Grid Sichuan Economic Research Institute, Chengdu 610095, China
1 shared publication - Yangfan Cheng
College of Electrical Engineering, Sichuan University, Chengdu 610065, China
1 shared publication - Yuhong Wang
College of Electrical Engineering, Sichuan University, Chengdu 610065, China
1 shared publication - Yuqi Han
State Grid Sichuan Economic Research Institute, Chengdu 610095, China
1 shared publication
Latest Publications
- Open Access
- 7 April 2023
- Published by MDPI AG in Electronics
- Vol. 12 (8) , 1764
Fault Detection and Zonal Protection Strategy of Multi-Voltage Level DC Grid Based on Fault Traveling Wave Characteristic Extraction
Currently, DC breakers are commonly used in mainstream protection schemes for DC grids to eliminate faults. However, the cost of high voltage DC (HVDC) breakers is high, and equipping each DC line with DC breakers is expensive. In order to minimize the number of DC breakers while ensuring the reliability of the power supply, a zonal protection strategy suitable for multi-voltage level DC grids is proposed. Subsequently, the qualitative impact of partial power interruption caused by fault DC areas is analyzed in the system. The basic zonal principle of the multi-voltage level DC grid is formulated, taking into account unbalanced power, the mode of system-level control, and the type of converters. Additionally, a time sequence coordination strategy is derived in detail based on the characteristics of DC breakers, AC/DC converters, DC/DC converters, AC breakers, high-speed switches, and other fault removal components. Finally, a seven-terminal DC grid is modeled in the PSCAD/EMTDC simulation platform. According to the simulation analysis, the DC grid can adopt the converter with fault clearing ability or an AC circuit breaker to cooperate with the fast disconnector (FD) to complete fault clearing in the DC fault area under the proposed zonal protection coordination strategy.
- 7 April 2023
- Published by MDPI AG in Electronics
- Vol. 12 (8) , 1764
Open AccessFault Detection and Zonal Protection Strategy of Multi-Voltage Level DC Grid Based on Fault Traveling Wave Characteristic Extraction
Currently, DC breakers are commonly used in mainstream protection schemes for DC grids to eliminate faults. However, the cost of high voltage DC (HVDC) breakers is high, and equipping each DC line with DC breakers is expensive. In order to minimize the number of DC breakers while ensuring the reliability of the power supply, a zonal protection strategy suitable for multi-voltage level DC grids is proposed. Subsequently, the qualitative impact of partial power interruption caused by fault DC areas is analyzed in the system. The basic zonal principle of the multi-voltage level DC grid is formulated, taking into account unbalanced power, the mode of system-level control, and the type of converters. Additionally, a time sequence coordination strategy is derived in detail based on the characteristics of DC breakers, AC/DC converters, DC/DC converters, AC breakers, high-speed switches, and other fault removal components. Finally, a seven-terminal DC grid is modeled in the PSCAD/EMTDC simulation platform. According to the simulation analysis, the DC grid can adopt the converter with fault clearing ability or an AC circuit breaker to cooperate with the fast disconnector (FD) to complete fault clearing in the DC fault area under the proposed zonal protection coordination strategy.