Oleksii Babenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleksii Babenko has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Mykhailo Burbelo
Вінницький національний технічний університет
3 shared publications - Denys Lebed
Vinnytsia National Technical University
2 shared publications - Dmytro Stepanov
Вінницький національний технічний університет
2 shared publications - Natalia Stepanova
Vinnytsia National Technical University
2 shared publications Khmelnytskyi National University
1 shared publicationLyudmila Protsenko
1 shared publication
Latest Publications
- 1 July 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (4) , 67-74
DIRECT CONTROL METHOD FOR STATCOM TO MITIGATE VOLTAGE FLUCTUATIONS AT A DISTRIBUTION NETWORK LOAD BUS
The article proposes a method of direct control of the static synchronous compensator (STATCOM) to reduce voltage fluctuations due to load and supply voltage instability in distribution electric networks. The operation of the STATCOM operating in the voltage stabilization mode of the 10 kV distribution electric network node is analyzed. The value of the compensator EMF is obtained, which provides a stable value of the load node voltage when the consumer load conduc-tivity changes. The specified EMF is determined by the values of the increments of the active and reactive components of the load current, the voltage of the compensator connection node at a zero value of the STATCOM reactive current and the parameters of the electric network. The process of voltage stabilization in the load connection node under the condition of changes in the power source voltage and the corresponding compensator control law are analyzed, which involves the use of such informative parameters as the current and base values of the power source voltage, network parameters, and the voltage of the STATCOM connection node. Expressions for determining the EMF of the STAT-COM, which provides a stable voltage at the compensator connection point and the load, as well as a zero value of the active power in the compensator circuit under unstable load conditions, as well as changes in the power supply voltage, are obtained. It is shown that for the efficient operation of the compensator, it is necessary to perform measurements of the load currents and the load bus voltage. The STATCOM operation is simulated under the condition of changing the active and reactive load of the consumer in the range of ±25% and fluctuations in the power supply voltage within 2%, which is most often observed in electrical networks. It is shown that for an average load power of 4+j2 MVA and a stabilized voltage of 10.25 kV, the compensator power ranges from −0.57 MVAr to 2.4 MVAr. If the voltage stabiliza-tion level needs to be increased to 10.3 kV, the compensator power rises to 2.8 MVAr. References 16, Fig. 7, Table 1.
- 1 July 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (4) , 67-74
DIRECT CONTROL METHOD FOR STATCOM TO MITIGATE VOLTAGE FLUCTUATIONS AT A DISTRIBUTION NETWORK LOAD BUS
The article proposes a method of direct control of the static synchronous compensator (STATCOM) to reduce voltage fluctuations due to load and supply voltage instability in distribution electric networks. The operation of the STATCOM operating in the voltage stabilization mode of the 10 kV distribution electric network node is analyzed. The value of the compensator EMF is obtained, which provides a stable value of the load node voltage when the consumer load conduc-tivity changes. The specified EMF is determined by the values of the increments of the active and reactive components of the load current, the voltage of the compensator connection node at a zero value of the STATCOM reactive current and the parameters of the electric network. The process of voltage stabilization in the load connection node under the condition of changes in the power source voltage and the corresponding compensator control law are analyzed, which involves the use of such informative parameters as the current and base values of the power source voltage, network parameters, and the voltage of the STATCOM connection node. Expressions for determining the EMF of the STAT-COM, which provides a stable voltage at the compensator connection point and the load, as well as a zero value of the active power in the compensator circuit under unstable load conditions, as well as changes in the power supply voltage, are obtained. It is shown that for the efficient operation of the compensator, it is necessary to perform measurements of the load currents and the load bus voltage. The STATCOM operation is simulated under the condition of changing the active and reactive load of the consumer in the range of ±25% and fluctuations in the power supply voltage within 2%, which is most often observed in electrical networks. It is shown that for an average load power of 4+j2 MVA and a stabilized voltage of 10.25 kV, the compensator power ranges from −0.57 MVAr to 2.4 MVAr. If the voltage stabiliza-tion level needs to be increased to 10.3 kV, the compensator power rises to 2.8 MVAr. References 16, Fig. 7, Table 1.
- Open Access
- 28 May 2026
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 365 (3) , 118-123
ПОРІВНЯННЯ СТРАТЕГІЙ КЕРУВАННЯ УНІФІКОВАНИМИ РЕГУЛЯТОРАМИ ЯКОСТІ ЕЛЕКТРОЕНЕРГІЇ ДЛЯ СТАБІЛІЗАЦІЇ НАПРУГИ У ВУЗЛІ НАВАНТАЖЕННЯ РОЗПОДІЛЬНОЇ МЕРЕЖІ
The paper presents a comparison of three control strategies for a Unified Power Quality Conditioner (UPQC) with a left-shunt configuration (parallel compensator connected on the source side) aimed at mitigating voltage fluctuations caused by supply voltage instability. The first strategy (Q-type UPQC) ensures that the regulator injects a voltage in quadrature with the load current. The second strategy (P-type UPQC) involves generating a voltage that is in phase with the load current. The third control strategy is employed in S-type conditioners, which generate a voltage with a phase angle relative to the load current ranging between 0 and π/2. Control laws were derived as dependencies of the series and shunt compensator EMFs on the supply voltage for Q-, P-, and S-type UPQCs to maintain a stable voltage at the load node. The voltage stabilization process at the load connection point was analyzed under supply voltage variations within the range of 10.5–10.0 kV, utilizing a corresponding UPQC control law based on informative parameters such as the current and base source EMF values and network parameters. Simulations were conducted for Q-, P-, and S-type UPQCs under two conditions: maximum reactive power compensation by the shunt compensator, and minimum reactive power compensation by both the shunt and series compensators. It is shown that the advantage of the Q-type UPQC compared to the S-type and P-type is the capability for a significant load voltage boost. In P-type and S-type UPQCs, such an increase is difficult to implement due to the non-identity of the active power consumption and generation dependencies of the shunt and series compensators. It is demonstrated that for voltage variations within 10.5–10.0 kV, the S-type UPQC exhibits lower active power, whereas for variations within 10.5–10.3 kV, the P-type UPQC has lower active power.
- 28 May 2026
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 365 (3) , 118-123
Open AccessПОРІВНЯННЯ СТРАТЕГІЙ КЕРУВАННЯ УНІФІКОВАНИМИ РЕГУЛЯТОРАМИ ЯКОСТІ ЕЛЕКТРОЕНЕРГІЇ ДЛЯ СТАБІЛІЗАЦІЇ НАПРУГИ У ВУЗЛІ НАВАНТАЖЕННЯ РОЗПОДІЛЬНОЇ МЕРЕЖІ
The paper presents a comparison of three control strategies for a Unified Power Quality Conditioner (UPQC) with a left-shunt configuration (parallel compensator connected on the source side) aimed at mitigating voltage fluctuations caused by supply voltage instability. The first strategy (Q-type UPQC) ensures that the regulator injects a voltage in quadrature with the load current. The second strategy (P-type UPQC) involves generating a voltage that is in phase with the load current. The third control strategy is employed in S-type conditioners, which generate a voltage with a phase angle relative to the load current ranging between 0 and π/2. Control laws were derived as dependencies of the series and shunt compensator EMFs on the supply voltage for Q-, P-, and S-type UPQCs to maintain a stable voltage at the load node. The voltage stabilization process at the load connection point was analyzed under supply voltage variations within the range of 10.5–10.0 kV, utilizing a corresponding UPQC control law based on informative parameters such as the current and base source EMF values and network parameters. Simulations were conducted for Q-, P-, and S-type UPQCs under two conditions: maximum reactive power compensation by the shunt compensator, and minimum reactive power compensation by both the shunt and series compensators. It is shown that the advantage of the Q-type UPQC compared to the S-type and P-type is the capability for a significant load voltage boost. In P-type and S-type UPQCs, such an increase is difficult to implement due to the non-identity of the active power consumption and generation dependencies of the shunt and series compensators. It is demonstrated that for voltage variations within 10.5–10.0 kV, the S-type UPQC exhibits lower active power, whereas for variations within 10.5–10.3 kV, the P-type UPQC has lower active power.
- 1 January 2025
- Published by Publishing House Helvetica (Publications) in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
- No. 1,p. 284-291
ANALYSIS OF STATCOM CONTROL PROCESS UNDER RAPID VOLTAGE CHANGES
- 1 January 2025
- Published by Publishing House Helvetica (Publications) in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
- No. 1,p. 284-291
ANALYSIS OF STATCOM CONTROL PROCESS UNDER RAPID VOLTAGE CHANGES
- Open Access
- 21 November 2024
- Published by Vinnytsia National Technical University
INCREASING THE EFFICIENCY OF THE USE OF MEASURING TRANSFORMERS DURING ELECTRICITY METERING
Error limits of current and voltage measuring transformers are given and analyzed. The influence of factors on the accuracy of current and voltage measurement, as well as accounting of active and reactive electricity using current and voltage measuring transformers, was analyzed. In particular, for a measuring current transformer, such factors are the load schedule of the consumer, individual metrological characteristics of the transformer itself, as well as the load of its secondary winding (load). As for measuring voltage transformers, the accuracy of their operation is affected by the value of the load and individual metrological characteristics. It is emphasized that for the effective use of current and voltage measuring transformers at specific objects, it is necessary to conduct research in order to obtain initial information that will help to substantiate the specified efficiency: graphs of consumer loads, loads of secondary circuits, metrological characteristics. The analysis of the received information makes it possible to outline the most appropriate measures to increase the specified efficiency: optimization of the loading of the secondary circuits of the measuring transformers by, for example, choosing the optimal switching scheme, applying additional loads, as well as using measuring transformers of a higher accuracy class. An analysis of the results of the verification of voltage measuring transformers is given, which showed that the accuracy class of the indicated transformers corresponds to the values standardized by the state standard for loads from 25 to 100%, and in the case of a smaller or larger load, their error increases. In particular, with a smaller load, the error increases in the positive direction and reaches up to +0.5% per phase. The latter, in turn, leads to an increase in the measurement error of active or reactive energy in a threephase network of consumers up to +1.5%.
- 21 November 2024
- Published by Vinnytsia National Technical University
Open AccessINCREASING THE EFFICIENCY OF THE USE OF MEASURING TRANSFORMERS DURING ELECTRICITY METERING
Error limits of current and voltage measuring transformers are given and analyzed. The influence of factors on the accuracy of current and voltage measurement, as well as accounting of active and reactive electricity using current and voltage measuring transformers, was analyzed. In particular, for a measuring current transformer, such factors are the load schedule of the consumer, individual metrological characteristics of the transformer itself, as well as the load of its secondary winding (load). As for measuring voltage transformers, the accuracy of their operation is affected by the value of the load and individual metrological characteristics. It is emphasized that for the effective use of current and voltage measuring transformers at specific objects, it is necessary to conduct research in order to obtain initial information that will help to substantiate the specified efficiency: graphs of consumer loads, loads of secondary circuits, metrological characteristics. The analysis of the received information makes it possible to outline the most appropriate measures to increase the specified efficiency: optimization of the loading of the secondary circuits of the measuring transformers by, for example, choosing the optimal switching scheme, applying additional loads, as well as using measuring transformers of a higher accuracy class. An analysis of the results of the verification of voltage measuring transformers is given, which showed that the accuracy class of the indicated transformers corresponds to the values standardized by the state standard for loads from 25 to 100%, and in the case of a smaller or larger load, their error increases. In particular, with a smaller load, the error increases in the positive direction and reaches up to +0.5% per phase. The latter, in turn, leads to an increase in the measurement error of active or reactive energy in a threephase network of consumers up to +1.5%.
- Open Access
- 29 July 2024
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 337 (3(2)) , 27-32
МОДЕЛЮВАННЯ ЕНЕРГОЕФЕКТИВНОСТІ ЖИТЛОВОЇ БУДІВЛІ ЗА УМОВ РІЗНИХ ДЖЕРЕЛ ТЕПЛОВОЇ ЕНЕРГІЇ
The paper presents the results of modeling the process of energy consumption in public, residential, and commercial buildings as a result of the use of various sources of thermal energy. Buildings with such energy sources as: a) a low-temperature gas boiler with a capacity of up to 120 kW for the needs of heat supply of a residential building and freon air conditioning systems for the needs of cooling the building; b) a gas condensing boiler with a thermal capacity of up to 120 kW with a temperature regime of 55/45°C for heat supply and freon air conditioning systems for cooling; c) reversible heat pumping unit of the “ground-water” type with a temperature regime of 35/28°C for the needs of the heating and cooling system and a reversible heat pumping machine with a regime of 55/45°C for the needs of hot water supply; d) a reversible air-to-air heat pump for heating and cooling systems and electric boilers for hot water supply; e) a biomass solid fuel boiler with manual fuel loading with a heat output of more than 100 kW for heat supply and freon systems for cooling; f) a fuel pellet boiler with automatic mechanized fuel loading with a heat output of more than 100 kW for building heating and cooling and freon systems for cooling; g) centralized heating system of the building. The results of calculations of the specific primary energy consumption and specific greenhouse gas emissions for each of the above heat sources are presented. It is established that biomass boilers have the lowest values of primary energy consumption and specific greenhouse gas emissions. The lowest efficiency is achieved by a district heating system with a centralized energy source. The modeling was conducted for the climatic conditions of Vinnytsia. At the same time, the disadvantage of using solid fuel boilers is the limitation of their use in densely populated areas, which is explained by the complexity of flue gas cleaning and regular biomass supply. Therefore, it has been determined that the most efficient source of thermal energy for buildings of various types to achieve the standardized energy efficiency indicators is a ground-to-water heat pump system. This installation, along with providing buildings with thermal energy, allows for cooling in the warm season, operating in reverse mode.
- 29 July 2024
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 337 (3(2)) , 27-32
Open AccessМОДЕЛЮВАННЯ ЕНЕРГОЕФЕКТИВНОСТІ ЖИТЛОВОЇ БУДІВЛІ ЗА УМОВ РІЗНИХ ДЖЕРЕЛ ТЕПЛОВОЇ ЕНЕРГІЇ
The paper presents the results of modeling the process of energy consumption in public, residential, and commercial buildings as a result of the use of various sources of thermal energy. Buildings with such energy sources as: a) a low-temperature gas boiler with a capacity of up to 120 kW for the needs of heat supply of a residential building and freon air conditioning systems for the needs of cooling the building; b) a gas condensing boiler with a thermal capacity of up to 120 kW with a temperature regime of 55/45°C for heat supply and freon air conditioning systems for cooling; c) reversible heat pumping unit of the “ground-water” type with a temperature regime of 35/28°C for the needs of the heating and cooling system and a reversible heat pumping machine with a regime of 55/45°C for the needs of hot water supply; d) a reversible air-to-air heat pump for heating and cooling systems and electric boilers for hot water supply; e) a biomass solid fuel boiler with manual fuel loading with a heat output of more than 100 kW for heat supply and freon systems for cooling; f) a fuel pellet boiler with automatic mechanized fuel loading with a heat output of more than 100 kW for building heating and cooling and freon systems for cooling; g) centralized heating system of the building. The results of calculations of the specific primary energy consumption and specific greenhouse gas emissions for each of the above heat sources are presented. It is established that biomass boilers have the lowest values of primary energy consumption and specific greenhouse gas emissions. The lowest efficiency is achieved by a district heating system with a centralized energy source. The modeling was conducted for the climatic conditions of Vinnytsia. At the same time, the disadvantage of using solid fuel boilers is the limitation of their use in densely populated areas, which is explained by the complexity of flue gas cleaning and regular biomass supply. Therefore, it has been determined that the most efficient source of thermal energy for buildings of various types to achieve the standardized energy efficiency indicators is a ground-to-water heat pump system. This installation, along with providing buildings with thermal energy, allows for cooling in the warm season, operating in reverse mode.
- Open Access
- 20 December 2023
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 13 (4) , 109-113
AUTOMATIC ADJUSTMENT OF REACTIVE POWER BY FACTS DEVICES UNDER CONDITIONS OF VOLTAGE INSTABILITY IN THE ELECTRIC NETWORK
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in case of voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The task of STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generated by the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However, at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solve this problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation. In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle of the voltage vector changes, which causes a failure in the operation of the regulator of the parallel compensator UPFC. W artykule opisano problematykę automatycznej regulacji mocy biernej za pomocą urządzeń elektronicznych FACTS (Flexible AC Transmission Systems): statycznego kompensatora synchronicznego (STATCOM) oraz regulatora przepływu mocy (UPFC). Za pomocą złożonego formularza rejestracyjnego określane są: napięcia w węzłach instalacji urządzenia FACTS i obciążenia, prądy obciążenia, źródeł zasilania i kompensatorów elektronicznych w przypadku niestabilności napięcia w węźle obciążenia sieci elektrycznej. Napięcia i prądy są wyznaczane metodą napięć węzłowych. Zadaniem STATCOM jest częściowa lub pełna kompensacja mocy biernej. Podczas spadku napięcia w węźle obciążenia, moc bierna generowana przez źródło zasilania maleje. STATCOM powinien częściowo lub w pełni skompensować nierównowagę mocy biernej tak szybko, jak to możliwe. Jednocześnie jednak nie jest możliwe pełne skompensowanie spadku napięcia. W celu rozwiązania tego problemu można zastosować szeregowo-równoległy lub równoległo-szeregowy układ UPFC. W wyniku zastosowania UPFC możliwe jest automatyczne podniesienie poziomu napięcia do akceptowalnych wartości za pomocą kompensatora szeregowego UPFC. Analiza pokazuje, że równoległo-szeregowy UPFC charakteryzuje się stabilnością działania. W przypadku zastosowania szeregowo-równoległego UPFC istnieją ograniczenia w zakresie możliwości regulacji składowej urojonej napięcia kompensatora szeregowego, ponieważ zmienia się kąt wektora napięcia, co powoduje awarię działania regulatora kompensatora równoległego UPFC.
- 20 December 2023
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 13 (4) , 109-113
Open AccessAUTOMATIC ADJUSTMENT OF REACTIVE POWER BY FACTS DEVICES UNDER CONDITIONS OF VOLTAGE INSTABILITY IN THE ELECTRIC NETWORK
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in case of voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The task of STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generated by the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However, at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solve this problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation. In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle of the voltage vector changes, which causes a failure in the operation of the regulator of the parallel compensator UPFC. W artykule opisano problematykę automatycznej regulacji mocy biernej za pomocą urządzeń elektronicznych FACTS (Flexible AC Transmission Systems): statycznego kompensatora synchronicznego (STATCOM) oraz regulatora przepływu mocy (UPFC). Za pomocą złożonego formularza rejestracyjnego określane są: napięcia w węzłach instalacji urządzenia FACTS i obciążenia, prądy obciążenia, źródeł zasilania i kompensatorów elektronicznych w przypadku niestabilności napięcia w węźle obciążenia sieci elektrycznej. Napięcia i prądy są wyznaczane metodą napięć węzłowych. Zadaniem STATCOM jest częściowa lub pełna kompensacja mocy biernej. Podczas spadku napięcia w węźle obciążenia, moc bierna generowana przez źródło zasilania maleje. STATCOM powinien częściowo lub w pełni skompensować nierównowagę mocy biernej tak szybko, jak to możliwe. Jednocześnie jednak nie jest możliwe pełne skompensowanie spadku napięcia. W celu rozwiązania tego problemu można zastosować szeregowo-równoległy lub równoległo-szeregowy układ UPFC. W wyniku zastosowania UPFC możliwe jest automatyczne podniesienie poziomu napięcia do akceptowalnych wartości za pomocą kompensatora szeregowego UPFC. Analiza pokazuje, że równoległo-szeregowy UPFC charakteryzuje się stabilnością działania. W przypadku zastosowania szeregowo-równoległego UPFC istnieją ograniczenia w zakresie możliwości regulacji składowej urojonej napięcia kompensatora szeregowego, ponieważ zmienia się kąt wektora napięcia, co powoduje awarię działania regulatora kompensatora równoległego UPFC.
- 30 March 2023
- Published by Khmelnytskyi National University in Вісник Хмельницького національного університету. Економічні науки
- Vol. 314 (1) , 85-88
SIMULATION OF COMPLEX EFFECTS OF THERMAL MODERNIZATION MEASURES OF THE BUILDING TAKING INTO ACCOUNT INVESTMENT LIMITATIONS
The article simulates the impact of the complex application of energy-saving measures on the energy efficiency indicators of a public brick building. During modeling, the economic factor – capital investment in energy saving measures – was taken into account. Similar simulations are carried out during energy audits of various types of buildings. Performing energy audits of residential and public buildings in the city is, in accordance with the Law of Ukraine “On Energy Efficiency”, an important part of Ukraine’s energy conservation policy. Energy audits are required for: a) development of an energy certificate, which is required for many new and existing buildings in accordance with current legislation; b) attraction of funds from the energy efficiency fund and other funds for the needs of thermal modernization; c) obtaining reasonable indicators that will allow building owners to make energy-efficient decisions. The energy audit report contains three stages: the stage of obtaining information, the stage of analyzing information and developing energy-saving recommendations, and the stage of technical and economic substantiation of the proposed energy-saving recommendations. At the first stage, energy auditors collect raw data about buildings. Existing buildings are often characterized by the lack of insulation of opaque enclosing structures, the presence of translucent enclosing structures, the reduced heat transfer supports of which are significantly lower than the minimum permissible values, and outdated sources of heat supply. During the second stage, mathematical models are developed that allow obtaining technical and economic indicators of energy saving measures. The third stage is the substantiation of optimal measures that must satisfy technical and economic constraints. The work analyzed the dependence of the general indicator of specific energy consumption during heating and cooling of a two-story brick public building under the condition of modernization of the gas boiler, as well as insulation of the brick facades of the building with polystyrene foam plates of different thicknesses. At the same time, an analysis of both individual and complex application of the specified measures was carried out. General capital investment in thermal modernization was adopted as an economic indicator that sets limits on energy saving measures. As a result of the modeling, it was established that in order to determine the optimal measures to increase the energy efficiency of the building, it is necessary to use optimization mathematical devices that take into account the existing restrictions and can be integrated into mathematical models that calculate the basic level of energy consumption in compliance with the normative parameters of the building’s operation.
- 30 March 2023
- Published by Khmelnytskyi National University in Вісник Хмельницького національного університету. Економічні науки
- Vol. 314 (1) , 85-88
SIMULATION OF COMPLEX EFFECTS OF THERMAL MODERNIZATION MEASURES OF THE BUILDING TAKING INTO ACCOUNT INVESTMENT LIMITATIONS
The article simulates the impact of the complex application of energy-saving measures on the energy efficiency indicators of a public brick building. During modeling, the economic factor – capital investment in energy saving measures – was taken into account. Similar simulations are carried out during energy audits of various types of buildings. Performing energy audits of residential and public buildings in the city is, in accordance with the Law of Ukraine “On Energy Efficiency”, an important part of Ukraine’s energy conservation policy. Energy audits are required for: a) development of an energy certificate, which is required for many new and existing buildings in accordance with current legislation; b) attraction of funds from the energy efficiency fund and other funds for the needs of thermal modernization; c) obtaining reasonable indicators that will allow building owners to make energy-efficient decisions. The energy audit report contains three stages: the stage of obtaining information, the stage of analyzing information and developing energy-saving recommendations, and the stage of technical and economic substantiation of the proposed energy-saving recommendations. At the first stage, energy auditors collect raw data about buildings. Existing buildings are often characterized by the lack of insulation of opaque enclosing structures, the presence of translucent enclosing structures, the reduced heat transfer supports of which are significantly lower than the minimum permissible values, and outdated sources of heat supply. During the second stage, mathematical models are developed that allow obtaining technical and economic indicators of energy saving measures. The third stage is the substantiation of optimal measures that must satisfy technical and economic constraints. The work analyzed the dependence of the general indicator of specific energy consumption during heating and cooling of a two-story brick public building under the condition of modernization of the gas boiler, as well as insulation of the brick facades of the building with polystyrene foam plates of different thicknesses. At the same time, an analysis of both individual and complex application of the specified measures was carried out. General capital investment in thermal modernization was adopted as an economic indicator that sets limits on energy saving measures. As a result of the modeling, it was established that in order to determine the optimal measures to increase the energy efficiency of the building, it is necessary to use optimization mathematical devices that take into account the existing restrictions and can be integrated into mathematical models that calculate the basic level of energy consumption in compliance with the normative parameters of the building’s operation.
- 23 February 2023
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 217 (1)
STUDY OF THE EFFICIENCY OF THE APPLICATION OF BIOGAS INSTALLATIONS AT ENTERPRISES OF THE AGRICULTURAL COMPLEX
The issue of energy saving is becoming more and more urgent, taking into account the destruction of power generating facilities. One of the energy saving options is the use of alternative energy sources. This is not only an economic benefit for consumers, but also a reduction in the load on electrical networks and maintenance of the reliability of the power system due to the decentralization of electricity generation in wartime conditions. Alternative sources of electricity include energy from the sun, wind, seas, rivers, biomass, and Earth’s heat. At the same time, their effectiveness depends on many factors. Since Ukraine has a powerful industrial agricultural complex, its share in GDP is about 10% and its share is growing annually, therefore, an urgent task is to analyze the feasibility of using biogas plants at livestock, agro-processing and municipal waste enterprises. We should not forget about the environmental friendliness of electricity production using biogas plants, which will ensure the preservation of the environment, and therefore the health of descendants. Enterprises of the agro-industrial complex for the production of products require significant amounts of electrical energy, along with this, the waste of the activities of such enterprises is sewage and organic waste in landfills, from which biomass can be obtained. Biomass, in turn, is the raw material for the production of biogas, which is needed by biogas plants to generate electrical energy. Analysis of the amount of waste from agro-industrial complex enterprises, which can be used as raw materials for the production of biogas, showed that Ukraine has prospects for the development of biogas energy, based on a powerful agricultural sector. The use of biogas plants will provide electricity, heat and hot water to enterprises of the agrarian complex, and will reduce the load on traditional energy sources.
- 23 February 2023
- Published by Khmelnytskyi National University in Herald of Khmelnytskyi National University. Technical sciences
- Vol. 217 (1)
STUDY OF THE EFFICIENCY OF THE APPLICATION OF BIOGAS INSTALLATIONS AT ENTERPRISES OF THE AGRICULTURAL COMPLEX
The issue of energy saving is becoming more and more urgent, taking into account the destruction of power generating facilities. One of the energy saving options is the use of alternative energy sources. This is not only an economic benefit for consumers, but also a reduction in the load on electrical networks and maintenance of the reliability of the power system due to the decentralization of electricity generation in wartime conditions. Alternative sources of electricity include energy from the sun, wind, seas, rivers, biomass, and Earth’s heat. At the same time, their effectiveness depends on many factors. Since Ukraine has a powerful industrial agricultural complex, its share in GDP is about 10% and its share is growing annually, therefore, an urgent task is to analyze the feasibility of using biogas plants at livestock, agro-processing and municipal waste enterprises. We should not forget about the environmental friendliness of electricity production using biogas plants, which will ensure the preservation of the environment, and therefore the health of descendants. Enterprises of the agro-industrial complex for the production of products require significant amounts of electrical energy, along with this, the waste of the activities of such enterprises is sewage and organic waste in landfills, from which biomass can be obtained. Biomass, in turn, is the raw material for the production of biogas, which is needed by biogas plants to generate electrical energy. Analysis of the amount of waste from agro-industrial complex enterprises, which can be used as raw materials for the production of biogas, showed that Ukraine has prospects for the development of biogas energy, based on a powerful agricultural sector. The use of biogas plants will provide electricity, heat and hot water to enterprises of the agrarian complex, and will reduce the load on traditional energy sources.