Yu-Min Hsin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu-Min Hsin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Chien Kuo
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
3 shared publications - Bo-Hao Zhou
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
1 shared publication - Chen-Cheng Lee
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
1 shared publication - Chia-Ming Chang
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
1 shared publication - Chun-Yu Lin
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
1 shared publication - Shang-Chun Dai
Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6323
Performance Analysis and Control Design Methods for Grid-Forming Photovoltaic Converters in Black-Start Scenarios
With global demand for renewable energy increasing, the penetration of photovoltaic (PV) systems in power networks has risen significantly, introducing new challenges to microgrid stability. This study focuses on solar inverters using grid-forming (GFM) control, investigating their performance in black-start scenarios and in stabilizing microgrids with battery energy storage systems (BESSs). A MATLAB Simulink microgrid model integrating PV, BESS, and GFM inverters was developed to simulate scenarios including black start, load variation, grid synchronization, and power adjustment. Control techniques such as droop control, proportional–integral (PI) control, Clarke and Park transformations, and phase-locked loops (PLLs) were applied for precise regulation of voltage, frequency, and power. Results show that GFM inverters effectively stabilize voltage and frequency during load changes and PV grid connection, maintaining voltage between 0.96–1.003 p.u. and frequency within 59.87–60.07 Hz. The findings confirm the feasibility of GFM control for coordinated PV–BESS operation and support stable microgrid operation under high renewable penetration.
- 24 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6323
Open AccessPerformance Analysis and Control Design Methods for Grid-Forming Photovoltaic Converters in Black-Start Scenarios
With global demand for renewable energy increasing, the penetration of photovoltaic (PV) systems in power networks has risen significantly, introducing new challenges to microgrid stability. This study focuses on solar inverters using grid-forming (GFM) control, investigating their performance in black-start scenarios and in stabilizing microgrids with battery energy storage systems (BESSs). A MATLAB Simulink microgrid model integrating PV, BESS, and GFM inverters was developed to simulate scenarios including black start, load variation, grid synchronization, and power adjustment. Control techniques such as droop control, proportional–integral (PI) control, Clarke and Park transformations, and phase-locked loops (PLLs) were applied for precise regulation of voltage, frequency, and power. Results show that GFM inverters effectively stabilize voltage and frequency during load changes and PV grid connection, maintaining voltage between 0.96–1.003 p.u. and frequency within 59.87–60.07 Hz. The findings confirm the feasibility of GFM control for coordinated PV–BESS operation and support stable microgrid operation under high renewable penetration.
- Open Access
- 24 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (9) , 4200
Inertia Estimation in High-RES Power Systems Using Small-Signal Power Injection
This paper proposes a continuous inertia estimation framework for transmission-level power systems with high renewable energy penetration, using a battery energy storage system (BESS) as a controllable small-signal power injection source. The proposed framework integrates BESS-based active power injection, a two-stage signal-smoothing scheme, and a rate-of-change-of-frequency (RoCoF)-based estimation mechanism to enable continuous inertia estimation without relying on major disturbance events. With noise-robust processing and moving-window analysis, the framework can reliably track inertia variations under noisy measurement conditions and diverse operating scenarios. The framework is validated on the IEEE 39-bus system under renewable energy source (RES) penetration levels of 0%, 10%, 20%, and 30%. The estimation error remains within ±3.5% across all scenarios, ranging from 1.26% at 0% RES penetration to 3.43% at 30% penetration. In addition, the estimated inertia closely follows the theoretical decrease from 3.20 s to 2.22 s as RES penetration increases. These results demonstrate the accuracy and robustness of the proposed framework for continuous inertia monitoring in low-inertia power systems with high-RES penetration.
- 24 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (9) , 4200
Open AccessInertia Estimation in High-RES Power Systems Using Small-Signal Power Injection
This paper proposes a continuous inertia estimation framework for transmission-level power systems with high renewable energy penetration, using a battery energy storage system (BESS) as a controllable small-signal power injection source. The proposed framework integrates BESS-based active power injection, a two-stage signal-smoothing scheme, and a rate-of-change-of-frequency (RoCoF)-based estimation mechanism to enable continuous inertia estimation without relying on major disturbance events. With noise-robust processing and moving-window analysis, the framework can reliably track inertia variations under noisy measurement conditions and diverse operating scenarios. The framework is validated on the IEEE 39-bus system under renewable energy source (RES) penetration levels of 0%, 10%, 20%, and 30%. The estimation error remains within ±3.5% across all scenarios, ranging from 1.26% at 0% RES penetration to 3.43% at 30% penetration. In addition, the estimated inertia closely follows the theoretical decrease from 3.20 s to 2.22 s as RES penetration increases. These results demonstrate the accuracy and robustness of the proposed framework for continuous inertia monitoring in low-inertia power systems with high-RES penetration.
- Open Access
- 14 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4943
Optimal Modeling for Dynamic Response of Energy Storage Systems
Using energy storage systems with solar and wind energy can overcome the intermittence of these types of renewable energy. According to the regulations made by the utilities in each country, facilities that are connected to the power grid should be assessed on how they influence the power grid. Power system simulation software such as PSS/E, DIgSILENT, and DSATools are widely used by utilities. The default models in these kinds of software are defined by the Western Electricity Coordinating Council (WECC). Improper parameters will produce estimation results that are not informative, and the utilities may make wrong decisions. To avoid this problem, this study designed the process to find suitable parameters for real energy storage systems. Using models created by the WECC and reducing it according to the application condition decreased the burden of the optimization process. We used two algorithms and their improved versions to search for an appropriate value of variables that can represent a real energy storage system. We also compared the results between the BESS simplified model that we built and the original model from PSS/E.
- 14 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4943
Open AccessOptimal Modeling for Dynamic Response of Energy Storage Systems
Using energy storage systems with solar and wind energy can overcome the intermittence of these types of renewable energy. According to the regulations made by the utilities in each country, facilities that are connected to the power grid should be assessed on how they influence the power grid. Power system simulation software such as PSS/E, DIgSILENT, and DSATools are widely used by utilities. The default models in these kinds of software are defined by the Western Electricity Coordinating Council (WECC). Improper parameters will produce estimation results that are not informative, and the utilities may make wrong decisions. To avoid this problem, this study designed the process to find suitable parameters for real energy storage systems. Using models created by the WECC and reducing it according to the application condition decreased the burden of the optimization process. We used two algorithms and their improved versions to search for an appropriate value of variables that can represent a real energy storage system. We also compared the results between the BESS simplified model that we built and the original model from PSS/E.