Liem H. T. Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liem H. T. Nguyen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hyusim Park
Department of Electrical Engineering, University of North Texas, Dallas, TX, USA
3 shared publications - Sungyong Jung
Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD, USA
3 shared publications Chenyun Pan
University Of Texas at Arlington,Department of Electrical Engineering,Arlington,United States
1 shared publication- Christopher D. Delhom
USDA-ARS, New Orleans, USA
1 shared publication - Chulwoo Pack
Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD, USA
1 shared publication Hyusim Park
University Of Texas at Arlington,Department of Electrical Engineering,Arlington,United States
1 shared publication
Latest Publications
- Open Access
Design of a Distance-Compensated Infrared Thermometer for Canopy Temperature Monitoring
Infrared (IR) thermometry is essential for non-contact surface temperature monitoring in precision agriculture, but conventional single-pixel devices exhibit distance-dependent measurement errors that hinder field deployment. Most existing solutions require either fixed-geometry installations, post-processing corrections, or expensive thermal imaging systems with computational overhead. This paper presents the design, development, and evaluation of an IR thermometer measurement system that implements a lightweight signal processing algorithm for distance compensation. The instrumentation module integrates the thermometer’s temperature signal with ultrasonic distance measurements and employs a distance-bias lookup table (LUT) calibrated at regulated setpoints. Real-time signal conditioning through bilinear interpolation generates corrected temperature outputs. Under controlled reference-target conditions, system evaluation across 5–200 cm shows that uncompensated errors reach approximately −5 °C at 200 cm, whereas the proposed signal processing reduces the distance-dependent residual RMSE to below 0.20 °C over the tested range. The instrument also preserves short-term repeatability, with standard deviations between 0.08 °C and 0.12 °C across stand-off distances from 20 to 200 cm. By delivering distance-invariant measurements through external signal processing, the system is designed to support flexible, height-independent deployment of single-pixel IR thermometry for precision agriculture applications such as canopy temperature monitoring. A preliminary field measurement on a live tree canopy under one overcast condition provides initial evidence that the distance-dependent drift can be reduced outdoors, with the compensated output remaining within 0.7 °C of an external handheld reference across the 5–200 cm range; comprehensive multi-condition field validation remains necessary in future work.
Open AccessDesign of a Distance-Compensated Infrared Thermometer for Canopy Temperature Monitoring
Infrared (IR) thermometry is essential for non-contact surface temperature monitoring in precision agriculture, but conventional single-pixel devices exhibit distance-dependent measurement errors that hinder field deployment. Most existing solutions require either fixed-geometry installations, post-processing corrections, or expensive thermal imaging systems with computational overhead. This paper presents the design, development, and evaluation of an IR thermometer measurement system that implements a lightweight signal processing algorithm for distance compensation. The instrumentation module integrates the thermometer’s temperature signal with ultrasonic distance measurements and employs a distance-bias lookup table (LUT) calibrated at regulated setpoints. Real-time signal conditioning through bilinear interpolation generates corrected temperature outputs. Under controlled reference-target conditions, system evaluation across 5–200 cm shows that uncompensated errors reach approximately −5 °C at 200 cm, whereas the proposed signal processing reduces the distance-dependent residual RMSE to below 0.20 °C over the tested range. The instrument also preserves short-term repeatability, with standard deviations between 0.08 °C and 0.12 °C across stand-off distances from 20 to 200 cm. By delivering distance-invariant measurements through external signal processing, the system is designed to support flexible, height-independent deployment of single-pixel IR thermometry for precision agriculture applications such as canopy temperature monitoring. A preliminary field measurement on a live tree canopy under one overcast condition provides initial evidence that the distance-dependent drift can be reduced outdoors, with the compensated output remaining within 0.7 °C of an external handheld reference across the 5–200 cm range; comprehensive multi-condition field validation remains necessary in future work.
- Open Access
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 67435-67446
Real-Time Vehicle Speed Gun With LiDAR–Camera Fusion
This paper presents a dual-sensor speed measurement system that fuses LiDAR-based distance ranging with depth-camera tracking through a Kalman filter. We quantitatively evaluate the separate contributions of per-modality filtering and dual-modal fusion via outdoor vehicle experiments encompassing acceleration, deceleration, and steady-state driving conditions. Per-sensor filtering reduces distance error and suppresses high-frequency measurement jitter, while sensor fusion further lowers the root-mean-square error (RMSE) and produces speed profiles that closely match ground-truth measurements. The proposed system operates in real time on a Raspberry Pi platform. Time-stamped CSV speed logs and synchronized, annotated video from real vehicle trials are provided to enable independent validation. The results demonstrate that complementary sensing combined with probabilistic sensor fusion offers a practical and deployable solution for accurate speed measurement under real-world conditions. The fused system achieves a speed root-mean-square error (RMSE) of 0.4993 mph and a distance RMSE of 0.4339 m, representing improvements of 55% and 56%, respectively, over the raw single-sensor baselines. The primary novelty of this research is the development of a three-stage processing architecture that systematically isolates and quantifies these performance gains achieved by per-modality Kalman filtering and subsequent probabilistic sensor fusion. Furthermore, this architecture is implemented and empirically validated on a resource-constrained Raspberry Pi platform under dynamic, real-world driving conditions.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 67435-67446
Open AccessReal-Time Vehicle Speed Gun With LiDAR–Camera Fusion
This paper presents a dual-sensor speed measurement system that fuses LiDAR-based distance ranging with depth-camera tracking through a Kalman filter. We quantitatively evaluate the separate contributions of per-modality filtering and dual-modal fusion via outdoor vehicle experiments encompassing acceleration, deceleration, and steady-state driving conditions. Per-sensor filtering reduces distance error and suppresses high-frequency measurement jitter, while sensor fusion further lowers the root-mean-square error (RMSE) and produces speed profiles that closely match ground-truth measurements. The proposed system operates in real time on a Raspberry Pi platform. Time-stamped CSV speed logs and synchronized, annotated video from real vehicle trials are provided to enable independent validation. The results demonstrate that complementary sensing combined with probabilistic sensor fusion offers a practical and deployable solution for accurate speed measurement under real-world conditions. The fused system achieves a speed root-mean-square error (RMSE) of 0.4993 mph and a distance RMSE of 0.4339 m, representing improvements of 55% and 56%, respectively, over the raw single-sensor baselines. The primary novelty of this research is the development of a three-stage processing architecture that systematically isolates and quantifies these performance gains achieved by per-modality Kalman filtering and subsequent probabilistic sensor fusion. Furthermore, this architecture is implemented and empirically validated on a resource-constrained Raspberry Pi platform under dynamic, real-world driving conditions.
- Open Access
- 1 March 2023
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 2 (1) , 012801
Watch-Type Dual-Mode Wearable Health Device
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.
- 1 March 2023
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 2 (1) , 012801
Open AccessWatch-Type Dual-Mode Wearable Health Device
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.
- 17 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Portable Indoor Air Quality Measurement System
Poor Indoor Air Quality (IAQ) is one of the sources that is causing health issues which induce multiple irritating or vital symptoms and diseases such as asthma, allergies, and even cancers. Thus, the devices related to personal air quality monitoring is getting more attention in recent era. The existing instruments to measure IAQ are usually expensive and bulky. In this study, a portable and low-cost device to measure IAQ is developed which comprises of two sensors, BME680 and MICS6814. The device is capable of measuring and recording IAQ levels and concentrations of CO, and NH3 continuously, which are considered as hazard gases. The total size of the designed device is 2 cm × 3.2 cm that could be considered as one of the smallest portable air quality measurement devices. Furthermore, it can send the obtained data to user through Bluetooth Low Energy (BLE) with a customized smartphone application.
- 17 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Portable Indoor Air Quality Measurement System
Poor Indoor Air Quality (IAQ) is one of the sources that is causing health issues which induce multiple irritating or vital symptoms and diseases such as asthma, allergies, and even cancers. Thus, the devices related to personal air quality monitoring is getting more attention in recent era. The existing instruments to measure IAQ are usually expensive and bulky. In this study, a portable and low-cost device to measure IAQ is developed which comprises of two sensors, BME680 and MICS6814. The device is capable of measuring and recording IAQ levels and concentrations of CO, and NH3 continuously, which are considered as hazard gases. The total size of the designed device is 2 cm × 3.2 cm that could be considered as one of the smallest portable air quality measurement devices. Furthermore, it can send the obtained data to user through Bluetooth Low Energy (BLE) with a customized smartphone application.