Raoul Di Giovanni
Research Subjects
Raoul Di Giovanni has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Tirabasso
INAIL, DIMEILA, Laboratory Physical Agents, 00078 Monte Porzio Catone, Italy
3 shared publications - Enrico Marchetti
INAIL, Department of Occupational Health, Monte Porzio Catone, 00078 Rome, Italy
3 shared publications - Luigi Fattorini
Department of Physiology and Pharmacology “Vittorio Erspamer”, Sapienza University of Rome, 00185 Rome, Italy
2 shared publications - Massimo Cavacece
University of Rome Tor Vergata
2 shared publications - Marco Tarabini
Department of Mechanical Engineering, Politecnico di Milano, 20133 Milan, Italy
1 shared publication - Pietro Nataletti
National Institute for Insurance against Accidents at Work (INAIL), Monte Porzio Catone, 00078 Rome, Italy
1 shared publication
Latest Publications
- Open Access
- 20 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 36
Interference of Vibration Exposure in the Force Production of the Hand–Arm System
The authors evaluated the short-term neuromuscular effects on the assessment of mechanical hand—arm systems induced by vibrating tools to investigate the relationship between the force exerted and the vibration exposure. The motor task consisted of holding the instrumented handle with the dominant hand at predetermined grip force values. Five subjects took part in the tests. The tests were developed in the absence of vibration and in the presence of vibration at 5 m/s2, 7.5 m/s2 and 10 m/s2. The push and pull force values were calculated in the tests on the five subjects.
- 20 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 36
Open AccessInterference of Vibration Exposure in the Force Production of the Hand–Arm System
The authors evaluated the short-term neuromuscular effects on the assessment of mechanical hand—arm systems induced by vibrating tools to investigate the relationship between the force exerted and the vibration exposure. The motor task consisted of holding the instrumented handle with the dominant hand at predetermined grip force values. Five subjects took part in the tests. The tests were developed in the absence of vibration and in the presence of vibration at 5 m/s2, 7.5 m/s2 and 10 m/s2. The push and pull force values were calculated in the tests on the five subjects.
- Open Access
- 10 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 9
Comparison of Anti-Vibration Glove Performances in the Laboratory and in the Field: Similarities and Differences
Anti-vibration gloves undergo a certification procedure that is described in the EN ISO 10819:2013. This is a laboratory practice that, in this paper, is compared with a standardized field method. Two methods are implemented in the tests: a direct method and an experimental one. The results show that some transmissibility is above the limit suggested by the standard. The difference between the transmissibility measured in the field, using the direct transmissibility as a reference, and the values declared by the manufacturers is very small. In the case of the experimental transmissibility, two out of three gloves amplify vibrations instead of reducing them.
- 10 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 9
Open AccessComparison of Anti-Vibration Glove Performances in the Laboratory and in the Field: Similarities and Differences
Anti-vibration gloves undergo a certification procedure that is described in the EN ISO 10819:2013. This is a laboratory practice that, in this paper, is compared with a standardized field method. Two methods are implemented in the tests: a direct method and an experimental one. The results show that some transmissibility is above the limit suggested by the standard. The difference between the transmissibility measured in the field, using the direct transmissibility as a reference, and the values declared by the manufacturers is very small. In the case of the experimental transmissibility, two out of three gloves amplify vibrations instead of reducing them.
- Open Access
- 10 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 7
Nonlinearity of Power Absorption Curve and Hand-Arm System Physiology
Models of hand–arm systems (HAS) are purely mechanical. These models do not include the biological active behaviour of the system, even though it has been known since 1997 that there is a tonic vibration reflex. Since then, several authors have investigated this reflex and related it to grip force, posture and some others features of mechanical vibration power absorption. Other scholars proposed models of HAS that do not include the tonic vibration reflex and its consequences. These models, even partial models, are nonetheless effective in describing many aspects of vibration exposure. This is probably due to the complexity of the HAS, so that the confounding factors overwhelm measurements.
- 10 April 2023
- Published by MDPI AG in Proceedings
- Vol. 86 (1) , 7
Open AccessNonlinearity of Power Absorption Curve and Hand-Arm System Physiology
Models of hand–arm systems (HAS) are purely mechanical. These models do not include the biological active behaviour of the system, even though it has been known since 1997 that there is a tonic vibration reflex. Since then, several authors have investigated this reflex and related it to grip force, posture and some others features of mechanical vibration power absorption. Other scholars proposed models of HAS that do not include the tonic vibration reflex and its consequences. These models, even partial models, are nonetheless effective in describing many aspects of vibration exposure. This is probably due to the complexity of the HAS, so that the confounding factors overwhelm measurements.