Ludovic Gavérina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ludovic Gavérina has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Pierre Beauchêne
DMAS, ONERA, Université Paris-Saclay
3 shared publicationsJean-Michel Roche
Paris-Saclay University
2 shared publications- Jean-Michel Roche
DMAS, ONERA, Université Paris-Saclay, Châtillon, France
2 shared publications - Nina Kergosien
DMAS, ONERA, Université Paris-Saclay, F-92322 Châtillon, France
2 shared publications - Olivier Bareille
Ecole Centrale de Lyon
2 shared publications - Olivier Mesnil
Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
2 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by Elsevier in NDT & E International
- Vol. 165
Crack detection on metallic materials fusing flying spot thermography and visible imagery with deep learning
- 3 September 2026
- Published by Elsevier in NDT & E International
- Vol. 165
Open AccessCrack detection on metallic materials fusing flying spot thermography and visible imagery with deep learning
- Open Access
Durability Assessment of Bonded Piezoelectric Wafer Active Sensors for Aircraft Health Monitoring Applications
This study conducted experimental and numerical investigations on piezoelectric wafer active sensors (PWASs) bonded to an aluminum plate to assess the impact of bonding degradation on Lamb wave generation. Three surface-bonded PWASs were examined, including one intentionally bonded with a reduced adhesive to create a defective bond. Thermal cyclic aging was applied, monitoring through laser Doppler vibrometry (LDV) and static capacitance measurements. The PWAS with the initially defective bond exhibited the poorest performance over aging cycles, emphasizing the significance of the initial bond condition. As debonding progressed, modifications in electromechanical behavior were observed, leading to a reduction in wave amplitude and distortion of the generated wave field, challenging the validity of existing analytical modeling of wave-tuning curves for perfectly bonded PWASs. Both numerical simulations and experimental observations substantiated this finding. In conclusion, this study highlights the imperative of a high-integrity bond for the proper functioning of a guided wave-based structural health monitoring (SHM) system, emphasizing ongoing challenges in assessing SHM performance.
Open AccessDurability Assessment of Bonded Piezoelectric Wafer Active Sensors for Aircraft Health Monitoring Applications
This study conducted experimental and numerical investigations on piezoelectric wafer active sensors (PWASs) bonded to an aluminum plate to assess the impact of bonding degradation on Lamb wave generation. Three surface-bonded PWASs were examined, including one intentionally bonded with a reduced adhesive to create a defective bond. Thermal cyclic aging was applied, monitoring through laser Doppler vibrometry (LDV) and static capacitance measurements. The PWAS with the initially defective bond exhibited the poorest performance over aging cycles, emphasizing the significance of the initial bond condition. As debonding progressed, modifications in electromechanical behavior were observed, leading to a reduction in wave amplitude and distortion of the generated wave field, challenging the validity of existing analytical modeling of wave-tuning curves for perfectly bonded PWASs. Both numerical simulations and experimental observations substantiated this finding. In conclusion, this study highlights the imperative of a high-integrity bond for the proper functioning of a guided wave-based structural health monitoring (SHM) system, emphasizing ongoing challenges in assessing SHM performance.
- Open Access
Lead Zirconate Titanate Transducers Embedded in Composite Laminates: The Influence of the Integration Method on Ultrasound Transduction
In the context of an embedded structural health monitoring (SHM) system, two methods of transducer integration into the core of a laminate carbon fiber-reinforced polymer (CFRP) are tested: cut-out and between two plies. This study focuses on the effect of integration methods on Lamb wave generation. For this purpose, plates with an embedded lead zirconate titanate (PZT) transducer are cured in an autoclave. The embedded PZT insulation, integrity, and ability to generate Lamb waves are checked with electromechanical impedance, X-rays, and laser Doppler vibrometry (LDV) measurements. Lamb wave dispersion curves are computed by LDV using two-dimensional fast Fourier transform (Bi-FFT) to study the quasi-antisymmetric mode (qA0) excitability in generation with the embedded PZT in the frequency range of 30 to 200 kHz. The embedded PZT is able to generate Lamb waves, which validate the integration procedure. The first minimum frequency of the embedded PZT shifts to lower frequencies and its amplitude is reduced compared to a surface-mounted PZT.
Open AccessLead Zirconate Titanate Transducers Embedded in Composite Laminates: The Influence of the Integration Method on Ultrasound Transduction
In the context of an embedded structural health monitoring (SHM) system, two methods of transducer integration into the core of a laminate carbon fiber-reinforced polymer (CFRP) are tested: cut-out and between two plies. This study focuses on the effect of integration methods on Lamb wave generation. For this purpose, plates with an embedded lead zirconate titanate (PZT) transducer are cured in an autoclave. The embedded PZT insulation, integrity, and ability to generate Lamb waves are checked with electromechanical impedance, X-rays, and laser Doppler vibrometry (LDV) measurements. Lamb wave dispersion curves are computed by LDV using two-dimensional fast Fourier transform (Bi-FFT) to study the quasi-antisymmetric mode (qA0) excitability in generation with the embedded PZT in the frequency range of 30 to 200 kHz. The embedded PZT is able to generate Lamb waves, which validate the integration procedure. The first minimum frequency of the embedded PZT shifts to lower frequencies and its amplitude is reduced compared to a surface-mounted PZT.
- 16 June 2022
- Published by Springer Nature
- p. 727-736
Thermal Cycling Durability of Bonded PZT Transducers Used for the SHM of Reusable Launch Vehicles
- 16 June 2022
- Published by Springer Nature
- p. 727-736
Thermal Cycling Durability of Bonded PZT Transducers Used for the SHM of Reusable Launch Vehicles
- 15 March 2022
- Published by DEStech Publications
STUDY OF THE EFFECTS OF THERMAL STRESS ON PIEZOELECTRIC SENSORS FOR THE STRUCTURAL HEALTH MONITORING
During the in-service lifetime of an aircraft, the surface bond of any SHM transductor is submitted to thermal stresses, induced by aviation environmental conditions. In this paper, the influence of a disbond, whether willingly introduced or caused by thermal aging, on the ability of a PZT ultrasonic transducer to generate and receive Lamb waves is numerically and experimentally studied.
- 15 March 2022
- Published by DEStech Publications
STUDY OF THE EFFECTS OF THERMAL STRESS ON PIEZOELECTRIC SENSORS FOR THE STRUCTURAL HEALTH MONITORING
During the in-service lifetime of an aircraft, the surface bond of any SHM transductor is submitted to thermal stresses, induced by aviation environmental conditions. In this paper, the influence of a disbond, whether willingly introduced or caused by thermal aging, on the ability of a PZT ultrasonic transducer to generate and receive Lamb waves is numerically and experimentally studied.
- 15 March 2022
- Published by DEStech Publications
OPTIMIZATION OF A STRUCTURAL HEALTH MONITORING SYSTEMS INTEGRATION IN LAMINATED COMPOSITE CURED IN AUTOCLAVE
Composites represent approximately 50% of the weight of structural parts in new aircraft as Airbus 350 or Boeing 787. Damages could occur on these parts and their monitoring is required for the safety of users. A Structural Health Monitoring system composed by a Lamb’s waves generator and a sensor is a privileged candidate to detect such damages. The flexibility of composite manufacturing allows the integration of such a system. The topic of this study is to optimize the integration of a Structural Health Monitoring system in aircraft structural parts. The present article focuses on the optimization of the integration method of a piezoelectric Lead Zirconate Titanate transducer into laminated composite (Carbon/Epoxy), cured in autoclave according to aircraft manufacturing requirements. The health state of the integrated transducer with three connecting methods is evaluated using X-ray scanning. Punctual stress is responsible for the crack of the transducer occurred during composite curing. The connecting method with aluminum sheet and silver joint is selected because it minimizes local stresses and keeps the transducer integrity. The cohesion between the integrated transducer and the host material is observed by optical microscopy, it shows the presence of void zones located in the PZT edges. A Laser Doppler Vibrometer scanning shows the ability of the integrated piezoelectric transducer to generate Lamb waves.
- 15 March 2022
- Published by DEStech Publications
OPTIMIZATION OF A STRUCTURAL HEALTH MONITORING SYSTEMS INTEGRATION IN LAMINATED COMPOSITE CURED IN AUTOCLAVE
Composites represent approximately 50% of the weight of structural parts in new aircraft as Airbus 350 or Boeing 787. Damages could occur on these parts and their monitoring is required for the safety of users. A Structural Health Monitoring system composed by a Lamb’s waves generator and a sensor is a privileged candidate to detect such damages. The flexibility of composite manufacturing allows the integration of such a system. The topic of this study is to optimize the integration of a Structural Health Monitoring system in aircraft structural parts. The present article focuses on the optimization of the integration method of a piezoelectric Lead Zirconate Titanate transducer into laminated composite (Carbon/Epoxy), cured in autoclave according to aircraft manufacturing requirements. The health state of the integrated transducer with three connecting methods is evaluated using X-ray scanning. Punctual stress is responsible for the crack of the transducer occurred during composite curing. The connecting method with aluminum sheet and silver joint is selected because it minimizes local stresses and keeps the transducer integrity. The cohesion between the integrated transducer and the host material is observed by optical microscopy, it shows the presence of void zones located in the PZT edges. A Laser Doppler Vibrometer scanning shows the ability of the integrated piezoelectric transducer to generate Lamb waves.
- 5 January 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (15) , 8279-8287
Integration study among flying spot laser thermography and terahertz technique for the inspection of panel paintings
- 5 January 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (15) , 8279-8287
Integration study among flying spot laser thermography and terahertz technique for the inspection of panel paintings
- Open Access
- 1 January 2019
- Published by QIRT Council
Study and designed of an active infrared system for in-situ characterization of thermal resistance of building envelopes
- 1 January 2019
- Published by QIRT Council
Open AccessStudy and designed of an active infrared system for in-situ characterization of thermal resistance of building envelopes
- 1 August 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 51 (8) , 520-523
Water detection in honeycomb composite structures using terahertz thermography
Experimental results on the detection of latent water in a honeycomb fiberglass structure using terahertz thermography are presented. These data are compared with data that were obtained using active
- 1 August 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 51 (8) , 520-523
Water detection in honeycomb composite structures using terahertz thermography
Experimental results on the detection of latent water in a honeycomb fiberglass structure using terahertz thermography are presented. These data are compared with data that were obtained using active