Luis Cuenca-Dacal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luis Cuenca-Dacal has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ana González-Suárez
Universitat Politècnica de València
2 shared publications - Enrique Berjano
BioMIT, Department of Electronic Engineering, Universitat Politècnica de València
2 shared publications - Juan José Pérez
Dpto de Ing Electronica (7F), Universidad Politecnica de Valencia, Camino de Vera s/n (Edificio 7F), Valencia, 46022, SPAIN
2 shared publications - José M. Lozano
Arrhythmias Unit, Cardiology Department, Hospital Universitario Clínico San Cecilio, 18016 Granada, Spain
1 shared publication - Maite Izquierdo
Electrophysiology Unit, Cardiology Department, Hospital Universitario y Politécnico La Fe de Valencia, 46026 Valencia, Spain
1 shared publication - Marcela Mercado Montoya
IN SILICO STEM S.A.S.
1 shared publication
Latest Publications
- Open Access
- 24 July 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 283
Impact of Intrapericardial Fluid on Lesion Size During Epicardial Radiofrequency Ablation: A Computational Study
Background and aims: Epicardial RFA is often required when ventricular tachyarrhythmias originate from epicardial or subepicardial substrates that cannot be effectively ablated endocardially. Our objective was to evaluate the impact of intrapericardial fluid accumulation on the lesion size in the myocardium and the extent of thermal damage to adjacent structures, particularly the lung. Methods: An in silico model of epicardial RFA was developed, featuring an irrigated-tip catheter placed horizontally on the epicardium. A 50 W–30 s RF pulse was simulated. Temperature distributions and resultant thermal lesions in both the myocardium and lung were computed. Results: An increase in pericardial space from 2.5 mm to 4.5 mm resulted in a reduction of myocardial lesion depth by up to 1 mm, while the volume of lung damage decreased from 200 to 300 mm3 to nearly zero, irrespective of myocardial or epicardial fat thickness. Myocardial lesion size was markedly influenced by the thickness of the epicardial fat layer. In the absence of fat and with a narrow pericardial space, lesions reached up to 262 mm3 in volume and 6.1 mm in depth. With 1 mm of fat, lesion volume decreased to below 100 mm3 and depth to 3 mm; with 2 mm, to under 40 mm3 and 2 mm; and with 3 mm, to less than 16 mm3 and 1.2 mm. Lung damage increased moderately with greater fat thickness. Cooling the irrigation fluid from 37 °C to 5 °C reduced lung damage by up to 51%, while myocardial lesion size decreased by only 15%. Conclusions: Intrapericardial fluid accumulation can limit myocardial lesion formation while protecting adjacent structures. Cooling the irrigation fluid may reduce collateral damage without compromising myocardial lesion depth.
- 24 July 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 283
Open AccessImpact of Intrapericardial Fluid on Lesion Size During Epicardial Radiofrequency Ablation: A Computational Study
Background and aims: Epicardial RFA is often required when ventricular tachyarrhythmias originate from epicardial or subepicardial substrates that cannot be effectively ablated endocardially. Our objective was to evaluate the impact of intrapericardial fluid accumulation on the lesion size in the myocardium and the extent of thermal damage to adjacent structures, particularly the lung. Methods: An in silico model of epicardial RFA was developed, featuring an irrigated-tip catheter placed horizontally on the epicardium. A 50 W–30 s RF pulse was simulated. Temperature distributions and resultant thermal lesions in both the myocardium and lung were computed. Results: An increase in pericardial space from 2.5 mm to 4.5 mm resulted in a reduction of myocardial lesion depth by up to 1 mm, while the volume of lung damage decreased from 200 to 300 mm3 to nearly zero, irrespective of myocardial or epicardial fat thickness. Myocardial lesion size was markedly influenced by the thickness of the epicardial fat layer. In the absence of fat and with a narrow pericardial space, lesions reached up to 262 mm3 in volume and 6.1 mm in depth. With 1 mm of fat, lesion volume decreased to below 100 mm3 and depth to 3 mm; with 2 mm, to under 40 mm3 and 2 mm; and with 3 mm, to less than 16 mm3 and 1.2 mm. Lung damage increased moderately with greater fat thickness. Cooling the irrigation fluid from 37 °C to 5 °C reduced lung damage by up to 51%, while myocardial lesion size decreased by only 15%. Conclusions: Intrapericardial fluid accumulation can limit myocardial lesion formation while protecting adjacent structures. Cooling the irrigation fluid may reduce collateral damage without compromising myocardial lesion depth.
- Open Access
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study
Background: Preclinical studies on radiofrequency (RF) cardiac ablation (RFCA) use very small temperature sensors in specific positions in the tissue subjected to RF heating. Despite the sensors’ small size, the proximity to the ablation electrode and the extremely high thermal gradient around the electrode means that the presence of the temperature sensors could distort the temperatures recorded. Our objective was to assess the thermal impact of intra-tissue temperature sensors during RFCA. Methods: 3D RFCA models were built including different temperature sensors based on fiber optics and T-type thermocouples. Constant power ablation was simulated for 10 s. Results: The results showed that the disturbance caused by the presence of the T-type thermocouples was considerably greater (one order of magnitude) than that caused by the optical fibers. The closer the sensor was to the ablation electrode, the greater the greater the disturbance was and the more it increased with time in sensors more than 3 mm deep. The fiber optic measurements always slightly underestimated (Conclusions: The presence of thermocouples inserted into the tissue close to the RF ablation electrode involves a disturbance that could affect the measured temperature value, although it does not substantially alter the shape and size of the thermal lesion. Optical fibers cause much less disturbance, possibly due to the absence of internal metal parts that favor heat conduction.
Open AccessDisturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study
Background: Preclinical studies on radiofrequency (RF) cardiac ablation (RFCA) use very small temperature sensors in specific positions in the tissue subjected to RF heating. Despite the sensors’ small size, the proximity to the ablation electrode and the extremely high thermal gradient around the electrode means that the presence of the temperature sensors could distort the temperatures recorded. Our objective was to assess the thermal impact of intra-tissue temperature sensors during RFCA. Methods: 3D RFCA models were built including different temperature sensors based on fiber optics and T-type thermocouples. Constant power ablation was simulated for 10 s. Results: The results showed that the disturbance caused by the presence of the T-type thermocouples was considerably greater (one order of magnitude) than that caused by the optical fibers. The closer the sensor was to the ablation electrode, the greater the greater the disturbance was and the more it increased with time in sensors more than 3 mm deep. The fiber optic measurements always slightly underestimated (Conclusions: The presence of thermocouples inserted into the tissue close to the RF ablation electrode involves a disturbance that could affect the measured temperature value, although it does not substantially alter the shape and size of the thermal lesion. Optical fibers cause much less disturbance, possibly due to the absence of internal metal parts that favor heat conduction.