Yiyang Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yiyang Meng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yanding Qin
Nankai University
3 shared publications - Jianda Han
Nankai University
2 shared publications - Mengde Luo
College of Artificial Intelligence, Nankai University, Tianjin, China
2 shared publications - Pengxiu Geng
College of Artificial Intelligence, Nankai University, Tianjin, China
2 shared publications Hongpeng Wang
Nankai University,College of Artificial Intelligence (Tianjin Key Laboratory of Intelligent Robotics),Tianjin,China,300350
1 shared publicationYugen You
Nankai University,College of Artificial Intelligence (Tianjin Key Laboratory of Intelligent Robotics),Tianjin,China,300350
1 shared publication
Latest Publications
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
An Occlusion-Free Intraoperative Active Navigation System for Orthopedic Surgery
Intraoperative optical tracking system (OTS) suffers from the visual occlusion problem when an obstacle blocks the visual cone (VC) of the OTS. In this paper, angle and distance margins are proposed to quantify the degree of danger of an obstacle based on its spatial relationship to the VCs of the OTS. Based on this mathematical modeling, an active navigation system is proposed, where the navigation robot is used to adjust the pose of the OTS before occlusion occurs. Circular and translational trajectories are proposed as basic adjusting trajectories for the OTS. A dual-step optimization is then established to find the optimal observation pose of the OTS and plan an occlusion-free adjusting trajectory for the navigation robot. Finally, simulations and experiments are conducted to validate the effectiveness of the proposed method. The results demonstrate that the proposed method effectively keeps the VCs of the OTS away from the moving path of the obstacle, and thus maintaining consistent navigation. This active navigation method is promising for the safe operations of surgical systems employing optical navigation.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
An Occlusion-Free Intraoperative Active Navigation System for Orthopedic Surgery
Intraoperative optical tracking system (OTS) suffers from the visual occlusion problem when an obstacle blocks the visual cone (VC) of the OTS. In this paper, angle and distance margins are proposed to quantify the degree of danger of an obstacle based on its spatial relationship to the VCs of the OTS. Based on this mathematical modeling, an active navigation system is proposed, where the navigation robot is used to adjust the pose of the OTS before occlusion occurs. Circular and translational trajectories are proposed as basic adjusting trajectories for the OTS. A dual-step optimization is then established to find the optimal observation pose of the OTS and plan an occlusion-free adjusting trajectory for the navigation robot. Finally, simulations and experiments are conducted to validate the effectiveness of the proposed method. The results demonstrate that the proposed method effectively keeps the VCs of the OTS away from the moving path of the obstacle, and thus maintaining consistent navigation. This active navigation method is promising for the safe operations of surgical systems employing optical navigation.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Optimization Scheme for Online Viewpoint Planning of Active Optical Navigation System in Orthopedic Surgeries
Optical tracking system (OTS) is widely used in robot orthopedic surgeries. During the surgery, the locomotion of the surgical instrument along different osteotomy planes and the adjustment of the patient’s body will lead to obvious variations on the spatial relationship among the positioning tools. Usually, the OTS is manually placed at a fixed viewpoint. As the size of the measurement volume (MV) of the OTS is limited, some positioning tools might move towards the boundaries of the MV, increasing the risk of navigation failure. This paper proposes a two-phase optimization scheme for the active online adjusting of the OTS viewpoint to guarantee the consistency of navigation. A novel optimization structure is proposed with the consideration of continuous state inequality constraints. The dynamic accuracy of the OTS during the active adjusting is also demonstrated to be reliable. Ultimately, simulations and experiments are performed on an active navigation system to verify the effectiveness of the proposed two-phase optimization scheme. Experimental results show that the OTS can be moved to the optimal viewpoint smoothly when confronted with significant variations on the spatial relationship among the positioning tools, guaranteeing the consistency of navigation. The navigation robot successfully keeps the positioning tools around the central region of the MV at different surgical phases.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Optimization Scheme for Online Viewpoint Planning of Active Optical Navigation System in Orthopedic Surgeries
Optical tracking system (OTS) is widely used in robot orthopedic surgeries. During the surgery, the locomotion of the surgical instrument along different osteotomy planes and the adjustment of the patient’s body will lead to obvious variations on the spatial relationship among the positioning tools. Usually, the OTS is manually placed at a fixed viewpoint. As the size of the measurement volume (MV) of the OTS is limited, some positioning tools might move towards the boundaries of the MV, increasing the risk of navigation failure. This paper proposes a two-phase optimization scheme for the active online adjusting of the OTS viewpoint to guarantee the consistency of navigation. A novel optimization structure is proposed with the consideration of continuous state inequality constraints. The dynamic accuracy of the OTS during the active adjusting is also demonstrated to be reliable. Ultimately, simulations and experiments are performed on an active navigation system to verify the effectiveness of the proposed two-phase optimization scheme. Experimental results show that the OTS can be moved to the optimal viewpoint smoothly when confronted with significant variations on the spatial relationship among the positioning tools, guaranteeing the consistency of navigation. The navigation robot successfully keeps the positioning tools around the central region of the MV at different surgical phases.
- 27 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1755-1760
Development of an Intra-Operative Active Navigation System for Robot-Assisted Surgery
Optical tracking system (OTS), an essential component of robot-assisted surgery, measures the position and orientation of the surgical tools during surgery operations. OTS has proven to be a reliable intra-operative navigation method in clinical applications. However, OTS suffers from the vision occlusion where obstacles block the vision of the position sensors of the OTS. To tackle with this problem, we propose an active navigation system which can automatically moves the OTS so as to avoid the occlusion and meanwhile maintain the tracking accuracy. The active navigation system is composed of a multi-DOF robot, an optical tracker and an RGB-D camera. The accuracy of OTS is influenced by several factors, such as working distance and relative orientation of the tracked tool. Since in the active navigation system, the OTS moves during navigation, the impact of the movement of OTS on its accuracy is investigated. The corresponding experiments are conducted, and the results are analyzed. Subsequently, an occlusion avoidance strategy is developed to control the OTS to not only avoid the obstacles but also keep the accuracy degradation acceptable. Ultimately, the occlusion avoidance experiment is conducted to verify the proposed strategy. The experimental results demonstrate the effectiveness of the proposed active navigation system.
- 27 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1755-1760
Development of an Intra-Operative Active Navigation System for Robot-Assisted Surgery
Optical tracking system (OTS), an essential component of robot-assisted surgery, measures the position and orientation of the surgical tools during surgery operations. OTS has proven to be a reliable intra-operative navigation method in clinical applications. However, OTS suffers from the vision occlusion where obstacles block the vision of the position sensors of the OTS. To tackle with this problem, we propose an active navigation system which can automatically moves the OTS so as to avoid the occlusion and meanwhile maintain the tracking accuracy. The active navigation system is composed of a multi-DOF robot, an optical tracker and an RGB-D camera. The accuracy of OTS is influenced by several factors, such as working distance and relative orientation of the tracked tool. Since in the active navigation system, the OTS moves during navigation, the impact of the movement of OTS on its accuracy is investigated. The corresponding experiments are conducted, and the results are analyzed. Subsequently, an occlusion avoidance strategy is developed to control the OTS to not only avoid the obstacles but also keep the accuracy degradation acceptable. Ultimately, the occlusion avoidance experiment is conducted to verify the proposed strategy. The experimental results demonstrate the effectiveness of the proposed active navigation system.