Krisada Auepattana-Aumrung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krisada Auepattana-Aumrung has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Crespy
Department of Materials Science and Engineering School of Molecular Science and Engineering Vidyasirimedhi Institute of Science and Technology VISTEC Rayong Thailand
2 shared publications - Chalunda Tirayaphanitchkul
Department of Chemical Engineering, School of Energy Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand
1 shared publication - Hans-Jürgen Butt
Max Planck Institute for Polymer Research, Mainz, Germany
1 shared publication - Makoto Ogawa
School of Energy Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), 555 Moo 1 Payupnai, Wangchan, Rayong 21210, Thailand
1 shared publication - Rüdiger Berger
Max Planck Institute for Polymer Research Mainz Germany
1 shared publication - Xiaomei Li
Max Planck Institute for Polymer Research Ackermannweg 10 55128 Mainz Germany
1 shared publication
Latest Publications
- 2 February 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (4) , 2129-2138
Responsive Polymer-Layered Silicate Hybrids for Anticorrosion
- 2 February 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (4) , 2129-2138
Responsive Polymer-Layered Silicate Hybrids for Anticorrosion
- Open Access
- 11 April 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (14) , 144901
Fast-release kinetics of a pH-responsive polymer detected by dynamic contact angles
Polymers conjugated with active agents have applications in biomedicine, anticorrosion, and smart agriculture. When the active agent is used as a drug, corrosion inhibitor, or pesticide, it can be released upon a specific stimulus. The efficiency and the sustainability of active agents are determined by the released kinetics. In this work, we study the fast-release kinetics of 8-hydroxyquinoline (8HQ) from a pH-responsive, random copolymer of methyl methacrylate and 8-quinolinyl-sulfide-ethyl acrylate [P(MMA-co-HQSEA)] by hydrolysis of the β-thiopropionate groups. We used contact angle measurements of sliding drops as an elegant way to characterize the release kinetics. Based on the results gained from 1H nuclear magnetic resonance measurement, fluorescent intensity measurement, and velocity-dependent contact angle measurement, we found that both the hydrolysis rate and polymer conformation affect the release kinetics of 8HQ from a P(MMA-co-HQSEA) film. Polymer chains collapse and further suppress the release from the inner layer in acidic conditions, while polymer chains in a stretched condition further facilitate the release from the inner layer. As a result, the cumulative release rate of 8HQ is higher in the basic condition than in the acidic condition.
- 11 April 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (14) , 144901
Open AccessFast-release kinetics of a pH-responsive polymer detected by dynamic contact angles
Polymers conjugated with active agents have applications in biomedicine, anticorrosion, and smart agriculture. When the active agent is used as a drug, corrosion inhibitor, or pesticide, it can be released upon a specific stimulus. The efficiency and the sustainability of active agents are determined by the released kinetics. In this work, we study the fast-release kinetics of 8-hydroxyquinoline (8HQ) from a pH-responsive, random copolymer of methyl methacrylate and 8-quinolinyl-sulfide-ethyl acrylate [P(MMA-co-HQSEA)] by hydrolysis of the β-thiopropionate groups. We used contact angle measurements of sliding drops as an elegant way to characterize the release kinetics. Based on the results gained from 1H nuclear magnetic resonance measurement, fluorescent intensity measurement, and velocity-dependent contact angle measurement, we found that both the hydrolysis rate and polymer conformation affect the release kinetics of 8HQ from a P(MMA-co-HQSEA) film. Polymer chains collapse and further suppress the release from the inner layer in acidic conditions, while polymer chains in a stretched condition further facilitate the release from the inner layer. As a result, the cumulative release rate of 8HQ is higher in the basic condition than in the acidic condition.