Breno Oliveira Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Breno Oliveira Almeida has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Guy F. A. Prado
Hospital Israelita Albert Einstein
3 shared publications - José Mariani Junior
Hospital Israelita Albert Einstein
3 shared publications - Pedro Alves Lemos
Hospital Israelita Albert Einstein
3 shared publications - Stefano Garzon
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
3 shared publications - Adriano Caixeta
Postgraduate Program in Cardiology, Universidade Federal de São Paulo (UNIFESP), São Paulo 04024-000, SP, Brazil
2 shared publications - Carlos Alberto Bulant
National Laboratory for Scientific Computing, LNCC/MCTIC, Av. Getúlio Vargas, 333, Petrópolis-RJ, 25651-075, Brazil
1 shared publication
Latest Publications
- Open Access
- 23 October 2025
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 23, eAO1592
Thin-cap fibroatheroma association with local inflammatory activity in coronary disease: an optical-coherence tomography study
Highlights ■ Optical coherence tomography enables in vivo characterization of inflammatory activity within coronary plaques. ■ Thin-cap fibroatheromas demonstrate greater macrophage accumulation than non-thin-cap fibroatheromas. ■ Neovascularization is more frequent and quantitatively greater in thin-cap fibroatheromas. ■ The combined burden of macrophages and neovessels provides predictive value for plaque vulnerability. ABSTRACT Objective: The aim of the present study is to assess whether the intensity of local inflammation relates to the presence of thin-cap fibroatheromas. Methods: Retrospective, single-center study of patients
- 23 October 2025
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 23, eAO1592
Open AccessThin-cap fibroatheroma association with local inflammatory activity in coronary disease: an optical-coherence tomography study
Highlights ■ Optical coherence tomography enables in vivo characterization of inflammatory activity within coronary plaques. ■ Thin-cap fibroatheromas demonstrate greater macrophage accumulation than non-thin-cap fibroatheromas. ■ Neovascularization is more frequent and quantitatively greater in thin-cap fibroatheromas. ■ The combined burden of macrophages and neovessels provides predictive value for plaque vulnerability. ABSTRACT Objective: The aim of the present study is to assess whether the intensity of local inflammation relates to the presence of thin-cap fibroatheromas. Methods: Retrospective, single-center study of patients
- Open Access
- 23 June 2023
- Published by Taylor & Francis in Renal Failure
- Vol. 45 (1) , 2224888
Zero-contrast imaging for the assessment of transcatheter aortic valve implantation in candidates with renal dysfunction
Candidates for transcatheter aortic valve implantation (TAVI) are currently evaluated using computed tomography angiography and invasive cardiac catheterization as an essential part of case selection and pre-procedure interventional planning. However, both imaging methods utilize iodinated agents, which may cause contrast-induced nephropathy, particularly in patients with baseline renal dysfunction. This study aimed to describe a zero-contrast imaging protocol for pre-TAVI evaluation in patients with advanced renal impairment. The pre-TAVI zero-contrast scheme consisted of the following multi-modality combinations: (1) gadolinium-free magnetic resonance imaging (three-dimensional navigator-echo with electrocardiogram-gated steady-state free-precession series); (2) iodinated-free multislice computed tomography electrocardiogram-gated; (3) lower limb arterial duplex scan ultrasound; and (4) transesophageal echocardiography. Ultimately, TAVI was performed for those deemed good candidates, and contrast was allowed during the intervention; however, operators were strongly advised to utilize the least volume possible of iodinated agents. This pilot survey included ten patients with symptomatic aortic stenosis and renal dysfunction who underwent zero-contrast multi-modality imaging. All the patients ultimately underwent TAVI. The intervention was successful in all cases, without ≥ moderate residual aortic regurgitation, prosthesis embolization, annulus rupture, major vascular complications, stroke, or death during index hospitalization. The creatinine clearance remained stable throughout the observation period (baseline: 26.85 ± 12.55 mL/min; after multi-modality imaging: 26.76 ± 11.51 mL/min; post-TAVI at discharge: 29.84 ± 13.98 mL/min; p = 0.3 all). The proposed contrast-free imaging protocol appears to be a promising clinical tool for pre-TAVI evaluation in patients with severe renal dysfunction.
- 23 June 2023
- Published by Taylor & Francis in Renal Failure
- Vol. 45 (1) , 2224888
Open AccessZero-contrast imaging for the assessment of transcatheter aortic valve implantation in candidates with renal dysfunction
Candidates for transcatheter aortic valve implantation (TAVI) are currently evaluated using computed tomography angiography and invasive cardiac catheterization as an essential part of case selection and pre-procedure interventional planning. However, both imaging methods utilize iodinated agents, which may cause contrast-induced nephropathy, particularly in patients with baseline renal dysfunction. This study aimed to describe a zero-contrast imaging protocol for pre-TAVI evaluation in patients with advanced renal impairment. The pre-TAVI zero-contrast scheme consisted of the following multi-modality combinations: (1) gadolinium-free magnetic resonance imaging (three-dimensional navigator-echo with electrocardiogram-gated steady-state free-precession series); (2) iodinated-free multislice computed tomography electrocardiogram-gated; (3) lower limb arterial duplex scan ultrasound; and (4) transesophageal echocardiography. Ultimately, TAVI was performed for those deemed good candidates, and contrast was allowed during the intervention; however, operators were strongly advised to utilize the least volume possible of iodinated agents. This pilot survey included ten patients with symptomatic aortic stenosis and renal dysfunction who underwent zero-contrast multi-modality imaging. All the patients ultimately underwent TAVI. The intervention was successful in all cases, without ≥ moderate residual aortic regurgitation, prosthesis embolization, annulus rupture, major vascular complications, stroke, or death during index hospitalization. The creatinine clearance remained stable throughout the observation period (baseline: 26.85 ± 12.55 mL/min; after multi-modality imaging: 26.76 ± 11.51 mL/min; post-TAVI at discharge: 29.84 ± 13.98 mL/min; p = 0.3 all). The proposed contrast-free imaging protocol appears to be a promising clinical tool for pre-TAVI evaluation in patients with severe renal dysfunction.
- 5 April 2023
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (6) , 1036-1044
Quantitative coronary three‐dimensional geometry and its association with atherosclerotic disease burden and composition
Background: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three‐dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD).Methods: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS‐VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length‐based; (ii) curvature‐based, torsion‐based, and curvature/torsion‐combined; (iii) vessel path‐based. The geometric variables were compared with IVUS‐VH parameters assessing the extent and composition of coronary atherosclerosis.Results: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS‐VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS‐VH parameters even after multivariate adjustment for clinical characteristics.Conclusions: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.
- 5 April 2023
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (6) , 1036-1044
Quantitative coronary three‐dimensional geometry and its association with atherosclerotic disease burden and composition
Background: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three‐dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD).Methods: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS‐VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length‐based; (ii) curvature‐based, torsion‐based, and curvature/torsion‐combined; (iii) vessel path‐based. The geometric variables were compared with IVUS‐VH parameters assessing the extent and composition of coronary atherosclerosis.Results: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS‐VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS‐VH parameters even after multivariate adjustment for clinical characteristics.Conclusions: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.