Mustafa Musa Jaber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Musa Jaber has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Amara Dar
School of Chemistry, University of the Punjab, Lahore, Pakistan
1 shared publication - Ghufrana Samin
Department of Basic Sciences and Humanities, University of Engineering and Technology, Faisalabad campus, Pakistan
1 shared publication Jamil Anwar
Centre for Analytical Chemistry, School of Chemistry, University of the Punjab, Quaid-e-Azam Campus, Lahore 54590, Pakistan
1 shared publication- Muhammad Muzammil Jahangir
Institute of Horticultural Sciences, University of Agriculture, Faisalabad, Pakistan
1 shared publication Muhammad Nayab Ahmad
Centre for Analytical Chemistry, School of Chemistry, University of the Punjab, Quaid-e-Azam Campus, Lahore 54590, Pakistan
1 shared publication- Rabia Rehman
School of Chemistry, University of the Punjab, Lahore, Pakistan
1 shared publication
Latest Publications
- Open Access
- 12 April 2023
- Published by Hindawi Limited in International Journal of Analytical Chemistry
- Vol. 2023, 1-6
Separation of Amino Acids, Dyes, and Pigments Using Novel Pressurized Circular TLC Assembly for Secure Medical Imaging Applications
A novel pressurized flow system for circular thin-layer chromatography (PC-TLC) has been successfully established and employed for the separation of amino acids, dyes, and pigments for safe medical imaging applications. In this system, the mobile phase is applied to a regular TLC plate through the tube and needle of an intravenous infusion set. The needle was fused in a hole underneath the center of the plate, while the second side end of the tube was connected to a microburette containing the solvent. This new assembly proved itself better in terms of separation time (within 5minutes) and controlled flow of the solvent and horizontal movement of analyte components over chromatograms with better separation and Rf values (glutamine: 0.26, valine: 0.44, phenylalanine: 0.60, chlorophyll a: 0.52, chlorophyll b: 0.43, xanthophyll: 0.18, carotenoid: 0.97, and pheophytin: 0.60) when a number of samples of amino acids, dyes, and pigments were separated by the developed apparatus and the conventional TLC procedure. The developed method was found distinctly rapid, precise, and eco-friendly (less solvent consuming) as compared to traditional ascending TLC.
- 12 April 2023
- Published by Hindawi Limited in International Journal of Analytical Chemistry
- Vol. 2023, 1-6
Open AccessSeparation of Amino Acids, Dyes, and Pigments Using Novel Pressurized Circular TLC Assembly for Secure Medical Imaging Applications
A novel pressurized flow system for circular thin-layer chromatography (PC-TLC) has been successfully established and employed for the separation of amino acids, dyes, and pigments for safe medical imaging applications. In this system, the mobile phase is applied to a regular TLC plate through the tube and needle of an intravenous infusion set. The needle was fused in a hole underneath the center of the plate, while the second side end of the tube was connected to a microburette containing the solvent. This new assembly proved itself better in terms of separation time (within 5minutes) and controlled flow of the solvent and horizontal movement of analyte components over chromatograms with better separation and Rf values (glutamine: 0.26, valine: 0.44, phenylalanine: 0.60, chlorophyll a: 0.52, chlorophyll b: 0.43, xanthophyll: 0.18, carotenoid: 0.97, and pheophytin: 0.60) when a number of samples of amino acids, dyes, and pigments were separated by the developed apparatus and the conventional TLC procedure. The developed method was found distinctly rapid, precise, and eco-friendly (less solvent consuming) as compared to traditional ascending TLC.