Maimonah Alali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maimonah Alali has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Abdulaziz Ali Ahmed Alhazmi
Intern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia
1 shared publication - Abdullah Hasan Alshehri
Department of Prosthodontics, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
1 shared publication - Abrar A. Ageeli
Dental Director Center and Specialty Dental Center, Ministry of Health, Dental Public Health, Jazan, Saudi Arabia
1 shared publication - Ahid Amer Alshahrani
Department of Dental Technology, Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
1 shared publication - Alhanouf K. Alnajdi
Intern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia
1 shared publication - Areej Hakami
General Dentist, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 30 December 2023
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e943404-e943404-16
Influence of Chairside Simulated Adjustment (Finishing and Polishing) Protocol and Chlorhexidine Mouthwash Immersion on Color Stability and Translucency of 2 and 3 Preshaded Multilayered Monolithic Zirconia
Background: Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. Material/Methods: Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (Delta E) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. Results: NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (Delta E=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. Conclusions: ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.
- 30 December 2023
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e943404-e943404-16
Open AccessInfluence of Chairside Simulated Adjustment (Finishing and Polishing) Protocol and Chlorhexidine Mouthwash Immersion on Color Stability and Translucency of 2 and 3 Preshaded Multilayered Monolithic Zirconia
Background: Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. Material/Methods: Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (Delta E) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. Results: NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (Delta E=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. Conclusions: ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.
- Open Access
- 14 April 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (2) , 157
Effects of Blood Contamination and Decontamination Protocol on Reverse Torque Value of Abutment Screws in Dental Implants: An In Vitro Study
Background and Objective: Loosening of abutment screws in dental implants is a mechanical complication that affects prosthetic treatments and hence, patient satisfaction. Blood contamination of abutment screws may play a role in this phenomenon. However, only limited research attention has been given to this issue. In the present study, we determined the effect of blood contamination and decontamination protocol on the reverse torque value (RTV) of abutment screws. Materials and Methods: A questionnaire-based survey was sent to 210 implantologists requesting feedback on their attitude to the blood contamination issue and the decontamination protocols used. The survey responses were used in a selection of the decontamination solutions that were used in the subsequent in vitro study on the effects of blood decontamination protocol on the RTV of abutment screws. Thus, three study groups were used (n = 20 abutment screws in each group): Group 1 (control group; blood-contaminated screws); Group 2 (screws decontaminated with 5.25% sodium hypochlorite (NaOCl) solution); and Group 3 (screws decontaminated with normal saline solution (0.9%)). Then, each of the connections were subjected to thermocycling, and RTVs of the screw were measured using a digital torque meter. Intragroup and intergroup RTVs were analyzed for significance using analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) tests. Results: 48% of the implantologists responded to the survey; 80% of them were concerned with blood contamination in the implant connection, especially before abutment loading and 85% of them used either chlorhexidine solution or normal saline solution as the decontamination agent. The mean RTV for Group 2 screws (30.27 ± 2.8 N.cm) was significantly greater than that for Group 3 screws (26.02 ± 1.99 N.cm) which, in turn, was significantly greater than that for Group 1 screws (23.64 ± 1.84 N.cm). Conclusion: Decontamination of blood-covered connections using 5.25% NaOCl solution or normal saline solution restores the RTV of abutment screws. This finding may have clinical relevance in that the decontaminated screws may contribute to the low incidence of screw loosening and, ultimately, improved patient satisfaction.
- 14 April 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (2) , 157
Open AccessEffects of Blood Contamination and Decontamination Protocol on Reverse Torque Value of Abutment Screws in Dental Implants: An In Vitro Study
Background and Objective: Loosening of abutment screws in dental implants is a mechanical complication that affects prosthetic treatments and hence, patient satisfaction. Blood contamination of abutment screws may play a role in this phenomenon. However, only limited research attention has been given to this issue. In the present study, we determined the effect of blood contamination and decontamination protocol on the reverse torque value (RTV) of abutment screws. Materials and Methods: A questionnaire-based survey was sent to 210 implantologists requesting feedback on their attitude to the blood contamination issue and the decontamination protocols used. The survey responses were used in a selection of the decontamination solutions that were used in the subsequent in vitro study on the effects of blood decontamination protocol on the RTV of abutment screws. Thus, three study groups were used (n = 20 abutment screws in each group): Group 1 (control group; blood-contaminated screws); Group 2 (screws decontaminated with 5.25% sodium hypochlorite (NaOCl) solution); and Group 3 (screws decontaminated with normal saline solution (0.9%)). Then, each of the connections were subjected to thermocycling, and RTVs of the screw were measured using a digital torque meter. Intragroup and intergroup RTVs were analyzed for significance using analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) tests. Results: 48% of the implantologists responded to the survey; 80% of them were concerned with blood contamination in the implant connection, especially before abutment loading and 85% of them used either chlorhexidine solution or normal saline solution as the decontamination agent. The mean RTV for Group 2 screws (30.27 ± 2.8 N.cm) was significantly greater than that for Group 3 screws (26.02 ± 1.99 N.cm) which, in turn, was significantly greater than that for Group 1 screws (23.64 ± 1.84 N.cm). Conclusion: Decontamination of blood-covered connections using 5.25% NaOCl solution or normal saline solution restores the RTV of abutment screws. This finding may have clinical relevance in that the decontaminated screws may contribute to the low incidence of screw loosening and, ultimately, improved patient satisfaction.