LJLi-Xue Jiang

Li-Xue Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Li-Xue Jiang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Robotic Sample Handling Platform for Fully Automated Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging

    by Li-Xue Jiang, Emerson Hernly, Benjamin W. Cerjan, Mushfeqa Iqfath, Tommy Zhang, Julia Laskin

    Recent advances in mass spectrometry imaging (MSI) have enabled high-throughput experiments, making it possible to image multiple samples and perform three-dimensional molecular mapping. For these applications, automated sample handling is critical. Here, we present the first fully automated nanospray desorption electrospray ionization (nano-DESI) MSI platform that integrates robotic sample handling with automated sample recognition system. A robotic arm, controlled by our custom LabVIEW program, automatically places samples onto a sample holder and removes them after the analysis. The sample holder, mounted on a motorized XYZ stage, is automatically transferred to a mass spectrometer for imaging. A newly developed on-site sample region recognition system enables on-the-fly identification of sample coordinates and transfers them to LabVIEW, which plans and executes the imaging experiment. A microfluidic nano-DESI probe (MFP) was used due to its robustness and high-throughput capability. Shear force feedback distance control was incorporated into the MFP to address height variations across multiple glass slides. Using this system, five mouse brain tissue sections on two glass slides were imaged sequentially with high reproducibility and consistency, without human intervention. These results demonstrate the feasibility and performance of a fully automated nano-DESI MSI workflow, paving the way for multisample and three-dimensional MSI experiments.


  • Open Access

    Rational design of polycationic, biodegradable nanogels for intracellular siRNA delivery to microglia

    by Rachel A. Aguillard, Paige I. Radloff, Maryam Paykar, Serenity S. Howery, Maia Lopez Yurrita, Li-Xue Jiang, Nicholas A. Peppas

    Dual-responsive nanogels were engineered by varying hydrophilic/hydrophobic composition and incorporating disulfide crosslinkers to tune degradable architecture optimized for intracellular siRNA accumulation in microglia with biocompatibility.

  • Isomer-Selective Mass Spectrometry Imaging Using Nanospray Desorption Electrospray Ionization (Nano-DESI)

    by Sara Amer, Li-Xue Jiang, Mushfeqa Iqfath, Miranda R. Weigand, Julia Laskin

    ConspectusMass spectrometry imaging (MSI) has transformed our ability to explore molecular distributions in biological tissues with high chemical specificity and sensitivity. Despite significant advances in this field, the absence of separation prior to analysis leads to isomeric and isobaric overlaps, posing a major analytical challenge. To enhance chemical specificity and enable isomer differentiation, tandem mass spectrometry, ion mobility spectrometry, chemical complexation, and derivatization strategies are increasingly integrated into MSI workflows.Ambient ionization MSI techniques provide both chemical and spatial information under native or near-native conditions, enabling rapid, label-free molecular imaging of complex biological samples with minimal sample pretreatment. Among the most promising ambient MSI techniques is nanospray desorption electrospray ionization (nano-DESI), a method that relies on localized liquid extraction directly from biological tissue sections. We have successfully implemented custom-designed nano-DESI platforms on multiple commercial mass spectrometers to enable molecular identification at each pixel of the image and facilitate isomer-selective mass spectrometry imaging (iMSI).This Account highlights recent advances in iMSI using nano-DESI. Key developments include the integration of nano-DESI with multiple reaction monitoring on a triple quadrupole mass spectrometer to differentiate isomeric lipids in biological tissues. We also describe the integration of photoinitiated derivatization and metal ion complexation strategies to enable isomer-selective imaging using structure-specific fragments generated by collision induced dissociation. Furthermore, high-resolution separation of lipid isomers was achieved by coupling nano-DESI with trapped ion mobility spectrometry, demonstrating the value of gas-phase separation for iMSI. These innovations have significantly expanded the analytical capabilities of MSI critical to probing the spatial organization of isomeric lipids and metabolites in biological systems. We also discuss future directions, including new complexation strategies and the integration of nano-DESI with data-independent acquisition and parallel accumulation serial fragmentation technologies. Collectively, these advances establish nano-DESI iMSI as a powerful and versatile tool in the evolving field of spatial metabolomics and lipidomics.


  • Constant Distance Mode Mass Spectrometry Imaging with a Confocal Sensor

    by Tommy Zhang, Ryan T. Hilger, Li-Xue Jiang, Julia Laskin


  • High-spatial-resolution mass spectrometry imaging of biological tissues using a microfluidic probe

    by Li-Xue Jiang, Xiangtang Li, Matthias Polack, Detlev Belder, Julia Laskin

    Nanospray desorption electrospray ionization (nano-DESI) is a liquid extraction-based ambient ionization mass spectrometry imaging (MSI) technique that enables quantitative molecular mapping of biological samples in their native state with high spatial resolution. To facilitate the wider adoption of nano-DESI MSI by the scientific community, we have developed a robust and user-friendly microfluidic probe (MFP). The probe has been used to achieve high spatial resolution of 8–10 µm and up to 10-fold improvement in the experimental throughput, enabling imaging of large tissue sections with cellular resolution. Here, we provide detailed instructions for designing, fabricating and operating MFPs. In addition, we describe a complete workflow for nano-DESI MSI, covering every step from probe assembly to data acquisition and analysis. Although the fabrication of MFPs requires expertise in microfluidics and can take a few days, the process can be outsourced to qualified companies for manufacturing. Once the MFP is fabricated, the entire imaging workflow can be completed in several hours, depending on the sample size. For example, a sample with an area of 1 cm² can be analyzed in <10 h at a spatial resolution of 10 µm. The exceptional performance and ease of use of these probes will make high-resolution nano-DESI MSI more accessible to the scientific community.


  • Pneumatically Assisted Microfluidic Probe for Enhanced Mass Spectrometry Imaging Performance

    by Li-Xue Jiang, Julia Laskin

    A pneumatically assisted microfluidic probe (MFP) with two microfluidic channels has been developed for nanospray desorption electrospray ionization mass spectrometry imaging (nano-DESI MSI) of biological samples. This design simplifies the experimental setup, making it independent of the vacuum suction at the mass spectrometer inlet. The implementation of pneumatically assisted solvent flow through the probe enables stable, high solvent flow rates required to maintain a consistent liquid bridge during high-throughput MSI experiments. This approach addresses challenges associated with using MFP nano-DESI probes on mass spectrometers that have limited vacuum suction and the operation of MFPs with small microfluidic channels. We demonstrate the robustness of the pneumatically assisted MFP with 30 μm channels, which cannot be used for high-throughput MSI experiments without pneumatic assistance, by successfully imaging five mouse brain tissue sections without interruptions.


  • Open Access

    Hardware and software solutions for implementing nanospray desorption electrospray ionization (nano‐DESI) sources on commercial mass spectrometers

    by Li‐Xue Jiang, Ryan T. Hilger, Julia Laskin

    Nanospray desorption electrospray ionization (nano‐DESI) is an ambient ionization mass spectrometry imaging (MSI) approach that enables spatial mapping of biological and environmental samples with high spatial resolution and throughput. Because nano‐DESI has not yet been commercialized, researchers develop their own sources and interface them with different commercial mass spectrometers. Previously, several protocols focusing on the fabrication of nano‐DESI probes have been reported. In this tutorial, we discuss different hardware requirements for coupling the nano‐DESI source to commercial mass spectrometers, such as the safety interlock, inlet extension, and contact closure. In addition, we describe the structure of our custom software for controlling the nano‐DESI MSI platform and provide detailed instructions for its usage. With this tutorial, interested researchers should be able to implement nano‐DESI experiments in their labs.


  • Open Access

    Hardware and software solutions for implementing nanospray desorption electrospray ionization (nano-DESI) sources on commercial mass spectrometers

    by Lixue Jiang, Ryan Hilger, Julia Laskin

    Nanospray desorption electrospray ionization (nano-DESI) is an ambient ionization mass spectrometry imaging (MSI) approach that has been used for imaging of biological and environmental samples with high spatial resolution and throughput. Because nano-DESI has not yet been commercialized, researchers develop their own sources and interface them with different commercial mass spectrometers. Previously, several protocols focusing on the fabrication of nano-DESI probes have been reported. In this tutorial, we discuss different hardware requirements for coupling the nano-DESI source to commercial mass spectrometers, such as the safety interlock, inlet extension, and contact closure. In addition, we describe the structure of our custom software for controlling the nano-DESI MSI platform and provide detailed instructions for its usage. With this tutorial, interested researchers should be able to implement nano-DESI experiments in their own labs.

  • Open Access

    A monolithic microfluidic probe for ambient mass spectrometry imaging of biological tissues

    by Li-Xue Jiang, Matthias Polack, Xiangtang Li, Manxi Yang, Detlev Belder, Julia Laskin

    Novel laser-assisted etching of a fused silica microfluidic probe for liquid extraction-based ambient mass spectrometry imaging.


  • Nanospray Desorption Electrospray Ionization (Nano-DESI) Mass Spectrometry Imaging with High Ion Mobility Resolution

    by Li-Xue Jiang, Emerson Hernly, Hang Hu, Ryan T. Hilger, Heiko Neuweger, Manxi Yang, Julia Laskin

    Untargeted separation of isomeric and isobaric species in mass spectrometry imaging (MSI) is challenging. The combination of ion mobility spectrometry (IMS) with MSI has emerged as an effective strategy for differentiating isomeric and isobaric species, which substantially enhances the molecular coverage and specificity of MSI experiments. In this study, we have implemented nanospray desorption electrospray ionization (nano-DESI) MSI on a trapped ion mobility spectrometry (TIMS) mass spectrometer. A new nano-DESI source was constructed, and a specially designed inlet extension was fabricated to accommodate the new source. The nano-DESI-TIMS-MSI platform was evaluated by imaging mouse brain tissue sections. We achieved high ion mobility resolution by utilizing three narrow mobility scan windows that covered the majority of the lipid molecules. Notably, the mobility resolution reaching up to 300 in this study is much higher than the resolution obtained in our previous study using drift tube IMS. High-resolution TIMS successfully separated lipid isomers and isobars, revealing their distinct localizations in tissue samples. Our results further demonstrate the power of high-mobility-resolution IMS for unraveling the complexity of biomolecular mixtures analyzed in MSI experiments.