YKYasir Mohammed Kareem

Yasir Mohammed Kareem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yasir Mohammed Kareem has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the effect of barium titanate nanofiller addition on the thermal conductivity and physio-mechanical properties of maxillofacial silicone

    by Yasir M Kareem, Thekra I Hamad, Matheel Al-Rawas

    Background: Silicone elastomers have been extensively used as the most acceptable material in the manufacturing of maxillofacial and other kinds of prosthetic devices. The durability of maxillofacial prostheses depends on the material chosen, the patient's attitude and feelings regarding the prosthesis, and how they perform for specific needs. Aims: This study aimed to investigate the influence of adding barium titanate (BaTiO3) nanoparticles on the mechanical and physical characteristics of room-temperature-vulcanized (RTV) VerSilTal (VST-50) maxillofacial silicone elastomer, including thermal conductivity, tear strength, and water absorption and solubility. Materials and methods: 0.5 wt% and 0.75 wt% BaTiO3 nanoparticles were added to RTV VST-50 platinum silicone elastomer. Ninety specimens were prepared and divided into three main groups: one control group and two experimental groups (0.5 and 0.75 wt%). The collected data were statistically analyzed by one-way ANOVA and Tukey (HSD) test (significant level at P ≤ 0.05). The homogeneity and normal distribution of data were assessed by Levene's and Shapiro Wilk's tests, respectively. Result: Both experimental groups showed a remarkable increase in tear strength, thermal conductivity, and water absorption compared with the nonadditive control group. For solubility, the group of 0.5 wt% additive showed an insignificant increase, whereas the group of 0.75 wt% showed a significant increase compared with the control group. Conclusion: The addition of BaTiO3 nanoparticles to RTV VST-50 enhanced the thermal conductivity and tear strength. Water absorption and solubility were also increased, but the values were clinically insignificant. FTIR revealed no chemical interaction between BaTiO3 and silicone. FE-SEM showed the uniform scattering of BaTiO3 inside the silicone matrix.


  • Open Access

    Assessment of the antibacterial effect of Barium Titanate nanoparticles against Staphylococcus epidermidis adhesion after addition to maxillofacial silicone

    by Yasir Mohammed Kareem, Thekra Ismael Hamad

    Background: Maxillofacial silicones are the most popular and acceptable material for making maxillofacial prostheses, but they are not perfect in every sense. To enhance their effectiveness, more improvements to their properties are required, such as their antimicrobial efficiency. This study assess the antibacterial effect of barium titanate nanoparticles in various percentages against staphylococcus epidermidis biofilm adhesion after addition to maxillofacial silicone. Methods: Barium titanate nanoparticles were added into VST-50 platinum silicone elastomer in four weight percentages (0.25wt%, 0.5wt%, 0.75wt% and 1wt%). 50 specimens were prepared and categorized into five groups; one control group and four experimental groups. All conducted data was statistically analyzed using (one-way ANOVA) analysis of variance, and Games-Howell multiple comparison test (significant level at p < 0.05). Shapiro-Wilk and Levene’s tests were used, respectively, to evaluate the normal distribution and homogeneity of the data. Result: One-way ANOVA test revealed a highly significant difference between all groups, and Games-Howell test revealed a highly significant difference between the control group and the four experimental groups. The 0.25wt% and 0.5wt% groups revealed a highly significant difference between them and with the (0.75%wt and 0.1%wt) groups. While the 0.75wt% group revealed a significant difference with 1wt% group. Conclusions: The addition of barium titanate to VST-50 maxillofacial silicone enhanced the antibacterial activity of silicon against Staphylococcus epidermidis, and this activity seems to be concentration dependent. FTIR analysis demonstrated no chemical interaction between the Barium Titanate and the VST-50 maxillofacial silicone elastomer. SEM pictures show that the barium titanate nanopowder was effectively dispersed inside the maxillofacial silicone matrix.


  • Open Access

    Assessment of the antibacterial effect of Barium Titanate nanoparticles against Staphylococcus epidermidis adhesion after addition to maxillofacial silicone

    by Yasir Mohammed Kareem, Thekra Ismael Hamad

    Background: Maxillofacial silicones are the most popular and acceptable material for making maxillofacial prostheses, but they are not perfect in every sense. To enhance their effectiveness, more improvements to their properties are required, such as their antimicrobial efficiency. This study assess the antibacterial effect of barium titanate nanoparticles in various percentages against staphylococcus epidermidis biofilm adhesion after addition to maxillofacial silicone. Methods: Barium titanate nanoparticles were added into VST-50 platinum silicone elastomer in four weight percentages (0.25wt%, 0.5wt%, 0.75wt% and 1wt%). 50 specimens were prepared and categorized into five groups; one control group and four experimental groups. All conducted data was statistically analyzed using (one-way ANOVA) analysis of variance, and Games-Howell multiple comparison test (significant level at p < 0.05). Shapiro-Wilk and Levene’s tests were used, respectively, to evaluate the normal distribution and homogeneity of the data. Result: One-way ANOVA test revealed a highly significant difference between all groups, and Games-Howell test revealed a highly significant difference between the control group and the four experimental groups. The 0.25wt% and 0.5wt% groups revealed a highly significant difference between them and with the (0.75%wt and 0.1%wt) groups. While the 0.75wt% group revealed a significant difference with 1wt% group. Conclusions: The addition of barium titanate to VST-50 maxillofacial silicone enhanced the antibacterial activity of silicon against Staphylococcus epidermidis, and this activity seems to be concentration dependent. FTIR analysis demonstrated no chemical interaction between the Barium Titanate and the VST-50 maxillofacial silicone elastomer. SEM pictures show that the barium titanate nanopowder was effectively dispersed inside the maxillofacial silicone matrix.