CWChunbo Wang

Chunbo Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunbo Wang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Jiahui Yang

    State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China

    3 shared publications
  • Jie Zhao

    State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China

    3 shared publications
  • Yanhe Zhu

    State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China

    3 shared publications
  • Haoran Yi

    The School of Mechatronics Engineering Harbin Institute of Technology Harbin Heilongjiang 150001 China

    2 shared publications
  • He Zhang

    The School of Mechatronics Engineering Harbin Institute of Technology Harbin Heilongjiang 150001 China

    2 shared publications
  • He Zhang

    State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China

    2 shared publications

Latest Publications

  • Top Cited Papers
    Open Access

    Interaction-aware dexterous robot for minimally invasive transcanal inner ear interventions

    by Haiming Li, Peiyuan Gao, Haoyue Tan, Haotian Li, Haifeng Zhu, Mengyuan Jiang, Yuting Ni, Yandi He, Junhong Huang, Yue Zhu, et al.

    Intracochlear theranostics, particularly targeted drug delivery and microsampling, offers a promising solution to inner ear diseases. However, specialized medical devices remain limited by a fundamental design challenge imposed by anatomical constraints: balancing miniaturization, dexterity, and perceptive functionality. Here, we present a low–aspect-ratio, dual-segment continuum robot that integrates catheter, endoscopic and instrumental functions. Driven by antagonistic cables, the robot uses a transition-free backbone composed of saddle-shaped joints to achieve a minimum bending radius of 1.9 mm. Dual-segment motion decoupling yields programmable C-/S-shaped configurations, facilitating anatomical navigation. The microneedle, embedded in the central channel, serves as an end-effector with positioning accuracy of 17.9 ± 4.1 μm. Fiber Bragg grating sensors, mounted on the needle, measure axial force to estimate tool-tissue interaction. Validation is performed on cadavers and in vivo animals, demonstrating the feasibility of a transcanal, atraumatic robotic paradigm. Thus, this system provides a practical and accessible approach for early diagnosis and treatment, helping extend precision medicine to underserved areas.


  • A Robotic Microforceps for Retinal Microsurgery With Adaptive Clamping Method

    by He Zhang, Haoran Yi, Chunbo Wang, Jiahui Yang, Taixian Jin, Jie Zhao

    Epiretinal membrane peel surgery requires the surgeon to perform precise operation on delicate tissue within the narrow space of the eye, which is considered as one of the most technically demanding procedures. Using surgical robots to assist surgeons in performing operations is a recognized development direction. The automatic microforceps, as a device mounted at the end of the robotic arm and directly in contact with the affected area, has been the subject of research by many scholars. However, current research has significant shortcomings in both the calibration algorithms for the sensors and the control methods for the microforceps. In this article, we introduce an automated microforceps designed for epiretinal membrane peeling procedures. Despite its compact radial dimension of just 20 mm, the jaw of the microforceps possesses the following two degrees of freedom (DOF): 1) rotation and 2) closure. Subsequently, we analyzed the changes in the physical model of the 3-DOF force sensor after its integration into the microforceps, leading us to propose a refined calibration algorithm tailored for our designed automated microforceps. Furthermore, we introduced a force-based adaptive clamping method suitable for variety of unknown thickness films. Both polyethylene terephthalate (PET) film experiments and generalization experiments demonstrated the stability and generalizability of the adaptive clamping method.


  • Open Access

    A Micro‐3‐Degree‐of‐Freedom Force Sensor for Intraocular Dexterous Surgical Robots

    by He Zhang, Chunbo Wang, Ming Bai, Haoran Yi, Jiahui Yang, Yanhe Zhu, Jie Zhao


  • Open Access

    A Micro‐3‐Degree‐of‐Freedom Force Sensor for Intraocular Dexterous Surgical Robots

    by He Zhang, Chunbo Wang, Ming Bai, Haoran Yi, Jiahui Yang, Yanhe Zhu, Jie Zhao

    The continuum manipulator improves the intraocular robot flexibility during retinal surgery. Herein, a micro‐3‐degree of freedom (DOF) force sensor with a length of only 3.8 mm that can adjust the puncture angle during retinal vein cannulation (RVC) is proposed. Taking advantage of 3D printing technology, the optical fiber and injection line are embedded in the nitinol tube with flexible hinges to achieve integration of the force sensing and injection functions. A new fiber Bragg grating (FBG) configuration method and linear decoupling algorithm are also proposed herein. Static calibration experiments demonstrate excellent resolution of the force sensor, of less than 0.072 mN for transverse force and 0.738 mN for the axial force in the range from −20 to 20 mN. The proposed sensor is installed on a newly developed actuator, and an ex vivo experiment is performed on pig cadaver eyes. The interaction forces at each stage of the RVC are recorded in detail for the first time, further confirming the feasibility and effectiveness of the developed sensor for monitoring the RVC interaction forces.