Muhammad Auzan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Auzan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Andi Dharmawan
Universitas Gadjah Mada
3 shared publications - Bakhtiar Alldino Ardi Sumbodo
Universitas Gadjah Mada
3 shared publications - Jazi Eko Istiyanto
Universitas Gadjah Mada
3 shared publications - Oskar Natan
Universitas Gadjah Mada
3 shared publications Muhammad Arsyi
Universitas Gadjah Mada
2 shared publications- Yong-Lin Kuo
Graduate Institute of Automation and Control, the College of Engineering, National Taiwan University of Science and Techonology, Taipei, Taiwan
2 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (4)
Humanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (4)
Open AccessHumanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (4) , 320-330
Humanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (4) , 320-330
Open AccessHumanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 320-330
Humanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 320-330
Open AccessHumanoid robot balance control system during backward walking using linear quadratic regulator
Humanoid robots are designed to replicate human activities, including tasks in hazardous environments. However, maintaining balance during backward walking remains a significant challenge due to center of mass (CoM) shifts beyond the support polygon and limited knee joint motion. This study proposes a control strategy that integrates a linear quadratic regulator (LQR) with optimized walking patterns to enhance dynamic stability. The approach combines LQR-based control with CoM trajectory planning to ensure safe and stable backward walking. The methodology includes inverse kinematics for generating walking patterns and the use of Inertial Measurement Unit (IMU) sensors to estimate the CoM trajectory. LQR parameters were tuned through simulation to improve responsiveness to disturbances. Evaluation metrics focused on CoM deviation, rise time, settling time, and overshoot. Experimental results demonstrate that the proposed LQR system effectively maintains the CoM within 5% of the support polygon boundary. The system achieved rise times under one second and settling times below two seconds, while minimizing pitch and roll overshoots. Compared to proportional control, the proposed method significantly improves stability and reduces the risk of falling. This research advances control strategies for humanoid robots, contributing to improved mobility and operational safety. Moreover, it supports Sustainable Development Goal (SDG) 9 by promoting innovation in intelligent robotic systems that can assist in complex or high-risk environments.
- Open Access
- 16 June 2025
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 16 (9)
Barrier function-based adaptive synergetic control with state constraints for manipulator with uncertainty and input saturation
- 16 June 2025
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 16 (9)
Open AccessBarrier function-based adaptive synergetic control with state constraints for manipulator with uncertainty and input saturation
- Open Access
- 31 October 2023
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 17 (4) , 337-346
Classification Methods Performance On Logistic Package State Recognition
In the distribution sector, logistic package experience activities, such as transport, distribution, storage, packaging, and handling. Even though those processes have reasonable operational procedures, sometimes the package experience mishandling. The mishandling is hard to identify because many packages run simultaneously, and not all processes are monitored. An Inertial Measurement Unit (IMU) is installed inside a package to collect three acceleration and rotation data. The data is then labeled manually into four classes: correct handling, vertical fall, and thrown and rotating fall. Then, using cross-validation, ten classifiers were used to generate a model to classify the logistic package status and evaluate the accuracy score. It is hard to differentiate between free-fall and thrown. The classification only uses the accelerometer data to minimize the running time. The correct handling classification gives a good result because the data pattern has few variations. However, the thrown, free-fall and rotating data give a lower result because the pattern resembles each other. The average accuracy of the ten classifications is 78.15, with a mean deviation of 4.31. The best classifier for this research is the Gaussian Process, with a mean accuracy of 94.4 % and a deviation of 3.5 %.
- 31 October 2023
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 17 (4) , 337-346
Open AccessClassification Methods Performance On Logistic Package State Recognition
In the distribution sector, logistic package experience activities, such as transport, distribution, storage, packaging, and handling. Even though those processes have reasonable operational procedures, sometimes the package experience mishandling. The mishandling is hard to identify because many packages run simultaneously, and not all processes are monitored. An Inertial Measurement Unit (IMU) is installed inside a package to collect three acceleration and rotation data. The data is then labeled manually into four classes: correct handling, vertical fall, and thrown and rotating fall. Then, using cross-validation, ten classifiers were used to generate a model to classify the logistic package status and evaluate the accuracy score. It is hard to differentiate between free-fall and thrown. The classification only uses the accelerometer data to minimize the running time. The correct handling classification gives a good result because the data pattern has few variations. However, the thrown, free-fall and rotating data give a lower result because the pattern resembles each other. The average accuracy of the ten classifications is 78.15, with a mean deviation of 4.31. The best classifier for this research is the Gaussian Process, with a mean accuracy of 94.4 % and a deviation of 3.5 %.
- Open Access
- 31 July 2023
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 17 (3) , 249-258
Flower Pollination Inspired Algorithm on Exchange Rates Prediction Case
Flower pollination algorithm is a bio-inspired system that adapts a similar process to genetic algorithm, that aims for optimization problems. In this research, we examine the utilization of the flower pollination algorithm in linear regression for currency exchange cases. The solutions are represented as a set that contains regression coefficients. Population size for the candidate solutions and the switch probability between global pollination and local pollination have been experimented with in this research. Our result shows that the final solution is better when a higher size population and higher switch probability are employed. Furthermore, our result shows the higher size of the population leads to considerable running time, where the leaning probability of global pollination slightly increases the running time.
- 31 July 2023
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 17 (3) , 249-258
Open AccessFlower Pollination Inspired Algorithm on Exchange Rates Prediction Case
Flower pollination algorithm is a bio-inspired system that adapts a similar process to genetic algorithm, that aims for optimization problems. In this research, we examine the utilization of the flower pollination algorithm in linear regression for currency exchange cases. The solutions are represented as a set that contains regression coefficients. Population size for the candidate solutions and the switch probability between global pollination and local pollination have been experimented with in this research. Our result shows that the final solution is better when a higher size population and higher switch probability are employed. Furthermore, our result shows the higher size of the population leads to considerable running time, where the leaning probability of global pollination slightly increases the running time.
- Open Access
- 20 June 2023
- Published by Universitas Muhammadiyah Yogyakarta in Journal of Robotics and Control (JRC)
- Vol. 4 (4) , 548-556
Humanoid Walking Control Using LQR and ANFIS
Humanoid robots possess remarkable mobility and adaptability for diverse environments. Nonetheless, accurate walking pattern tracking remains challenging, especially when employing the linear quadratic regulator (LQR) due to delays in high-mobility setpoint tracking. We propose a novel control approach to address this limitation by integrating an artificial neuro-fuzzy inference system (ANFIS) with the LQR to enhance pattern tracking. The research contributes to developing a control system that combines LQR and ANFIS to enable humanoid robots to follow various walking patterns with increased precision and efficiency and also the scheme to incorporate LQR and ANFIS. The study involves four experiments: step response, walking phase, static straight walking, and varied straight walking. Each test runs for 5 seconds with a 100-millisecond sampling rate, repeated five times, and employs the Integral Absolute Value (IAE) metric for evaluation. The LQR-ANFIS method exhibits superior performance, achieving a maximum overshoot of 0%, a rise time of 0.3 seconds, a settling time of 0.3 seconds, and a steady-state error of 0% in the step response experiment. The proposed control system also enables stable walking with step periods ranging from 0.15 to 4 seconds and step ranges of 0.05 to 0.03 meters. In conclusion, the integration of ANFIS with the LQR significantly enhances the mobility of humanoid robots, enabling them to navigate diverse environments and accurately track various walking patterns proficiently.
- 20 June 2023
- Published by Universitas Muhammadiyah Yogyakarta in Journal of Robotics and Control (JRC)
- Vol. 4 (4) , 548-556
Open AccessHumanoid Walking Control Using LQR and ANFIS
Humanoid robots possess remarkable mobility and adaptability for diverse environments. Nonetheless, accurate walking pattern tracking remains challenging, especially when employing the linear quadratic regulator (LQR) due to delays in high-mobility setpoint tracking. We propose a novel control approach to address this limitation by integrating an artificial neuro-fuzzy inference system (ANFIS) with the LQR to enhance pattern tracking. The research contributes to developing a control system that combines LQR and ANFIS to enable humanoid robots to follow various walking patterns with increased precision and efficiency and also the scheme to incorporate LQR and ANFIS. The study involves four experiments: step response, walking phase, static straight walking, and varied straight walking. Each test runs for 5 seconds with a 100-millisecond sampling rate, repeated five times, and employs the Integral Absolute Value (IAE) metric for evaluation. The LQR-ANFIS method exhibits superior performance, achieving a maximum overshoot of 0%, a rise time of 0.3 seconds, a settling time of 0.3 seconds, and a steady-state error of 0% in the step response experiment. The proposed control system also enables stable walking with step periods ranging from 0.15 to 4 seconds and step ranges of 0.05 to 0.03 meters. In conclusion, the integration of ANFIS with the LQR significantly enhances the mobility of humanoid robots, enabling them to navigate diverse environments and accurately track various walking patterns proficiently.
- Open Access
- 31 July 2022
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 16 (3) , 261-270
Spectrogram Window Comparison: Cough Sound Recognition using Convolutional Neural Network
Cough is one of the most common symptoms of diseases, especially respiratory diseases. Quick cough detection can be the key to the current pandemic of COVID-19. Good cough recognition is the one that uses non-intrusive tools such as a mobile phone microphone that does not disable human activities like stick sensors. To do sound-only detection, Deep Learning current best method Convolutional Neural Network (CNN) is used. However, CNN needs image input while sound input differs (one dimension rather than two). An extra process is needed, converting sound data to image data using a spectrogram. When building a spectrogram, there is a question about the best size. This research will compare the spectrogram's size, called Spectrogram Window, by the performance. The result is that windows with 4 seconds have the highest F1-score performance at 92.9%. Therefore, a window of around 4 seconds will perform better for sound recognition problems.
- 31 July 2022
- Published by Universitas Gadjah Mada in IJCCS (Indonesian Journal of Computing and Cybernetics Systems)
- Vol. 16 (3) , 261-270
Open AccessSpectrogram Window Comparison: Cough Sound Recognition using Convolutional Neural Network
Cough is one of the most common symptoms of diseases, especially respiratory diseases. Quick cough detection can be the key to the current pandemic of COVID-19. Good cough recognition is the one that uses non-intrusive tools such as a mobile phone microphone that does not disable human activities like stick sensors. To do sound-only detection, Deep Learning current best method Convolutional Neural Network (CNN) is used. However, CNN needs image input while sound input differs (one dimension rather than two). An extra process is needed, converting sound data to image data using a spectrogram. When building a spectrogram, there is a question about the best size. This research will compare the spectrogram's size, called Spectrogram Window, by the performance. The result is that windows with 4 seconds have the highest F1-score performance at 92.9%. Therefore, a window of around 4 seconds will perform better for sound recognition problems.