H. Meyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. Meyer has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Seth Hussey
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
2 shared publications - I. Hidrovo
Department of Physics and Astronomy, Louisiana State University 1 , Baton Rouge, Louisiana 70803, USA
2 shared publications - Joyoni Dey
Department of Physics and Astronomy, Louisiana State University, Baton Rouge, USA
2 shared publications - Kyungmin Ham
Center for Advanced Microstructures and Devices, Louisiana State University 4 , Baton Rouge, Louisiana 70806, USA
2 shared publications - Leslie G. Butler
Louisiana State University 2 , Baton Rouge, Louisiana 70803
2 shared publications - Wayne D. Newhauser
Louisiana State University
2 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Erratum: “Neutron interferometry using a single modulated phase grating” [Rev. Sci. Instrum. 94, 045110 (2023)]
In our paper,1 we have a couple of corrections. In our paper,1 we have a couple of corrections.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Open AccessErratum: “Neutron interferometry using a single modulated phase grating” [Rev. Sci. Instrum. 94, 045110 (2023)]
In our paper,1 we have a couple of corrections. In our paper,1 we have a couple of corrections.
- Open Access
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Neutron interferometry using a single modulated phase grating
Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moiré interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moiré far-field technique to avoid the need for high-aspect absorption gratings used in Talbot–Lau interferometers (TLI) that reduce the neutron flux reaching the detector. We first demonstrate, through theory and simulations, a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. The theory shows the dual modulation of MPG with a large period and a smaller carrier pitch P, resulting in large fringes at the detector. The theory was compared to the full Sommerfeld–Rayleigh diffraction integral simulator. Then, we proceeded to compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39%. The simulations of the MPG system show improved visibility in comparison to that of the two-phase-grating-based PGMI. An MPG with a modulation period of 300 µm, the pitch of 2 µm, and grating heights with a phase modulation of (π,0, illuminated by a monochromatic beam produces visibility of 94.2% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer, was compared to values available in the literature, viz. the conventional TLI with the phase sensitivity of 4.5 × 103 for an SDD of 3.5 m and a beam wavelength of 0.44 nm. For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 × 103 to 10.0 × 103 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of two phase gratings.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Open AccessNeutron interferometry using a single modulated phase grating
Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moiré interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moiré far-field technique to avoid the need for high-aspect absorption gratings used in Talbot–Lau interferometers (TLI) that reduce the neutron flux reaching the detector. We first demonstrate, through theory and simulations, a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. The theory shows the dual modulation of MPG with a large period and a smaller carrier pitch P, resulting in large fringes at the detector. The theory was compared to the full Sommerfeld–Rayleigh diffraction integral simulator. Then, we proceeded to compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39%. The simulations of the MPG system show improved visibility in comparison to that of the two-phase-grating-based PGMI. An MPG with a modulation period of 300 µm, the pitch of 2 µm, and grating heights with a phase modulation of (π,0, illuminated by a monochromatic beam produces visibility of 94.2% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer, was compared to values available in the literature, viz. the conventional TLI with the phase sensitivity of 4.5 × 103 for an SDD of 3.5 m and a beam wavelength of 0.44 nm. For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 × 103 to 10.0 × 103 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of two phase gratings.