Camilo Gustavo Araújo Alves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Camilo Gustavo Araújo Alves has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
André Maurente
Department of Mechanical Engineering, Federal University of Rio Grande do Norte, Campus Universitário, Lagoa Nova, Natal, RN 59072-970, Brazil
1 shared publication- Francisco Bernardino da Silva Neto
Lauro Wanderley University Hospital, Federal University of Paraiba (UFPB), João Pessoa 58051-900, Brazil
1 shared publication - Gustavo Charles Peixoto de Oliveira
TRIL Lab, Federal University of Paraíba, João Pessoa, Brazil
1 shared publication - Gustavo R. Anjos
Department of Mechanical Engineering—COPPE, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-914, Brazil
1 shared publication - José Tadeu C. Junior
Mechanical Engineering Department, FEI University Center, São Bernardo do Campo 09850-901, Brazil
1 shared publication - Moisés Dantas dos Santos
TRIL Lab, Federal University of Paraíba, João Pessoa, Brazil
1 shared publication
Latest Publications
- Open Access
Indoor Airflow Dynamics in Compartmentalized Pneumology Units Equipped with Variable-Thickness MERV-13 Filters
Infection containment in the post-pandemic scenario became a top priority for healthcare engineering control staffers, especially in pneumology sectors, where the treatment of airborne infectious diseases is frequent. In Brazil, where COVID-19 left a long record of casualties, there is a lack of information on the influence of filtration systems on the maintenance of regulated operational conditions for indoor comfort in hospital environments. This paper has the following objectives: to study arrangements of filtering systems in hospital acclimatization ducts; to verify how filtering characteristics could compromise safety regulations for airflow in hospital environments; and to identify airflow stagnation points that might favor suspended viral concentrations and increase contamination risks. We used the computational fluid dynamics STAR-CCM+© software to perform numerical simulations of different cases of indoor airflow in a model corresponding to a sector of the Lauro Wanderley University Hospital (João Pessoa city, Brazil). We concluded that standards for maximum velocity are reachable despite thinner or thicker filters affecting the spread of the air. In this way, acclimatization systems are limited by a tradeoff between regulation and protection. Our findings are relevant to future technological development, interventions, safety strategies amidst contamination scenarios, and new filtration arrangements in hospital environments.
Open AccessIndoor Airflow Dynamics in Compartmentalized Pneumology Units Equipped with Variable-Thickness MERV-13 Filters
Infection containment in the post-pandemic scenario became a top priority for healthcare engineering control staffers, especially in pneumology sectors, where the treatment of airborne infectious diseases is frequent. In Brazil, where COVID-19 left a long record of casualties, there is a lack of information on the influence of filtration systems on the maintenance of regulated operational conditions for indoor comfort in hospital environments. This paper has the following objectives: to study arrangements of filtering systems in hospital acclimatization ducts; to verify how filtering characteristics could compromise safety regulations for airflow in hospital environments; and to identify airflow stagnation points that might favor suspended viral concentrations and increase contamination risks. We used the computational fluid dynamics STAR-CCM+© software to perform numerical simulations of different cases of indoor airflow in a model corresponding to a sector of the Lauro Wanderley University Hospital (João Pessoa city, Brazil). We concluded that standards for maximum velocity are reachable despite thinner or thicker filters affecting the spread of the air. In this way, acclimatization systems are limited by a tradeoff between regulation and protection. Our findings are relevant to future technological development, interventions, safety strategies amidst contamination scenarios, and new filtration arrangements in hospital environments.
- 1 December 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 145, 118734
Radiation heat transfer in a gas slab with properties characteristics of a jet engine combustor
- 1 December 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 145, 118734
Radiation heat transfer in a gas slab with properties characteristics of a jet engine combustor