Martin Srb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Srb has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Anna Cardova
Department of Water Technology and Environmental Engineering, Faculty of Environmental Technology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague, Czech Republic
2 shared publications - Lise Appels
KU Leuven
2 shared publications - Pavel Jenicek
University of Chemistry and Technology, Prague
2 shared publications - Vojtěch Kouba
Department of Water Technology and Environmental Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague, Czechia
2 shared publications - Christina Karmann
Department of Water Technology and Environmental Engineering University of Chemistry and Technology Prague Prague Czechia
1 shared publication - Dana Kok
Department of Water Technology and Environmental Engineering, University of Chemistry and Technology Prague, Czechia
1 shared publication
Latest Publications
- 28 May 2026
- Published by IWA Publishing in Water Practice & Technology
Automation of aeration control based on nitrogen parameters at the New Water Line of the Central Wastewater Treatment Plant in Prague
Schematic comparison of aeration control strategies at the Prague Central Wastewater Treatment Plant. The abstract is divided into three panels. LEFT PANEL: Conventional control uses a fixed O₂ setpoint and fixed aeration cycles, resulting in NOx accumulation. MIDDLE PANEL: Smart automated control adjusts the O₂ setpoint dynamically based on ratio N-NOx/N-NH4 and threshold concentrations of N-NH₄ and N-NOx, with minimum and maximum aeration times and O₂ limits. RIGHT PANEL: This approach maintains stable ammonium levels, reduces NOx accumulation, and increases nitrogen removal efficiency from 82% to 86%. This paper describes the implementation of automated aeration control at the New Water Line (NWL) of the Central Wastewater Treatment Plant in Prague. The system utilizes a dynamic oxygen setpoint based on N-NH4 concentration and intermittent aeration regulated by the N-NOx/N-NH4 ratio, with defined boundary conditions. The results indicate that the new control method led to an increase in total nitrogen (Ntot) removal efficiency in the biological stage in 2025. The improved Ntot removal efficiency achieved using automatic control, compared to the original aeration control method, was confirmed by both long-term monitoring and targeted operational tests.
- 28 May 2026
- Published by IWA Publishing in Water Practice & Technology
Automation of aeration control based on nitrogen parameters at the New Water Line of the Central Wastewater Treatment Plant in Prague
Schematic comparison of aeration control strategies at the Prague Central Wastewater Treatment Plant. The abstract is divided into three panels. LEFT PANEL: Conventional control uses a fixed O₂ setpoint and fixed aeration cycles, resulting in NOx accumulation. MIDDLE PANEL: Smart automated control adjusts the O₂ setpoint dynamically based on ratio N-NOx/N-NH4 and threshold concentrations of N-NH₄ and N-NOx, with minimum and maximum aeration times and O₂ limits. RIGHT PANEL: This approach maintains stable ammonium levels, reduces NOx accumulation, and increases nitrogen removal efficiency from 82% to 86%. This paper describes the implementation of automated aeration control at the New Water Line (NWL) of the Central Wastewater Treatment Plant in Prague. The system utilizes a dynamic oxygen setpoint based on N-NH4 concentration and intermittent aeration regulated by the N-NOx/N-NH4 ratio, with defined boundary conditions. The results indicate that the new control method led to an increase in total nitrogen (Ntot) removal efficiency in the biological stage in 2025. The improved Ntot removal efficiency achieved using automatic control, compared to the original aeration control method, was confirmed by both long-term monitoring and targeted operational tests.
- Open Access
- 11 December 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 12 (2) , 563-576
Thermal hydrolysis on the edge of thermophilic anaerobic digestion: a pilot-scale operation experience
This study investigated the integration of the thermal hydrolysis process (THP) as a pretreatment with thermophilic anaerobic digestion (TAD) at a pilot scale using sludge from a full-scale wastewater treatment plant. This is the first pilot-scale evaluation of THP–TAD employing thermophilic inoculum adapted to hydrolysed sludge, offering critical insights into the potential of THP (155 °C, 30 minutes) to enhance TAD (55 °C) performance and contribute to sustainable sludge management. This study assessed the effects of THP on process stability at reduced hydraulic retention times (HRTs), biogas production, sludge dewaterability, and antibiotic resistance gene (ARG) reduction. The THP achieved a sludge disintegration degree of 26.8%, enabling a 50% reduction in HRT without compromising the reactor stability or process efficiency. At an HRT of 12 days, the specific biogas production averaged 0.28 Nm3 kg−1 VSin. Additionally, compared with traditional processes with longer HRTs, THP significantly enhanced ARG reduction, achieving a maximum reduction of 3.5 log units, while improving sludge hygienization and maintaining volatile solids reduction (VSR). Despite performance improvements, THP–TAD requires higher energy input, underscoring the need for optimization strategies. This study demonstrated that THP–TAD is a robust and effective approach for intensifying anaerobic digestion, offering notable reductions in capital costs (digester volume) while addressing critical environmental challenges such as ARG mitigation. Further investigations into sludge thickening and energy efficiency optimization are necessary to fully realize the potential of this technology as a cornerstone of sustainable wastewater management.
- 11 December 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 12 (2) , 563-576
Open AccessThermal hydrolysis on the edge of thermophilic anaerobic digestion: a pilot-scale operation experience
This study investigated the integration of the thermal hydrolysis process (THP) as a pretreatment with thermophilic anaerobic digestion (TAD) at a pilot scale using sludge from a full-scale wastewater treatment plant. This is the first pilot-scale evaluation of THP–TAD employing thermophilic inoculum adapted to hydrolysed sludge, offering critical insights into the potential of THP (155 °C, 30 minutes) to enhance TAD (55 °C) performance and contribute to sustainable sludge management. This study assessed the effects of THP on process stability at reduced hydraulic retention times (HRTs), biogas production, sludge dewaterability, and antibiotic resistance gene (ARG) reduction. The THP achieved a sludge disintegration degree of 26.8%, enabling a 50% reduction in HRT without compromising the reactor stability or process efficiency. At an HRT of 12 days, the specific biogas production averaged 0.28 Nm3 kg−1 VSin. Additionally, compared with traditional processes with longer HRTs, THP significantly enhanced ARG reduction, achieving a maximum reduction of 3.5 log units, while improving sludge hygienization and maintaining volatile solids reduction (VSR). Despite performance improvements, THP–TAD requires higher energy input, underscoring the need for optimization strategies. This study demonstrated that THP–TAD is a robust and effective approach for intensifying anaerobic digestion, offering notable reductions in capital costs (digester volume) while addressing critical environmental challenges such as ARG mitigation. Further investigations into sludge thickening and energy efficiency optimization are necessary to fully realize the potential of this technology as a cornerstone of sustainable wastewater management.
- Open Access
- 4 September 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 92 (6) , 843-855
Intensification of thermophilic anaerobic digestion of sewage sludge by thermal hydrolysis
Thermal hydrolysis (THP) combined with thermophilic anaerobic digestion (TAD) offers promising pathways for enhancing sewage sludge treatment. This study is among the first to directly compare THP as both pre- and post-treatment options for TAD. Pre-treatment of waste activated sludge (THP-WAS) and post-treatment of digested sludge (THP-DS) were evaluated on their impacts on process stability, biogas production, and sludge dewaterability. Pilot-scale trials at a wastewater treatment plant (WWTP) in Prague revealed that THP-WAS increased sludge solubilization but faced challenges such as volatile fatty acid accumulation, adversely affecting reactor stability and specific biogas yield. In contrast, THP-DS enhanced biogas production by 10%, improved sludge dewaterability, and achieved superior methane content (73.2%). Further research is needed to optimize THP parameters for reactor stability and to better understand interactions between hydrolyzed WAS and primary sludge.
- 4 September 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 92 (6) , 843-855
Open AccessIntensification of thermophilic anaerobic digestion of sewage sludge by thermal hydrolysis
Thermal hydrolysis (THP) combined with thermophilic anaerobic digestion (TAD) offers promising pathways for enhancing sewage sludge treatment. This study is among the first to directly compare THP as both pre- and post-treatment options for TAD. Pre-treatment of waste activated sludge (THP-WAS) and post-treatment of digested sludge (THP-DS) were evaluated on their impacts on process stability, biogas production, and sludge dewaterability. Pilot-scale trials at a wastewater treatment plant (WWTP) in Prague revealed that THP-WAS increased sludge solubilization but faced challenges such as volatile fatty acid accumulation, adversely affecting reactor stability and specific biogas yield. In contrast, THP-DS enhanced biogas production by 10%, improved sludge dewaterability, and achieved superior methane content (73.2%). Further research is needed to optimize THP parameters for reactor stability and to better understand interactions between hydrolyzed WAS and primary sludge.
- Open Access
- 26 April 2023
- Published by Elsevier in Journal of Environmental Management
- Vol. 340, 117861
Synergistic removal of pharmaceuticals and antibiotic resistance from ultrafiltered WWTP effluent: Free-floating ARGs exceptionally susceptible to degradation
- 26 April 2023
- Published by Elsevier in Journal of Environmental Management
- Vol. 340, 117861
Open AccessSynergistic removal of pharmaceuticals and antibiotic resistance from ultrafiltered WWTP effluent: Free-floating ARGs exceptionally susceptible to degradation
- Open Access
- 18 April 2023
- Published by IWA Publishing in Water Supply
- Vol. 23 (5) , 1859-1873
Prague Water Net Zero Strategy 2025: methodology and roadmap
In 2019, Prague set out its Prague 2030 Climate Plan and Pražské vodovody a kanalizace, a.s., as the operator of drinking water supply and drainage facility in Prague and Pražská vodohospodářská společnost, a.s., responsible for infrastructure management (collectively known as Prague Water) are a natural part of the mitigation and adaptation activities. Both companies committed to reaching a net zero operational CO2 footprint in 2035. The carbon footprint of the company will be certified according to the ČSN ISO 14064-1 standard. The paper presents a roadmap of the early stage of the project, the calculation of the CO2 footprint and the ISO certification process together with planned mitigation activities. The main goal of the contribution is to share know-how about the application of carbon-wise management principles in a large utility company. This makes the paper useful for worldwide utilities at a similar stage of carbon footprint measurement and reduction.
- 18 April 2023
- Published by IWA Publishing in Water Supply
- Vol. 23 (5) , 1859-1873
Open AccessPrague Water Net Zero Strategy 2025: methodology and roadmap
In 2019, Prague set out its Prague 2030 Climate Plan and Pražské vodovody a kanalizace, a.s., as the operator of drinking water supply and drainage facility in Prague and Pražská vodohospodářská společnost, a.s., responsible for infrastructure management (collectively known as Prague Water) are a natural part of the mitigation and adaptation activities. Both companies committed to reaching a net zero operational CO2 footprint in 2035. The carbon footprint of the company will be certified according to the ČSN ISO 14064-1 standard. The paper presents a roadmap of the early stage of the project, the calculation of the CO2 footprint and the ISO certification process together with planned mitigation activities. The main goal of the contribution is to share know-how about the application of carbon-wise management principles in a large utility company. This makes the paper useful for worldwide utilities at a similar stage of carbon footprint measurement and reduction.
- Open Access
- 7 December 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (2) , 293-301
Commissioning of the new water line of the Central wastewater treatment plant in Prague and its impact on the operation of the existing water line
This paper describes the commissioning of the New Water Line (NWL) of the Central wastewater treatment plant in Prague and also the gradual reduction of the Existing Water Line (EWL) loading. Concerning the NWL, the gradual start-up of the process without inoculation will be described. As to the EWL, the presentation describes the adaptation of the EWL operation to the relatively quick reduction of loading to approximately. 35%.
- 7 December 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (2) , 293-301
Open AccessCommissioning of the new water line of the Central wastewater treatment plant in Prague and its impact on the operation of the existing water line
This paper describes the commissioning of the New Water Line (NWL) of the Central wastewater treatment plant in Prague and also the gradual reduction of the Existing Water Line (EWL) loading. Concerning the NWL, the gradual start-up of the process without inoculation will be described. As to the EWL, the presentation describes the adaptation of the EWL operation to the relatively quick reduction of loading to approximately. 35%.