KFKe Feng

Ke Feng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ke Feng has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An adaptive harmonic AFM probe with enhanced sensitivity for cellular imaging

    by Ke Feng, Lei Yuan, Xianmin Zhang

    Accurate classification of cellular images plays an indispensable role in early cancer diagnosis. Based on signal enhancement, harmonic atomic force microscopy (AFM), distinguished by its high resolution, demonstrates unique advantages in rapid acquisition and analysis of cellular images. Traditional harmonic probes are generally designed without sufficient consideration of environmental and sample-induced interference on probe vibration. However, in cellular imaging, environmental perturbations and heterogeneous mechanical properties of samples can significantly compromise imaging quality. To address the challenge of precision imaging in multi-environment cellular studies, we have developed an adaptive harmonic atomic force microscopy (A-HAFM) probe capable of generating stable harmonic signals in both atmospheric and liquid environments, enabling high-resolution cellular imaging and precise cell classification. Experimental studies involving 3600 samples of human cervical epithelial cells and human cervical cancer cells with varying invasiveness (HeLa and SiHa) demonstrated that the A-HAFM probe achieved 52.17% improvement in amplitude response sensitivity compared to conventional AFM, along with 60% enhancement in imaging clarity, with classification accuracy for normal vs cancer cells improved by 7.97% and between cancer subtypes (HeLa/SiHa) increased by 12.73%. By precisely characterizing cellular substructures and identifying physiological signatures, this technology establishes a promising platform for cellular-level diagnosis and therapeutic evaluation of cardiovascular diseases, malignant tumors, and other critical illnesses.

  • Impact of Dynamic Tip-Surface Interactions on Microdroplet Formation via Fluid Force Microscopy

    by Zhuobo Yang, Xianmin Zhang, Hai Li, Benliang Zhu, Ke Feng, Rixin Wang

    The emergence of FluidFM technology has presented a novel opportunity for selective aspiration and distribution of liquids at the sub-micron scale. However, precise control over droplet generation volume remains a challenging issue. This study investigates the impact of dynamic parameters between the tip and surface on droplet formation. Initially, we establish a finite element model to simulate the process from the formation of a liquid bridge between the hollow cantilever probe and the substrate to the rupture resulting in droplet formation. Additionally, we propose an image-based method for quantifying droplet volume. Subsequently, we construct a comprehensive experimental framework to delve into the influence of these parameters on microdroplet formation by monitoring the dynamic interaction parameters between the probe tip and the liquid surface. Finally, we optimize the parameters during the droplet generation process, enabling the formation of uniform arrays of microdroplets under controlled experimental conditions. Our study provides a reference for automation parameters of serial experiments and improves experimental throughput.


  • A Novel Harmonic Atomic Force Microscopy With Tip-Sample Couplings

    by Ke Feng, Jianhao Lai, Jiarui Gao, Chaoyu Cui, Benliang Zhu, Xianmin Zhang

    This article presents a novel harmonic atomic force microscopy with tip-sample couplings (TS-HAFM) working in force modulation mode for imaging samples of different mechanical properties. Compared with traditional harmonic atomic force microscopy (T-HAFM), TS-HAFM has better harmonic characteristics and imaging resolution. T-HAFM does not consider the effect of tip-sample couplings on probe vibration; it can only generate harmonics in the free vibration state. However, after the tip touches the sample, the tip-sample coupling shifts the probe frequency and attenuates the probe's harmonic characteristics. TS-HAFM considers the effect of tip-sample couplings on probe vibration and can prevent problems of image resolution reduction and vibration stability degradation caused by harmonic attenuation. We first tested the Young's modulus of the sample and calculated the tip-sample contact's equivalent contact stiffness based on the Johnson–Kendall–Roberts model. The harmonic probe with tip-sample couplings and the traditional harmonic probe were subsequently designed. Then, the two probes were applied to the topography detection of polypropylene spheres covered with PDMS film and cells on PDMS substrates. Experimental results showed that TS-HAFM was up to 2.01 times more sensitive than T-HAFM in detecting samples of different mechanical properties. When detecting soft samples on PDMS substrates, TS-HAFM still has higher imaging clarity. TS-HAFM has emerged as a powerful platform for high resolution imaging of samples with different mechanical properties, while improving resistance to system interference.


  • A novel analysis method for magnetically actuated soft origami mechanisms

    by Chaoyu Cui, Xianmin Zhang, Benliang Zhu, Hai Li, Hongchuan Zhang, Rixin Wang, Jianhao Lai, Ke Feng