Ke Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ke Feng has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Xianmin Zhang
South China University of Technology
3 shared publications - Benliang Zhu
South China University of Technology
2 shared publications - Hai Li
South China University of Technology
2 shared publications - Rixin Wang
South China University of Technology
2 shared publications Benliang Zhu
1 shared publicationChaoyu Cui
1 shared publication
Latest Publications
- 21 July 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (3)
An adaptive harmonic AFM probe with enhanced sensitivity for cellular imaging
Accurate classification of cellular images plays an indispensable role in early cancer diagnosis. Based on signal enhancement, harmonic atomic force microscopy (AFM), distinguished by its high resolution, demonstrates unique advantages in rapid acquisition and analysis of cellular images. Traditional harmonic probes are generally designed without sufficient consideration of environmental and sample-induced interference on probe vibration. However, in cellular imaging, environmental perturbations and heterogeneous mechanical properties of samples can significantly compromise imaging quality. To address the challenge of precision imaging in multi-environment cellular studies, we have developed an adaptive harmonic atomic force microscopy (A-HAFM) probe capable of generating stable harmonic signals in both atmospheric and liquid environments, enabling high-resolution cellular imaging and precise cell classification. Experimental studies involving 3600 samples of human cervical epithelial cells and human cervical cancer cells with varying invasiveness (HeLa and SiHa) demonstrated that the A-HAFM probe achieved 52.17% improvement in amplitude response sensitivity compared to conventional AFM, along with 60% enhancement in imaging clarity, with classification accuracy for normal vs cancer cells improved by 7.97% and between cancer subtypes (HeLa/SiHa) increased by 12.73%. By precisely characterizing cellular substructures and identifying physiological signatures, this technology establishes a promising platform for cellular-level diagnosis and therapeutic evaluation of cardiovascular diseases, malignant tumors, and other critical illnesses.
- 21 July 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (3)
An adaptive harmonic AFM probe with enhanced sensitivity for cellular imaging
Accurate classification of cellular images plays an indispensable role in early cancer diagnosis. Based on signal enhancement, harmonic atomic force microscopy (AFM), distinguished by its high resolution, demonstrates unique advantages in rapid acquisition and analysis of cellular images. Traditional harmonic probes are generally designed without sufficient consideration of environmental and sample-induced interference on probe vibration. However, in cellular imaging, environmental perturbations and heterogeneous mechanical properties of samples can significantly compromise imaging quality. To address the challenge of precision imaging in multi-environment cellular studies, we have developed an adaptive harmonic atomic force microscopy (A-HAFM) probe capable of generating stable harmonic signals in both atmospheric and liquid environments, enabling high-resolution cellular imaging and precise cell classification. Experimental studies involving 3600 samples of human cervical epithelial cells and human cervical cancer cells with varying invasiveness (HeLa and SiHa) demonstrated that the A-HAFM probe achieved 52.17% improvement in amplitude response sensitivity compared to conventional AFM, along with 60% enhancement in imaging clarity, with classification accuracy for normal vs cancer cells improved by 7.97% and between cancer subtypes (HeLa/SiHa) increased by 12.73%. By precisely characterizing cellular substructures and identifying physiological signatures, this technology establishes a promising platform for cellular-level diagnosis and therapeutic evaluation of cardiovascular diseases, malignant tumors, and other critical illnesses.
- 26 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 23 (1536125X) , 78-88
Impact of Dynamic Tip-Surface Interactions on Microdroplet Formation via Fluid Force Microscopy
The emergence of FluidFM technology has presented a novel opportunity for selective aspiration and distribution of liquids at the sub-micron scale. However, precise control over droplet generation volume remains a challenging issue. This study investigates the impact of dynamic parameters between the tip and surface on droplet formation. Initially, we establish a finite element model to simulate the process from the formation of a liquid bridge between the hollow cantilever probe and the substrate to the rupture resulting in droplet formation. Additionally, we propose an image-based method for quantifying droplet volume. Subsequently, we construct a comprehensive experimental framework to delve into the influence of these parameters on microdroplet formation by monitoring the dynamic interaction parameters between the probe tip and the liquid surface. Finally, we optimize the parameters during the droplet generation process, enabling the formation of uniform arrays of microdroplets under controlled experimental conditions. Our study provides a reference for automation parameters of serial experiments and improves experimental throughput.
- 26 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 23 (1536125X) , 78-88
Impact of Dynamic Tip-Surface Interactions on Microdroplet Formation via Fluid Force Microscopy
The emergence of FluidFM technology has presented a novel opportunity for selective aspiration and distribution of liquids at the sub-micron scale. However, precise control over droplet generation volume remains a challenging issue. This study investigates the impact of dynamic parameters between the tip and surface on droplet formation. Initially, we establish a finite element model to simulate the process from the formation of a liquid bridge between the hollow cantilever probe and the substrate to the rupture resulting in droplet formation. Additionally, we propose an image-based method for quantifying droplet volume. Subsequently, we construct a comprehensive experimental framework to delve into the influence of these parameters on microdroplet formation by monitoring the dynamic interaction parameters between the probe tip and the liquid surface. Finally, we optimize the parameters during the droplet generation process, enabling the formation of uniform arrays of microdroplets under controlled experimental conditions. Our study provides a reference for automation parameters of serial experiments and improves experimental throughput.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (3) , 2220-2229
A Novel Harmonic Atomic Force Microscopy With Tip-Sample Couplings
This article presents a novel harmonic atomic force microscopy with tip-sample couplings (TS-HAFM) working in force modulation mode for imaging samples of different mechanical properties. Compared with traditional harmonic atomic force microscopy (T-HAFM), TS-HAFM has better harmonic characteristics and imaging resolution. T-HAFM does not consider the effect of tip-sample couplings on probe vibration; it can only generate harmonics in the free vibration state. However, after the tip touches the sample, the tip-sample coupling shifts the probe frequency and attenuates the probe's harmonic characteristics. TS-HAFM considers the effect of tip-sample couplings on probe vibration and can prevent problems of image resolution reduction and vibration stability degradation caused by harmonic attenuation. We first tested the Young's modulus of the sample and calculated the tip-sample contact's equivalent contact stiffness based on the Johnson–Kendall–Roberts model. The harmonic probe with tip-sample couplings and the traditional harmonic probe were subsequently designed. Then, the two probes were applied to the topography detection of polypropylene spheres covered with PDMS film and cells on PDMS substrates. Experimental results showed that TS-HAFM was up to 2.01 times more sensitive than T-HAFM in detecting samples of different mechanical properties. When detecting soft samples on PDMS substrates, TS-HAFM still has higher imaging clarity. TS-HAFM has emerged as a powerful platform for high resolution imaging of samples with different mechanical properties, while improving resistance to system interference.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (3) , 2220-2229
A Novel Harmonic Atomic Force Microscopy With Tip-Sample Couplings
This article presents a novel harmonic atomic force microscopy with tip-sample couplings (TS-HAFM) working in force modulation mode for imaging samples of different mechanical properties. Compared with traditional harmonic atomic force microscopy (T-HAFM), TS-HAFM has better harmonic characteristics and imaging resolution. T-HAFM does not consider the effect of tip-sample couplings on probe vibration; it can only generate harmonics in the free vibration state. However, after the tip touches the sample, the tip-sample coupling shifts the probe frequency and attenuates the probe's harmonic characteristics. TS-HAFM considers the effect of tip-sample couplings on probe vibration and can prevent problems of image resolution reduction and vibration stability degradation caused by harmonic attenuation. We first tested the Young's modulus of the sample and calculated the tip-sample contact's equivalent contact stiffness based on the Johnson–Kendall–Roberts model. The harmonic probe with tip-sample couplings and the traditional harmonic probe were subsequently designed. Then, the two probes were applied to the topography detection of polypropylene spheres covered with PDMS film and cells on PDMS substrates. Experimental results showed that TS-HAFM was up to 2.01 times more sensitive than T-HAFM in detecting samples of different mechanical properties. When detecting soft samples on PDMS substrates, TS-HAFM still has higher imaging clarity. TS-HAFM has emerged as a powerful platform for high resolution imaging of samples with different mechanical properties, while improving resistance to system interference.
- 17 April 2023
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 186
A novel analysis method for magnetically actuated soft origami mechanisms
- 17 April 2023
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 186