YZYibo Zhou

Yibo Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yibo Zhou has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Power System Zoning and Regional Minimum Inertia Requirement Assessment Based on an Improved Spectral Clustering Approach

    by Meng Zhu, Yang Liu, Di An, Xin Hui, Kexin Li, Mo Zhou, Yibo Zhou, Xiaotian Zhang, Chuanliang Cao, Ziyun Wang

    With the large-scale integration of renewable-energy generating units, power-system inertia continues to decline and becomes unevenly distributed in space. Consequently, frequency responses differ markedly among regions following a disturbance, and assessment based on a single center-of-inertia (COI) frequency may conceal local frequency-security risks. This paper proposes a regional inertia assessment and minimum-inertia calculation method based on linearized analysis. First, a generalized relative correlation gain matrix is constructed from a linearized multi-machine model to quantify the dynamic correlation of generator frequency responses. Spectral clustering and the Calinski–Harabasz (CH) index are then used to determine the system partition. Next, synchronous-machine inertia, load-voltage characteristics, virtual inertia, and primary frequency control are considered in stages. The minimum regional inertia requirements are calculated under rate-of-change-of-frequency (RoCoF) and frequency-nadir constraints, and the larger value is taken as the regional inertia threshold. Simulations on the IEEE 10-machine 39-bus system show that the proposed partitions capture regional differences in frequency response and that the estimated values agree closely with the actual aggregated inertia after synchronous machines are replaced. When inertia is configured according to the calculated thresholds, the RoCoF and frequency nadir in every region satisfy the security constraints. Further analysis shows that the minimum inertia requirements under both constraints increase with disturbance magnitude. At a stringent RoCoF limit, the requirement is dominated by the RoCoF constraint; as the limit is relaxed, the frequency-nadir constraint progressively becomes dominant. The proposed method provides a reference for regional inertia assessment and frequency-security control in power systems with high renewable penetration.

  • Open Access

    Static Synchronous Stability Analysis of Synchronous Condensers Based on the Simplified Heffron–Phillips Model

    by Yong Meng, Yuanfei Lin, Xingwei Xu, Yugang Bao, Yibo Zhou

    To address insufficient dynamic reactive power support during large-scale new energy grid connection, synchronous condensers are widely used in centralized new energy delivery. As a special rotating electrical machine, their operational stability is critical to new energy power stations’ safe operation. Targeting practical application scenarios (synchronous condenser power delivery and new energy grid-connected systems with synchronous condensers), this paper establishes a simplified Heffron–Phillips model for their static stability analysis by integrating their actual operating characteristics into the traditional model. Specific electromagnetic torque component expressions are derived to reflect static stability. Mechanistically, it reveals the correlation between excitation system gain and torque, their impact on static synchronous stability, and obtains critical gain parameters for positive damping. Influencing factors are determined, and essential differences in additional torque characteristics between synchronous condensers and generators are clarified. Simulation models of the two systems verify the conclusions, providing theoretical support for engineering applications and a reference for practical parameter setting.


  • Open Access

    A Photovoltaic Power Prediction Method Based on Wavelet Convolutional Neural Networks and Improved Transformer

    by Yibo Zhou, Zihang Liu, Zhen Cheng, Hanglin Mi, Zhaoyang Qin, Kangyangyong Cao

    The output power of photovoltaic (PV) systems is influenced by various environmental factors, exhibiting strong nonlinearity and non-stationarity, which poses significant challenges for accurate forecasting. To address these issues, this paper proposes a short-term PV power forecasting method based on wavelet convolutional neural networks and an improved Transformer. First, the Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) is employed to decompose the original PV power sequence into several intrinsic mode functions (IMFs). Fuzzy entropy is then utilized to evaluate the complexity of each component, and subsequences with similar entropy values are reconstructed to reduce the non-stationarity of the original series. Subsequently, Pearson correlation coefficients and the maximal information coefficient (MIC) are applied to capture both linear and nonlinear relationships between each reconstructed component and meteorological features, enabling the selection of strongly correlated variables. On this basis, a wavelet convolutional network (WTConv) is introduced to perform multi-scale decomposition and frequency-band feature extraction on the reconstructed components by integrating wavelet transform with convolution operations, effectively expanding the receptive field and extracting deep-seated features of the sequences. Finally, an improved iTransformer model is adopted for time-series modeling, leveraging its inverted encoding structure and self-attention mechanism to fully capture long-term dependencies among multivariate variables. The proposed model is validated using actual power data from a PV plant in Ningxia, China, across four seasons. Comprehensive experiments, including ablation studies, comparative analyses, loss function convergence evaluation, and Diebold–Mariano significance tests, are conducted to thoroughly assess the model’s effectiveness and superiority. Experimental results demonstrate that the proposed model achieves excellent prediction accuracy and stability in spring, summer, autumn, and winter, showing strong potential for engineering applications.


  • Open Access

    A Method for Identification and Adjustment of Key Variables for Power Flow Convergence in Bulk Power Systems Based on Unbalanced Power Characteristics of Intermediate Power Flow

    by Yuxi Fan, Yibo Zhou

    In the operation mode arrangement of bulk power systems, unreasonable reactive power injection data at nodes tend to result in power flow calculation non-convergence. Owing to the extremely high dimension of the variable space and the heterogeneous impacts of different variables on power flow convergence, it is imperative to accurately identify the key variables inducing non-convergence and provide physical justifications. For this purpose, this paper proposes a data-driven key variable identification and adjustment method: firstly, based on the blocking cut-set theory and the characteristic that the active unbalanced power ΔP of intermediate power flow exhibits opposite signs at the sending and receiving ends of the cut-set, a blocking cut-set identification method leveraging the characteristics of the active unbalanced power of intermediate power flow is developed; secondly, relying on the feature that the reactive unbalanced power ΔQ of intermediate power flow is less than zero, a key variable identification method based on the characteristics of the reactive unbalanced power of intermediate power flow is presented; finally, a key variable adjustment method grounded in the numerical value of ΔQ is proposed. The validity of the proposed approach was validated via simulated computations using both the IEEE 39 bus system and a practical bulk power system.

  • Open Access

    A Two-Stage Coordinated Frequency Regulation Strategy for Wind Turbines Considering Secondary Frequency Drop and Rotor Speed Recovery

    by Yufei Han, Yibo Zhou, Kexin Li

    The capability of wind turbines (WTs) to provide frequency response is crucial for future power systems with high wind power penetration. Existing strategies primarily focus on mitigating initial and secondary frequency drop (SFD), often overlooking the adverse effects of rotor speed recovery on turbine safety and sustained grid support. Moreover, the lack of a dynamic linkage between the frequency support stage (FSS) and speed recovery stage (SRS) impedes multi-objective coordination encompassing initial drop suppression, SFD mitigation, and rapid rotor speed recovery. To address these gaps, this paper proposes a two-stage coordinated control strategy. In the FSS, the frequency regulation coefficients (Kp and Kd) are adaptively adjusted based on available kinetic energy, ensuring its rational release. Subsequently, the switching timing from FSS to SRS is optimized using these coefficients to suppress the SFD and accelerate recovery. Finally, a fuzzy logic-based PI controller dynamically governs the SRS to restore rotor speed efficiently while further alleviating the SFD. Simulation results confirm the effectiveness of the proposed strategy under two wind speeds. It improves the initial frequency nadir by up to 0.197 Hz over no frequency control, reduces the secondary frequency drop by as much as 0.106 Hz compared to the stepwise method, and accelerates rotor speed recovery by over 30%, quantitatively validating its superior coordinated performance.


  • Open Access

    Prediction of Uncertainty Ramping Demand in New Power Systems Based on a CNN-LSTM Hybrid Neural Network

    by Peng Yu, Zhuang Cai, Hao Zhang, Dai Cui, Hang Zhou, Ruijia Yu, Yibo Zhou

    Under the background of “dual-carbon”, expanding renewable energy grid integration exacerbates grid net load volatility, and system climbing requirements escalate. In this paper, the problem of uncertain ramping demand prediction caused by net load prediction error in new power systems is investigated. First, the total system ramping demand calculation model is constructed, and the effects of deterministic and uncertain ramping demand on the total system ramping demand are analyzed. Secondly, a prediction model based on a CNN-LSTM hybrid neural network is proposed for the uncertain ramp-up demand, which extracts the spatial correlation features of the multi-source influencing factors through the convolutional layer, captures the dynamic evolution law in the time series by using the LSTM layer, and realizes the high-precision point prediction and reliable interval prediction by combining the quantile regression method. Finally, the actual operation data and forecast data of a provincial power grid are used for example verification, and the results show that the proposed model outperformed traditional models (SVM, RF, BPNN) and single deep learning models (CNN, LSTM) in point prediction performance, achieving higher prediction accuracy and validating the effectiveness of the spatio-temporal feature extraction module. In terms of interval prediction quality, compared with the histogram and QRF benchmark models, the proposed model achieves a significant reduction in the average width of the prediction interval, average upward ramp-up demand, and average downward ramp-down demand while maintaining 100% interval coverage. This demand realizes a better balance between prediction economic efficiency and safety, providing more reliable technical support for the precise assessment of uncertain ramp-up demand in new power systems.


  • Open Access

    Analysis on the Influence of the Active Power Recovery Rate on the Transient Stability Margin of a New Power System

    by Yanxin Gu, Yibo Zhou

    With the large-scale integration of wind power, transient stability issues in power systems have become increasingly prominent, among which the impact of the active power recovery rate of wind turbines on system stability cannot be ignored. This paper establishes a sensitivity analytical model between the transient stability index of the system and the active power recovery rate of doubly fed induction generators (DFIGs), revealing the influence of active power recovery rate on system stability. First, the trajectory analysis method is adopted as the transient stability assessment approach, proposing a stability index incorporating accelerating power and transient potential energy. Analytical sensitivity models for synchronous generator accelerating power and transient potential energy to the active power recovery rate of wind turbines are derived in a simplified system. Second, a sensitivity model of the stability margin index to the active power recovery rate is constructed to analyze the influence patterns of the active power recovery rate, initial active power output of wind turbines, and fault duration time on system stability. This research demonstrates that: accelerating the active power recovery rate can restore power balance more quickly but it reduces the rate of transient potential energy variation and delays the peak response of potential energy, thereby decreasing the stability margin; higher initial active power output of wind turbines suppresses the oscillation amplitude of synchronous generators but increases the risk of power imbalance; and prolonged fault duration exacerbates transient energy accumulation and significantly degrades system stability. Additionally, for each 0.1 p.u./s increase in the active power recovery rate of the wind turbine, the absolute value of the stability index of the synchronous machine in the single-machine system decreases by approximately 0.5–1.0, while the sensitivity decreases by approximately 0.01–0.02 s−1. In the multi-machine system, the absolute value of the stability index of the critical machine decreases by approximately 5–10, and the sensitivity decreases by approximately 0.5–1.0 s−1.


  • Open Access

    A Reinforcement Learning-Based Dynamic Network Reconfiguration Strategy Considering the Coordinated Optimization of SOPs and Traditional Switches

    by Yunfei Chu, Rui Zhou, Qimeng Cui, Yong Wang, Boqiang Li, Yibo Zhou

    With the growing integration of renewable sources on a large scale into modern power systems, the operation of distribution networks faces significant challenges under fluctuating renewable energy outputs. Therefore, achieving multi-objective optimization over multiple time periods, including minimizing energy losses and maximizing renewable energy utilization, has become a pressing issue. This paper proposes a Collaborative Intelligent Optimization Reconfiguration Strategy (CIORS) based on a dual-agent framework to achieve a global collaborative optimization of distribution networks in a multi-time period environment. CIORS addresses goal conflicts in multi-objective optimization by designing a collaborative reward mechanism. The discrete agent and continuous agent are responsible for optimizing the switch states within the distribution grid while coordinating the control of both active and reactive power flows through Soft Open Points (SOPs), respectively. To respond to the dynamic fluctuations of loads and renewable energy outputs, CIORS incorporates a dynamic weighting mechanism into the comprehensive reward function, allowing the flexible adjustment of the priority of each optimization objective. Furthermore, CIORS introduces a prioritized experience replay (PER) mechanism, which improves sample utilization efficiency and accelerates model convergence. Simulation results based on an actual distribution network in a specific area demonstrate that CIORS is effective under high-penetration clean energy scenarios.


  • Open Access

    A Diagnosis Method of Power Flow Convergence Failure for Bulk Power Systems Based on Intermediate Iteration Data

    by Gang Mu, Yibo Zhou, Mao Yang, Jiahao Chen

    Power flow calculation is the foundation of security analyses in a power system, and the phenomenon of convergence failure is becoming more prominent with the expansion of the power grid. The existing convergence failure diagnosis methods based on optimization modeling and local feature recognition are no longer viable for bulk power systems. This paper proposes a diagnosis method based on intermediate iteration data and the identification of the transmission power congested channel. Firstly, the transmission power congestion index is constructed, and then a method for identifying transmission congestion channels is proposed. The reasons for convergence failure of the power flow are diagnosed from two aspects: excessive power to be transmitted and insufficient transmission capacity. Finally, with the aim of alleviating transmission channel congestion, a correction strategy for power flow injection space data was constructed, which generates relaxation schemes for operational variables. The effectiveness of the proposed strategy was verified using the simulation results of an actual provincial power grid and a standard example power system with 13,659 buses. The method proposed in this paper is entirely based on intermediate power flow iteration data, which avoids the complex modeling of the power flow adjustment and provides methodological support for power flow diagnosis in bulk power systems.


  • Open Access

    Transient Stability Margin Prediction Under the Concept of Security Region of Power Systems Based on the Long Short-Term Memory Network and Attention Mechanism

    by Jun An, Liang Zhang, Yibo Zhou, Jiachen Yu

    Transient stability prediction under the concept of security region of a power system can be used to identify potential unstable states of the system and ensure its secure operation. In this paper, we propose a method to predict the transient stability margin under the concept of security region based on the long short-term memory (LSTM) network and attention mechanism (AM). This method can ensure rapid and accurate situational awareness of operators in terms of transient stability. The LSTM layer reduces the dimension of the historical steady-state power flow data, and the temporal characteristics are extracted from the data. Subsequently, the AM is introduced to differentiate the characteristics and historical transient stability margin data for the models to identify the information associated with stability. Finally, the LSTM and fully connected layers are used to predict the transient stability margin, providing up-to-date situational awareness of the power system to operators. We performed simulations on the IEEE 39-bus system, and the simulated results validated the effectiveness of the proposed method.