CTChristopher Thompson

Christopher Thompson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher Thompson has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shaping cryogenic 3D volume imaging by pFIB ion species and milling voltage

    by Sanja Sviben, Christopher Thompson, Corinna Braun, Krishnan Venkataraman, Jessica Heebner, Ron Kelley, M. Zuhaib Qayyum, Abhay Kotecha, Ali Khalighifar, Georgios Skiniotis

    Cryogenic plasma focused ion beam-scanning electron microscopy (cryo-pFIB-SEM) enables nanoscale volume imaging of vitrified cells and tissues, but the fidelity of each newly exposed block-face depends on how ions interact with compositionally heterogeneous biological material. Using xenon, argon, oxygen, and nitrogen plasma beams across a 30-2 kV voltage range, we examined how ion species and accelerating voltage influence block-face quality and ultrastructural fidelity. Curtaining imposed a species-dependent lower limit on accelerating voltage, with xenon and argon supporting uniform milling to 10 kV and oxygen and nitrogen to 15 kV. Monte Carlo simulations predicted substantially reduced ion penetration and atomic displacement under these species-specific low-kV conditions. Experimentally, lowering milling voltage suppressed charging and topographic artifacts, with the largest effects observed at heterogeneous interfaces. Oxygen and nitrogen produced greater membrane sharpness and organelle contrast than the noble gases, and these differences influenced machine-learning-based recognition of fine organelle features in 3D datasets. Together, these findings show that cryo-pFIB-SEM image quality cannot be optimized by accelerating voltage or ion species independently. Instead, milling performance reflects a tradeoff among surface fidelity, charging, contrast, and curtaining that depends on local specimen composition. Species-specific low-kV milling therefore provides a practical framework for matching cryo-pFIB-SEM acquisition conditions to the structural and biophysical properties of the biological target.

  • Open Access

    Direct visualization of HIV-1 core nuclear import and its interplay with the nuclear pore

    by Zhen Hou, Stanley Fronik, Yao Shen, Long Chen, Christopher Thompson, Sarah Neumann, Peijun Zhang

    Direct visualization of HIV-1 nuclear import through the nuclear pore complex (NPC) presents a technical challenge due to the rarity of this process. To enable systematic investigation, we developed a robust in situ system that mimics HIV-1 nuclear import in a near-native context using isolated HIV-1 virus like particles (VLP) cores and permeabilized CD4 + T lymphocyte (CEM) cells. This approach supports docking and translocation of abundant viral cores through nuclear pores into the nucleus. For high-resolution visualization, we implemented an integrated correlative approach to guide cryo-focused ion beam (cryo-FIB) milling and cryo-electron tomography (cryo-ET) imaging, enabling precise targeting and structural characterization of individual nuclear import events. Using this workflow, we visualized 510 HIV-1 VLP cores at distinct stages of nuclear import, capturing key snapshots of the full progression of nuclear import. Subsequent statistical and structural analyses allow classification of core morphologies and identification of translocation-associated remodeling in nuclear pores. This work provides a methodological foundation for dissecting HIV-1 and potentially other viruses nuclear import processes and post-entry events in a controlled and quantitative manner.


  • Enhanced Mitochondria-SR Tethering Triggers Adaptive Cardiac Muscle Remodeling

    by Zuzana Nichtová, Celia Fernandez-Sanz, Sergio De La Fuente, Yuexing Yuan, Stephen Hurst, Sebastian Lanvermann, Hui-Ying Tsai, David Weaver, Ariele Baggett, Christopher Thompson, et al.

    Background: Cardiac contractile function requires high energy from mitochondria, and Ca 2+ from the sarcoplasmic reticulum (SR). Via local Ca 2+ transfer at close mitochondria-SR contacts, cardiac excitation feedforward regulates mitochondrial ATP production to match surges in demand (excitation-bioenergetics coupling). However, pathological stresses may cause mitochondrial Ca 2+ overload, excessive reactive oxygen species production and permeability transition, risking homeostatic collapse and myocyte loss. Excitation-bioenergetics coupling involves mitochondria-SR tethers but the role of tethering in cardiac physiology/pathology is debated. Endogenous tether proteins are multifunctional; therefore, nonselective targets to scrutinize interorganelle linkage. Here, we assessed the physiological/pathological relevance of selective chronic enhancement of cardiac mitochondria-SR tethering. Methods: We introduced to mice a cardiac muscle-specific engineered tether (linker) transgene with a fluorescent protein core and deployed 2D/3D electron microscopy, biochemical approaches, fluorescence imaging, in vivo and ex vivo cardiac performance monitoring and stress challenges to characterize the linker phenotype. Results: Expressed in the mature cardiomyocytes, the linker expanded and tightened individual mitochondria-junctional SR contacts; but also evoked a marked remodeling with large dense mitochondrial clusters that excluded dyads. Yet, excitation-bioenergetics coupling remained well-preserved, likely due to more longitudinal mitochondria-dyad contacts and nanotunnelling between mitochondria exposed to junctional SR and those sealed away from junctional SR. Remarkably, the linker decreased female vulnerability to acute massive β-adrenergic stress. It also reduced myocyte death and mitochondrial calcium-overload-associated myocardial impairment in ex vivo ischemia/reperfusion injury. Conclusions: We propose that mitochondria-SR/endoplasmic reticulum contacts operate at a structural optimum. Although acute changes in tethering may cause dysfunction, upon chronic enhancement of contacts from early life, adaptive remodeling of the organelles shifts the system to a new, stable structural optimum. This remodeling balances the individually enhanced mitochondrion-junctional SR crosstalk and excitation-bioenergetics coupling, by increasing the connected mitochondrial pool and, presumably, Ca 2+ /reactive oxygen species capacity, which then improves the resilience to stresses associated with dysregulated hyperactive Ca 2+ signaling.


  • Open Access

    Serial Lift-Out – Sampling the Molecular Anatomy of Whole Organisms

    by Oda Helene Schiøtz, Christoph J.O. Kaiser, Sven Klumpe, Dustin R. Morado, Matthias Poege, Jonathan Schneider, Florian Beck, Christopher Thompson, M. Jürgen Plitzko

    Cryo-focused ion beam milling of frozen-hydrated cells and subsequent cryo-electron tomography (cryo-ET) has enabled the structural elucidation of macromolecular complexes directly inside cells. Application of the technique to multicellular organisms and tissues, however, is still limited by sample preparation. While high-pressure freezing enables the vitrification of thicker samples, it prolongs subsequent preparation due to increased thinning times and the need for extraction procedures. Additionally, thinning removes large portions of the specimen, restricting the imageable volume to the thickness of the final lamella, typically < 300 nm. Here, we introduce Serial Lift-Out, an enhanced lift-out technique that increases throughput and obtainable contextual information by preparing multiple sections from single transfers. We apply Serial Lift-Out to C. elegans L1 larvae yielding a cryo-ET dataset sampling the worm’s anterior-posterior axis and resolve its ribosome structure to 7 Å, illustrating how Serial Lift-Out enables the study of multicellular molecular anatomy.