Vidhya Maney Surendran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vidhya Maney Surendran has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chandramathy Irulappan
Department of Architecture, Thiagarajar College of Engineering, Madurai, Tamil Nadu, India
1 shared publication - Manisha Gotmare
Gotmare and Associates
1 shared publication - N. S. Nalini
Professor, Dayananda Sagar College of Architecture, DSI Campus, Shavige Malleswara Hills, Kumaraswamy Layout, Bengaluru 560078, Karnataka, India
1 shared publication - Nishi Sudesh Sukthankar
M.Arch Student, Dayananda Sagar College of Architecture, DSI Campus, Shavige Malleswara Hills, Kumaraswamy Layout, Bengaluru 560078, Karnataka, India
1 shared publication Rama R. Subrahmanian
Professor, Dayananda Sagar College of Architecture, DSI Campus, Shavige Malleswara Hills, Kumaraswamy Layout, Bengaluru 560078, Karnataka, India
1 shared publication- Ramalingam Velraj
Institute for Energy Studies, Anna University, Chennai, India
1 shared publication
Latest Publications
- Open Access
- 10 July 2026
- Published by Granthaalayah Publications and Printers in ShodhSamajik: Journal of Social Studies
- Vol. 3 (2) , 147-158
ASSESSING THE OPPORTUNITIES FOR ADAPTIVE REUSE AND TOURISM DEVELOPMENT OF COURTYARD HOUSES WITHIN THE TEMPLE PRECINCT OF KAVLEM, GOA
This study aims to evaluate the structural conditions, social perspectives, and adaptive reuse potential of two historic courtyard houses in Kavlem, Goa. The study adopts a mixed-methods approach, combining spatial documentation, stakeholder interviews, people's perceptual surveys, and expert consultations with structural engineers. On-site audits, plan analysis, and photographic documentation were used to analyze two case houses: Dubashi and Gaitonde. A reuse-readiness matrix was created, and intervention techniques were suggested based on condition, cultural alignment, and community feedback. Among the two century-old courtyard houses, the structurally sound Dubashi house is deemed suitable for limited cultural use after minor repairs as per all the surveyed architects and engineers. All interviewed respondents indicate that traditional Goan courtyard houses can be adapted with minimal intervention if done sensitively. In comparison, the more fragile Gaitonde home requires considerable structural restoration before usage, with 75% of specialists citing difficulties such as foundation erosion, timber rot, and roof instability as prevalent vulnerabilities that require major intervention. According to community surveys, 94% of respondents support the preservation of these properties, while 59% prefer adaptive reuse for culturally relevant, non-commercial activities such as museums, cultural art shows, or spiritual places.
- 10 July 2026
- Published by Granthaalayah Publications and Printers in ShodhSamajik: Journal of Social Studies
- Vol. 3 (2) , 147-158
Open AccessASSESSING THE OPPORTUNITIES FOR ADAPTIVE REUSE AND TOURISM DEVELOPMENT OF COURTYARD HOUSES WITHIN THE TEMPLE PRECINCT OF KAVLEM, GOA
This study aims to evaluate the structural conditions, social perspectives, and adaptive reuse potential of two historic courtyard houses in Kavlem, Goa. The study adopts a mixed-methods approach, combining spatial documentation, stakeholder interviews, people's perceptual surveys, and expert consultations with structural engineers. On-site audits, plan analysis, and photographic documentation were used to analyze two case houses: Dubashi and Gaitonde. A reuse-readiness matrix was created, and intervention techniques were suggested based on condition, cultural alignment, and community feedback. Among the two century-old courtyard houses, the structurally sound Dubashi house is deemed suitable for limited cultural use after minor repairs as per all the surveyed architects and engineers. All interviewed respondents indicate that traditional Goan courtyard houses can be adapted with minimal intervention if done sensitively. In comparison, the more fragile Gaitonde home requires considerable structural restoration before usage, with 75% of specialists citing difficulties such as foundation erosion, timber rot, and roof instability as prevalent vulnerabilities that require major intervention. According to community surveys, 94% of respondents support the preservation of these properties, while 59% prefer adaptive reuse for culturally relevant, non-commercial activities such as museums, cultural art shows, or spiritual places.
- 6 July 2024
- Published by Springer Nature
- p. 289-296
Analysis of Energy Conservation Measures for Existing Residential Apartments in a Composite Climate
- 6 July 2024
- Published by Springer Nature
- p. 289-296
Analysis of Energy Conservation Measures for Existing Residential Apartments in a Composite Climate
- Open Access
Thermal Performance Assessment of Envelope Retrofits for Existing School Buildings in a Hot–Humid Climate: A Case Study in Chennai, India
This study aims to propose building envelope retrofit packages for existing naturally ventilated school buildings in the hot–humid climatic region of Chennai, India. Indoor thermal parameters were collected through field studies from nine sample classrooms of a selected school building in May 2019, between 9.00 am and 4.00 pm. The thermal performance assessment of the existing building was performed by examining the discomfort hours using the CBE thermal comfort tool. Envelope retrofit strategies gathered from the literature and building standards were applied and studied through simulation. The findings reveal the enormous potential to increase the thermal comfort of existing school buildings through envelope retrofit measures. The results demonstrate that the whole-building temperature can be reduced up to 3.2 °C in summer and up to 3.4 °C in winter. Implementing retrofit measures to the building envelopes of existing buildings will help school owners to increase the comfortable hours of whole buildings by up to 17%. In comparison, annual energy savings of up to 13% for the whole building can be made by enhancing the thermal performance of the building envelope. The findings will also help architects to optimise thermal performance and energy usage with minimal interventions.
Open AccessThermal Performance Assessment of Envelope Retrofits for Existing School Buildings in a Hot–Humid Climate: A Case Study in Chennai, India
This study aims to propose building envelope retrofit packages for existing naturally ventilated school buildings in the hot–humid climatic region of Chennai, India. Indoor thermal parameters were collected through field studies from nine sample classrooms of a selected school building in May 2019, between 9.00 am and 4.00 pm. The thermal performance assessment of the existing building was performed by examining the discomfort hours using the CBE thermal comfort tool. Envelope retrofit strategies gathered from the literature and building standards were applied and studied through simulation. The findings reveal the enormous potential to increase the thermal comfort of existing school buildings through envelope retrofit measures. The results demonstrate that the whole-building temperature can be reduced up to 3.2 °C in summer and up to 3.4 °C in winter. Implementing retrofit measures to the building envelopes of existing buildings will help school owners to increase the comfortable hours of whole buildings by up to 17%. In comparison, annual energy savings of up to 13% for the whole building can be made by enhancing the thermal performance of the building envelope. The findings will also help architects to optimise thermal performance and energy usage with minimal interventions.