JGJeevan Prakash Ms Gopal

Jeevan Prakash Ms Gopal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeevan Prakash Ms Gopal has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Angela Bsc Summers

    Department of Renal and Pancreas Transplantation, Manchester University Hospitals NHS Foundation Trust, Manchester Royal Infirmary, Manchester, United Kingdom

    1 shared publication
  • Brian Mba Lock

    Moor Instruments Ltd, Axminster, United Kingdom

    1 shared publication
  • David Md van Dellen

    Department of Renal and Pancreas Transplantation, Manchester University Hospitals NHS Foundation Trust, Manchester Royal Infirmary, Manchester, United Kingdom

    1 shared publication
  • Harry Bsc Spiers

    Department of Transplantation, Addenbrooke’s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom

    1 shared publication
  • Matthew A. Mres Goldsworthy

    Department of Renal and Pancreas Transplantation, Manchester University Hospitals NHS Foundation Trust, Manchester Royal Infirmary, Manchester, United Kingdom

    1 shared publication
  • Osborne Ms Vaz

    Department of Renal and Pancreas Transplantation, Manchester University Hospitals NHS Foundation Trust, Manchester Royal Infirmary, Manchester, United Kingdom

    1 shared publication

Latest Publications

  • Open Access

    Using Laser Speckle Contrast Imaging to Quantify Perfusion Quality in Kidney and Pancreas Grafts on Vascular Reperfusion: A Proof-of-Principle Study

    by Jeevan Prakash Ms Gopal, Osborne Ms Vaz, Rebecca Msc Varley, Harry Bsc Spiers, Matthew A. Mres Goldsworthy, Vishwanath Ms Siddagangaiah, Brian Mba Lock, Videha PhD Sharma, Angela Bsc Summers, Zia PhD Moinuddin, et al.

    Introduction. The accuracy of intraoperative graft perfusion assessment still remains subjective, with doppler examination being the only objective adjunct. Laser speckle contrast imaging (LSCI) has been used to assess intraoperative blood flow in neurosurgery and in various surgical specialties. Despite its ability to accurately quantify perfusion at the microvascular level, it has not been clinically evaluated in kidney/kidney-pancreas transplantation for perfusion characterization. We aimed to evaluate the utility of LSCI and identify objective parameters that can be quantified at reperfusion. Methods. This study was registered in ClinicalTrials.gov (NCT04202237). The Moor FLPI-2 blood flow imager was used in 4 patients (1 Simultaneous Pancreas and Kidney, 2 deceased, and 1 living donor kidney transplants) during reperfusion to capture reperfusion data. The following parameters were measured: flux (average speed × concentration of moving red blood cells in the sample volume), doppler centroid, total and valid pixels, valid rate, and total and valid area. Flux data were analyzed with Moor FLPI analysis software. Results. The perfusion characteristics and flux images correlated with initial graft function. Conclusions. LSCI is a safe, noncontact imaging modality that provides real-time, accurate, high-resolution, full field blood flow images and a wide range of flux data to objectively quantify organ reperfusion intraoperatively in kidney/kidney-pancreas transplantation. This modality could be used to develop a robust numerical quantification system for the evaluation and reporting of intraoperative organ perfusion, and aid intraoperative decision-making. Perfusion data could be combined with biomarkers and immunological parameters to more accurately predict graft outcomes. Export